Fault location determination in three-terminal transmission lines connected to industrial microgrids without requiring fault classification data and independent of line parameters

被引:14
|
作者
Abasi, Mahyar [1 ]
Rohani, Arash [2 ]
Hatami, Farhad [1 ]
Joorabian, Mahmood [1 ]
Gharehpetian, Gevork B. [3 ]
机构
[1] Shahid Chamran Univ Ahvaz, Dept Elect Engn, Fac Engn, Ahvaz, Iran
[2] Khuzestan Reg Elect Co KZREC, Ahvaz, Iran
[3] Amirkabir Univ Technol, Dept Elect Engn, Tehran, Iran
关键词
Fault location; Industrial microgrids; Renewable energy; Three-terminal lines; Voltage and current phasors; PMU; SYNCHRONIZED VOLTAGE; DISTRIBUTION NETWORK; RELAYS; SYSTEM;
D O I
10.1016/j.ijepes.2021.107044
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The connection of large industrial microgrids to three-terminal transmission lines greatly complicates the protection scheme of the lines due to the uncertainty in generating renewable energy sources, the probability of unintentional islanding, the abrupt switching of sensitive and critical loads, the influence of supply and demand management programs, and bidirectional active and reactive power flow. This paper presents a fault location algorithm for three-terminal transmission lines connected to an industrial microgrid that does not need the detection of faulty section, fault classification, and transmission line parameters. The proposed method uses voltage and current phasors of transmission lines measured by phasor measurement units (PMUs). One of the salient features of the proposed algorithm is that it does not need to determine the faulty section before the fault location operation. Furthermore, since power transmission lines are always exposed to changing climatic conditions and aging, their electrical characteristics vary over time in the long run compared to their rated value. Hence, this leads to the malfunction of protection schemes. This is solved in this study as the proposed fault location algorithm is independent of line impedances. On the other hand, the dependence of conventional fault location algorithms on fault classification data reduces the reliability of fault location schemes, making these algorithms dependent on fault classification data. However, the present study overcomes this problem as the algorithm is independent of the data of the faulty phase(s) detection. The proposed scheme is fully implemented in the MATLAB software environment, and the performance of the algorithm is analyzed for various fault types under different conditions. The validity of the algorithm is shown by various tests and sensitivity analyses.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Transient-Based Fault Location on Three-Terminal and Tapped Transmission Lines Not Requiring Line Parameters
    Davoudi, Masoud
    Sadeh, Javad
    Kamyab, Ebadollah
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (01) : 179 - 188
  • [2] Multiple Fault Location in Three-Terminal Transmission Lines
    Ariakia, Hadi
    Emami, Kianoush
    Fernando, Tyrone
    Iu, Herbert
    [J]. IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 345 - 350
  • [3] A new scheme for fault location of three-terminal parallel transmission lines without transposer
    Chen, Gonggui
    Cai, Daiying
    Long, Hongyu
    Long, Yi
    Zeng, Xianjun
    Zhou, Ping
    Kang, Peng
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (17) : 2473 - 2487
  • [4] Transmission Line Fault Location Algorithms Without Requiring Line Parameters
    Liao, Yuan
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2008, 36 (11) : 1218 - 1225
  • [5] Setting Free Fault Location for Three-Terminal Hybrid Transmission Lines Connected With Conventional and Renewable Resources
    Likhitha, Kukkala
    Naidu, O. D.
    [J]. IEEE ACCESS, 2023, 11 : 23839 - 23856
  • [6] New fault location scheme for three-terminal untransposed parallel transmission lines
    Saber, Ahmed
    Emam, Ahmed
    Elghazaly, Hany
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2018, 154 : 266 - 275
  • [7] A new technique, based on voltages, for fault location on three-terminal transmission lines
    Minambres, JF
    Zamora, I
    Mazon, AJ
    Zorrozua, MA
    AlvarezIsasi, R
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1996, 37 (02) : 143 - 151
  • [8] Synchrophasor Based Novel Fault Location Algorithm for Three-Terminal Transmission Line
    Sontakke, Maitreyee
    Hinge, Trupti
    Dambhare, Sanjay
    [J]. HELIX, 2020, 10 (02): : 9 - 14
  • [9] Research on a fault location method for a hybrid three-terminal DC transmission line
    Gao, Shuping
    Jiang, Yuanyue
    Song, Guobing
    Gao, Yue
    Zeng, Zixuan
    [J]. Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (15): : 76 - 83
  • [10] Fast & adaptive fault location technique for three-terminal lines
    Sardari, H.
    Mozafari, B.
    Shayanfar, H. A.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2020, 179