Reduction in plate strain by addition of an intramedullary pin

被引:106
|
作者
Hulse, D [1 ]
Hyman, W
Nori, M
Slater, M
机构
[1] Texas A&M Univ, Coll Vet Med, Dept Small Anim Med & Surg, College Stn, TX 77843 USA
[2] Texas A&M Univ, Coll Vet Med, Dept Vet Anat & Publ Hlth, College Stn, TX 77843 USA
[3] Texas A&M Univ, Bioengn Program, College Stn, TX 77843 USA
关键词
D O I
10.1111/j.1532-950X.1997.tb00516.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-The purpose of this study was to determine the strain sparing effect of a bone plate and rod system compared with a bone plate alone. Study Design-Mathematical analysis and in vitro modeling of implant-bone constructs. Implants were instrumented with uniaxial strain gauges. Animals or Sample Preparation-Five pairs of canine femurs. Methods-Bone plates were instrumented with two 350-ohm strain gauges. The bone plates were used to bridge a simulated fracture gap in five pairs of canine femurs. In one femur of each pair, a bone plate alone was used to bridge the gap; in the opposite femur, a bone plate and intramedullary rod combination was used. Each specimen was mounted on a custom jig and loaded in an axial servohydraulic testing machine. A constantly increasing compressive load was applied at the rate of 0.7 cm/sec. Strains at 400.5 N were recorded and analyzed using Wilcoxon's signed rank test. Mathematical modeling was done using parallel beam theory. Results-Stress reduction in the plate and rod system was twofold compared with the plate alone (P = .059). As important, based on stress reduction in the plate, the fatigue Life of the plate/rod system increased 10-fold over the plate system alone and was greater than 10-fold at higher absolute stress values. Mathematical analysis of the plate/rod system was similar to that seen with the in vitro analysis. Conclusions-The combination of a bone plate and intramedullary pin was superior in reducing plate stress when compared with the plate alone and functioned as two beams acting in concert. Clinical Relevance-Stabilization of comminuted fractures by bridging the zone of fragmentation with a bone plate without anatomic reduction of each fragment is a useful method of managing this type of injury. Addition of an intramedullary pin reduces the stress applied to the plate and thereby extends the fatigue Life of the bone (C) Copyright 1997 by The American College of Veterinary Surgeons.
引用
收藏
页码:451 / 459
页数:9
相关论文
共 50 条
  • [1] Effect of intramedullary pin size on reducing bone plate strain
    Hulse, D
    Ferry, K
    Fawcett, A
    Gentry, D
    Hyman, W
    Geller, S
    Slater, M
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2000, 13 (04) : 185 - 190
  • [2] The effect of intramedullary pin size and plate working length on plate strain in locking compression platerod constructs under axial load
    Pearson, Tim
    Glyde, Mark R.
    Day, Robert E.
    Hosgood, Giselle L.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (06) : 451 - 458
  • [3] Midshaft clavicular fractures: comparison of intramedullary pin and plate fixation
    Kleweno, Conor P.
    Jawa, Andrew
    Wells, Jessica H.
    O'Brien, Travis G.
    Higgins, Laurence D.
    Harris, Mitchel B.
    Warner, Jon J. P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (07) : 1114 - 1117
  • [4] HEALING OF MANDIBULAR BODY OSTEOTOMIES AFTER PLATE AND INTRAMEDULLARY PIN FIXATION
    ROUSH, JK
    WILSON, JW
    VETERINARY SURGERY, 1989, 18 (03) : 190 - 196
  • [5] INTRAMEDULLARY SUPRAMID PIN AND PLATE-SCREW FIXATION FOR FRACTURE OF HUMERUS
    NUMMI, P
    ACTA CHIRURGICA SCANDINAVICA, 1975, 141 (01): : 48 - 52
  • [6] Reduction and fixation of radius neck fractures in children with intramedullary pin
    Ugutmen, Ender
    Ozkan, Korhan
    Ozkan, Feyza Unlu
    Eceviz, Engin
    Altintas, Faik
    Unay, Koray
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2010, 19 (04): : 289 - 293
  • [7] An in vitro biomechanical comparison of a prototype intramedullary pin-plate with a dynamic compression plate for equine metacarpophalangeal arthrodesis
    Sod, GA
    Martin, GS
    VETERINARY SURGERY, 2004, 33 (01) : 83 - 91
  • [8] Distal Normograde Intramedullary Pin and Locking Plate Placement in the Canine Humerus: A Cadaveric Study
    Pearson, Tim
    Glyde, Mark
    Hosgood, Giselle
    Beierer, Lucas
    VETERINARY SURGERY, 2016, 45 (07) : 879 - 886
  • [9] PNEUMATIC INTRAMEDULLARY PIN SHEAR
    MCCURNIN, DM
    VETERINARY MEDICINE & SMALL ANIMAL CLINICIAN, 1976, 71 (10): : 1423 - 1425
  • [10] In vitro mechanical evaluation on the use of an intramedullary pin-plate combination for pantarsal arthrodesis in dogs
    Kirsch, JA
    Déjardin, LM
    DeCamp, CE
    Meyer, EG
    Haut, RC
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2005, 66 (01) : 125 - 131