A comparison of three ionization chambers for IMRT patient specific quality assurance

被引:1
|
作者
Fraser, D [1 ]
Seuntjens, J [1 ]
Parker, W [1 ]
机构
[1] McGill Univ, Montreal, PQ, Canada
关键词
D O I
10.1118/1.1998677
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare fifty IMRT patient specific point dose measurements between three thimble‐type ionization chambers of varying volumes, and with dose calculations from a commercial treatment planning system (TPS). Method and Materials: Fifty patient plans were recomputed with unmodified fluence patterns on three separate CT image sets of a 30×30×17 cm3 solid water phantom and three different ionization chambers: 0.6 cm3 NE 2571 Farmer; 0.125 cm3 Wellhofer IC10; and 0.015 cm3 PTW Freiburg 31006 PinPoint. Dose volume statistics were generated by the TPS over outlined chamber volumes, as seen on the scans. The phantom and chamber were set up on the treatment couch and irradiated as would have been for one patient's fraction. IMRT measurement reproducibility, and the TPS dose calculation accuracy under reference conditions was evaluated. Chamber‐type to chamber‐type differences, as well as differences between measured and treatment planning dose calculations were compared. Results: The PinPoint chamber experienced the most inferior reproducibility (3.57%) as well the greatest discrepancy from the dose calculation of the TPS. For the same delivery, chamber‐type to chamber‐type response can vary by up to 8%. The average of the ratios of PinPoint‐to‐NE2571 and IC10‐to‐NE2571 measured absorbed dose to water, for 50 IMRT plans, amounts to 1.023 ± 0.005 and 1.007± 0.003, respectively. The corrected ionization measurement and TPS dose in IMRT fields were normalized to the values in reference conditions, i.e., we compared [formula omitted] with [formula omitted]. The mean ratios of [formula omitted] for the PinPoint, IC10, and NE2571 are 0.933, 0.940, and 0.948 respectively, illustrating a 6% difference in TPS predicted chamber dose and measured signal Conclusion: The chamber‐type‐to‐chamber‐type dose measurement variation is systematic for the dosimeters used. The application of the absorbed dose to water calibration coefficient, which was determined under reference conditions may not hold in IMRT fields, whose specific characteristics are not known. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2166 / 2166
页数:1
相关论文
共 50 条
  • [1] RapidArc Patient Specific Quality Assurance: Comparison with DMLC IMRT
    Popple, R.
    Brezovich, I.
    Duan, J.
    Shen, S.
    Wu, X.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Characterization of cylindrical ionization chambers for patient specific IMRT QA
    Fraser, Danielle
    Parker, William
    Seuntjens, Jan
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04): : 241 - 251
  • [3] CTRC Experience: Patient Specific IMRT Quality Assurance with Ionization Chamber and Detector Arrays
    Cruz, W.
    Stathakis, S.
    Mavroidis, P.
    Esquivel, C.
    Papanikolaou, N.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Evaluation of ionization chambers for quality assurance
    Kim, CS
    Kim, CY
    Choi, MS
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 508 - 510
  • [5] Patient specific IMRT quality assurance with film, ionization chamber and detector arrays: Our institutional experience
    Cruz, Wilbert
    Narayanasamy, Ganesh
    Regan, Morgan
    Mavroidis, Panayiotis
    Papanikolaou, Niko
    Ha, Chul S.
    Stathakis, Sotirios
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2015, 115 : 12 - 16
  • [6] National survey of patient specific IMRT quality assurance in China
    Pan, Yuxi
    Yang, Ruijie
    Zhang, Shuming
    Li, Jiaqi
    Dai, Jianrong
    Wang, Junjie
    Cai, Jing
    [J]. RADIATION ONCOLOGY, 2019, 14 (1)
  • [7] National Survey of Patient Specific IMRT Quality Assurance in China
    Pan, Y.
    Yang, R.
    Dai, J.
    Cai, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E177 - E177
  • [8] National survey of patient specific IMRT quality assurance in China
    Yuxi Pan
    Ruijie Yang
    Shuming Zhang
    Jiaqi Li
    Jianrong Dai
    Junjie Wang
    Jing Cai
    [J]. Radiation Oncology, 14
  • [9] Patient-specific quality assurance for IMRT delivery: A multicentre study
    Hizam, Diyana Afrina
    Jong, Wei Loong
    Zin, Hafiz Mohd
    Ng, Kwan Hoong
    Ung, Ngie Min
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2023, 209
  • [10] Survey of patient-specific quality assurance practice for IMRT and VMAT
    Chan, Gordon H.
    Chin, Lee C. L.
    Abdellatif, Ady
    Bissonnette, Jean-Pierre
    Buckley, Lesley
    Comsa, Daria
    Granville, Dal
    King, Jenna
    Rapley, Patrick L.
    Vandermeer, Aaron
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 155 - 164