Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study

被引:8
|
作者
Erdem, Mehmet [1 ]
Gulabi, Deniz [2 ]
Cecen, Gultekin Sitki [2 ]
Avci, Cem Coskun [3 ]
Asci, Murat [4 ]
Saglam, Fevzi [2 ]
机构
[1] Sakarya Univ, Orthopaed & Traumatol Dept, Fac Med, Sakarya, Turkey
[2] Dr Lutfi Kirdar Kartal Training & Res Hosp, TR-34890 Istanbul, Turkey
[3] Umraniye Training & Res Hosp, Istanbul, Turkey
[4] Tokat State Hosp, Tokat, Turkey
关键词
Knee; Knee prothesis; Alignment; Fibula; CONVENTIONAL TKA; POSTERIOR SLOPE; EXTRAMEDULLARY; REPLACEMENT; NAVIGATION; GUIDES; INSTRUMENTATION; INTRAMEDULLARY; POSITION; SURGERY;
D O I
10.1007/s00167-014-2957-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One of the important factors in a successful arthroplasty is component alignment. The primary objective of this study was to determine whether the fibular shaft reference technique is beneficial for the tibial component position on the postoperative plain radiograph after total knee arthroplasty. A total of 42 patients between 2009 and 2011 were analysed retrospectively. The surgeon prepared the tibia using an extramedullary cutting guide and set the posterior tibial slope with respect to the fibular reference rod. In the postoperative radiographic measurements, a true anteroposterior and lateral radiograph of the lower leg covering the whole length of the tibia was used. Five patients were excluded as they did not meet the inclusion criteria, four patients were excluded due to improper radiographs and the study group was reduced to 33 patients and 35 knees. The mean preoperative tibiofibular angle was 2.1A degrees A A +/- A 0.8A degrees. The mean postoperative tibial sagittal angle measurements were 83.3A degrees A A +/- A 1.4A degrees (81A degrees-86A degrees). 33 (94 %) Knees gained the desired tibial sagittal angle within the desired alignment (5A degrees A A +/- A 3A degrees). The mean postoperative tibial coronal angle was 89.3A degrees A A +/- A 1.5A degrees. The tibial component coronal angle of two knees was more than 3 alignment from the neutral mechanical axis. The major clinical relevance of the technique described in the present study is cost-effectiveness, and it does not require any extra time or surgical equipment. This method can be used as an alternative choice for bulky extremities which is a cause of malalignment of the components. Retrospective case series, Level IV.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 50 条
  • [1] Using fibula as a reference can be beneficial for the tibial component alignment after total knee arthroplasty, a retrospective study
    Mehmet Erdem
    Deniz Gulabi
    Gultekin Sitki Cecen
    Cem Coskun Avci
    Murat Asci
    Fevzi Saglam
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 2068 - 2073
  • [2] Rotational alignment of the tibial component in total knee arthroplasty
    Bindelglass, DF
    ORTHOPEDICS, 2001, 24 (11) : 1049 - 1052
  • [3] Improving tibial component alignment in total knee arthroplasty
    G. Cinotti
    P. Sessa
    A. D’Arino
    F. R. Ripani
    G. Giannicola
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 3563 - 3570
  • [4] Rotational alignment of the tibial component in total knee arthroplasty
    Indelli, Pier Francesco
    Graceffa, Angelo
    Marcucci, Massimiliano
    Baldini, Andrea
    ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (01)
  • [5] Improving tibial component alignment in total knee arthroplasty
    Cinotti, G.
    Sessa, P.
    D'Arino, A.
    Ripani, F. R.
    Giannicola, G.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3563 - 3570
  • [6] Revisiting the tibial crest as reference for the mechanical alignment of the tibial component in total knee arthroplasty: a cadaveric study on Caucasian tibiae
    Cinotti G.
    Ripani F.R.
    Sinno E.
    Sarti S.
    LaTorre G.
    Giannicola G.
    MUSCULOSKELETAL SURGERY, 2021, 105 (2) : 161 - 166
  • [7] Varus/valgus alignment of the tibial component in total knee arthroplasty
    Jeffcote, B
    Shakespeare, D
    KNEE, 2003, 10 (03): : 243 - 247
  • [8] Tibial Component Alignment After Total Knee Arthroplasty with Intramedullary Instrumentation: A Prospective Analysis
    Talmo, Carl T.
    Cooper, Andrew J.
    Wuerz, Tom
    Lang, Jason E.
    Bono, James V.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08): : 1209 - 1215
  • [9] ALIGNMENT OF TOTAL KNEE ARTHROPLASTY - THE RELATIONSHIP TO RADIOLUCENCY AROUND THE TIBIAL COMPONENT
    HARVEY, IA
    MANNING, MP
    SAMPATH, SAC
    JOHNSON, R
    ELLOY, MA
    MEDICAL ENGINEERING & PHYSICS, 1995, 17 (03) : 182 - 187
  • [10] Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty
    Dong-Hoon Lee
    Jai-Gon Seo
    Young-Wan Moon
    International Orthopaedics, 2008, 32 : 223 - 227