Remote Imaging Capture with Widefield Swept-Source OCT Angiography During the COVID-19 Pandemic

被引:0
|
作者
Garg, Itika [1 ,2 ]
Katz, Raviv [1 ]
Lu, Yifan [1 ,2 ]
Miller, John B. [1 ,2 ]
机构
[1] Harvard Retinal Imaging Lab, Boston, MA 02138 USA
[2] Massachusetts Eye & Ear Infirm, Retina Serv, Boston, MA 02114 USA
来源
CLINICAL OPHTHALMOLOGY | 2022年 / 16卷
关键词
COVID-19; COVID; teleophthalmology; remote imaging; teleimaging; telemedicine; optical coherence tomography angiography; retinal imaging; optical coherence tomography; HAND-HELD; OUTBREAK;
D O I
10.2147/OPTH.S352503
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The COVID-19 pandemic has had a widespread impact on the health sector worldwide, both in the clinical and research subsector. This has necessitated for the invention of protocols compliant with social distancing policies to efficiently tackle the current needs. Our aim is to describe a novel remote imaging technique, which helped us continue our research with widefield swept-source optical coherence tomography angiography (WF SS-OCTA). Patients and Methods: As a part of this cross-sectional observational study from August 2020 to September 2020 at Massachusetts Eye and Ear (MEE), we used our institute approved remote desktop, outside of MEE, to gain full access to the on-site WF SS-OCTA device in the imaging room for the purpose of remote imaging. With only the patient being in the imaging room, effective communication was established via video conferencing on an encrypted tablet computer device for the entire procedure. Results: We imaged four patients with various retinal pathologies, aged 32-69 years. All images obtained were of high quality and signal strength (median score 9/10 for both) and all patients reported a highly satisfactory, comfortable, and safe experience amidst the COVID-19 pandemic. Conclusion: This novel method is better for remote imaging compared to the previously described techniques as it is time and cost effective, requires limited resources without compromising the image quality or patient satisfaction and adheres to the various guidelines for infection control, most importantly social distancing. As a paradigm shift, this can also be employed in future for setups with limited staff like busy emergency departments or a rural setup with limited access or difficult commute, in the "newnormal" era.
引用
收藏
页码:477 / 486
页数:10
相关论文
共 50 条
  • [1] High-speed and widefield handheld swept-source OCT angiography with a VCSEL light source
    Ni, Shuibin
    Wei, Xiang
    Ng, Ringo
    Ostmo, Susan
    Chiang, Michael F.
    Huang, David
    Jia, Yali
    Campbell, J. Peter
    Jian, Yifan
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (06) : 3553 - 3570
  • [2] In Vivo Mapping of the Choriocapillaris in Healthy Eyes A Widefield Swept-Source OCT Angiography Study
    Borrelli, Enrico
    Uji, Akihito
    Toto, Lisa
    Viggiano, Pasquale
    Evangelista, Federica
    Mastropasqua, Rodolfo
    OPHTHALMOLOGY RETINA, 2019, 3 (11): : 979 - 984
  • [3] A clinical MHz swept-source OCT prototype for ultra-widefield imaging
    Matten, Philipp
    Niederleithner, Michael
    Britten, Anja
    Hugang, Ren
    Arain, Muzammil
    Bello, Simon Antonio
    Salas, Matthias
    Ginner, Laurin
    Drexler, Wolfgang
    Leitgeb, Rainer A.
    Schmoll, Tilman
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (09)
  • [4] Ultra-widefield handheld swept-source OCT for peripheral retinal imaging
    Ni, Shuibin
    Nguyen, Thanh-Tin P.
    Ng, Ringo
    Khan, Shanjida
    Ostmo, Susan
    Jia, Yali
    Chiang, Michael F.
    Huang, David
    Campbell, J. Peter
    Jian, Yifan
    OPHTHALMIC TECHNOLOGIES XXXII, 2022, 11941
  • [5] Swept-source OCT and swept-source OCT angiography in glaucoma diagnostics; [Swept-Source-OCT und Swept-Source-OCT-Angiographie in der Glaukomdiagnostik]
    Kremmer S.
    Smok C.
    Anastassiou G.
    Spektrum der Augenheilkunde, 2017, 31 (6) : 269 - 287
  • [6] Widefield Swept-Source Optical Coherence Tomography Angiography
    Shahidzadeh, Anoush
    Kim, Alice Yon
    Aziz, Hassan A.
    Durbin, Mary K.
    Puliafito, Carmen A.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [7] Swept-Source OCT and Swept-Source OCT Angiography before and after Vitrectomy with Stuffing of the Optic Pit
    Michalewska, Zofia
    Nawrocka, Zofia
    Nawrocki, Jerzy
    OPHTHALMOLOGY RETINA, 2020, 4 (09): : 927 - 937
  • [8] Swept-Source OCT Angiography of Serpiginous Choroiditis
    Pakzad-Vaezi, Kaivon
    Khaksari, Kosar
    Chu, Zhongdi
    Van Gelder, Russell N.
    Wang, Ruikang K.
    Pepple, Kathryn L.
    OPHTHALMOLOGY RETINA, 2018, 2 (07): : 712 - 719
  • [9] MHz Swept-Source OCT Angiography of the choriocapillaris
    Schmoll, Tilman
    Niederleithner, Michael
    Ren, Hugang
    Arain, Muzammi Arshad
    Williams, Rick
    Salas, Matthias
    Ginner, Laurin
    Drexler, Wolfgang
    Leitgeb, Rainer A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [10] Morphometrical Evaluation of Choriocapillaris using Widefield Swept-Source OCT Angiography in Early and Intermediate AMD
    Douglas, Vivian Paraskevi
    Bannai, Deepthi
    Cui, Ying
    Douglas, Konstantinos A. A.
    Nigalye, Archana
    Katz, Raviv
    Lains, Ines
    Zhu, Ying
    Le, Rongrong
    Lu, Yifan
    Zeng, Rebecca
    Kim, Ivana K.
    Vavvas, Demetrios
    Miller, Joan
    Husain, Deeba
    Miller, John
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (09)