Differences in heart valve procedures between North American and European centers: A report from the Artificial Valve Endocarditis Reduction Trial (AVERT)

被引:0
|
作者
Englberger, L
Carrel, T
Schaff, HV
Kennard, ED
Holubkov, R
机构
[1] Univ Hosp Bern, Inselspital, Dept Cardiovasc Surg, CH-3010 Bern, Switzerland
[2] Univ Pittsburgh, AVERT Coordinating Ctr, Pittsburgh, PA USA
[3] Univ Pittsburgh, Pittsburgh, PA USA
来源
JOURNAL OF HEART VALVE DISEASE | 2001年 / 10卷 / 05期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Differences in heart valve procedures between North American (NA) and European (EU) centers were evaluated in a multicenter trial. Methods: Between July 1998 and January 2000, 807 patients from 12 NA (n = 446) and seven EU centers (n = 361) were randomized to receive either Silzone (R) or conventional valves in the Artificial Valve Endocarditis Reduction Trial (AVERT). Subanalysis was performed to compare demographics, patient risk profile, surgical techniques and perioperative management of patients in NA and EU centers. Results: Mean age was significantly younger and body mass index higher in NA. Patients' risk profiles showed significantly higher incidences of previous myocardial infarction, congestive heart failure, angina, prior cardiovascular surgery, and history of smoking in NA. A different distribution of implant position was observed between groups: aortic valve/mitral valve/double valve replacement in 54.0, 35.7 and 10.3% in NA, and 64.5, 27.4 and 8.0% in EU (p <0.01). Concomitant coronary artery bypass grafting was performed in 31.6% of NA patients and 19.4% of EU patients (p <0.001). Timing of surgery showed a higher incidence of urgent procedures in NA centers. Distribution of valve sizes and perioperative complication rate were similar, but length of hospital stay was longer in EU centers. Conclusion: Surprisingly, surgeons in NA and EU centers are faced by different patient populations requiring mechanical heart valve replacement. NA patients were younger, but required more extensive surgery. Surgical technique and perioperative management appear to differ in NA and EU centers. These differences in reporting heart valve procedures might have been influenced by variable interpretations of definitions and different patient expectations, although a uniform study protocol with consistent definitions was used at all sites.
引用
收藏
页码:562 / 571
页数:10
相关论文
共 26 条
  • [1] Differences in heart valve procedures between North American and European centers: A report from the Artificial Valve Endocarditis Reduction Trial (AVERT) - Meeting discussion
    Ghosh, P
    Englberger, L
    Gotlieb, A
    Elkins, R
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (05): : 571 - 571
  • [2] Artificial valve endocarditis reduction trial (AVERT): Protocol of a multicenter randomized trial
    Schaff, H
    Carrel, T
    Steckelberg, JM
    Grunkemeier, GL
    Holubkov, R
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (02): : 131 - 139
  • [3] Prevalence and severity of paravalvular regurgitation in the Artificial Valve Endocarditis Reduction Trial (AVERT) echocardiography study
    Dávila-Román, VG
    Waggoner, AD
    Kennard, ED
    Holubkov, R
    Jamieson, WRE
    Englberger, L
    Carrel, TP
    Schaff, HV
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (07) : 1467 - 1472
  • [4] Importance of implant technique on risk of major paravatvutar teak (PVL) after St. Jude mechanical heart valve replacement: a report from the Artificial Valve Endocarditis Reduction Trial (AVERT)
    Englberger, L
    Schaff, HV
    Jamieson, WRE
    Kennard, ED
    Im, KA
    Holubkov, R
    Carrel, TP
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 28 (06) : 838 - 843
  • [5] Differences between patients with prosthetic valve and native valve endocarditis: Report from the Duke endocarditis service
    Cabell, CH
    Krasuski, RA
    Peterson, GE
    Singh, R
    Woods, CW
    Engemann, JJ
    Fowler, VG
    Chen, AY
    Ryan, T
    Glower, DD
    Wang, A
    CIRCULATION, 2001, 104 (17) : 427 - 427
  • [7] Infective Endocarditis After Transcatheter Pulmonary Valve Replacement Using the Melody Valve: Combined Results of 3 Prospective North American and European Studies
    McElhinney, Doff B.
    Benson, Lee N.
    Eicken, Andreas
    Kreutzer, Jacqueline
    Padera, Robert F.
    Zahn, Evan M.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (03) : 292 - 300
  • [8] Guidelines on prosthetic heart valve management in infective endocarditis: a narrative review comparing American Heart Association/American College of Cardiology and European Society of Cardiology guidelines
    Satriano, Umberto Maria
    Nenna, Antonio
    Spadaccio, Cristiano
    Pollari, Francesco
    Fischlein, Theodor
    Chello, Massimo
    Nappi, Francesco
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (23)
  • [9] Complete heart block resulting from quadricuspid aortic valve penicillin-resistant pneumococcal endocarditis - A case report
    Watanabe, Y
    Taketani, Y
    Takei, Y
    Tanaka, K
    Watanabe, Y
    CIRCULATION JOURNAL, 2003, 67 (03) : 275 - 276
  • [10] Corynebacterium jeikeium native valve infective endocarditis case report: a confirmed microbiological and pathological diagnosis from heart valvular tissue
    Dowling, Wentzel Bruce
    Koen, Johan
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2020, 4 (06)