In-air EIS sensor for in situ and real-time monitoring of in vitro epithelial cells under air-exposure

被引:4
|
作者
Noh, Seungbeom [1 ]
Kim, Hanseup [1 ]
机构
[1] Univ Utah, Dept Elect & Comp Engn, SMBB 3100,50 S Cent Campus Dr, Salt Lake City, UT 84112 USA
关键词
BARRIER FUNCTION; LUNG-CANCER; RESPIRATORY SYMPTOMS; PULMONARY-FUNCTION; POLLUTION; HYPERRESPONSIVENESS; INFLAMMATION; CHILDREN; PARTICLE; MODEL;
D O I
10.1039/c9lc01064e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports in-air monitoring of in vitro monolayer cells under air-exposure utilizing electrochemical impedance spectroscopy (EIS). In-air impedance measurement was performed by placing integrated electrodes laterally, instead of vertically, to a cell membrane, avoiding electrical disconnection, unlike conventional transepithelial-electrical-resistance (TEER). The in-air EIS sensor platform mainly consisted of two chambers, separated by a porous membrane where cells were cultured, that enabled cell exposure to both air (apical side) and liquid (basal side) for long-term measurement. On top of the membrane, EIS interdigitated electrodes were patterned and lung epithelial cells (A549 type II) were cultured with air exposure on one side. The fabricated in-air EIS sensor successfully demonstrated in situ real-time measurement of cell populations in confluency in the range of 7.8 x 10(4) and 9.6 x 10(5) cells per cm(2) at a sensitivity of 3.0 x 10(-2) Omega per cell in impedance and in the range of 1.0 x 10(4) and 9.6 x 10(5) cells per cm(2) at a sensitivity of 0.17 x 10(-15) F per cell in capacitance under AC frequencies of 100 kHz and 1 MHz, respectively. It also successfully monitored transient modulation of tight-junctions that collectively began to open in 30 minutes after the injection of 100 ng ml(-1) TNF-alpha (a relaxation agent), reached maximum relaxation with a 12.6% increase in impedance value and a 12% decrease in capacitance in 60 minutes, and recovered back to its original junction status after 720 minutes, which confirmed the observation in animal models in the literature. Note that the opposite trends in impedance and capacitance allowed the in-air EIS sensor to distinguish cell population changes from tight junction modulation. It was concluded that the developed in-air EIS sensor in an in vitro platform can enable in situ and real-time monitoring of the population of the 'air-exposed' cells as well as the modulation of tight-junctions, which has not been demonstrated yet.
引用
收藏
页码:1751 / 1761
页数:11
相关论文
共 50 条
  • [1] Wireless Sensor Network for Real-Time Air Pollution Monitoring
    Kadri, Abdullah
    Yaacoub, Elias
    Mushtaha, Mohammed
    Abu-Dayya, Adnan
    [J]. 2013 FIRST INTERNATIONAL CONFERENCE ON COMMUNICATIONS SIGNAL PROCESSING, AND THEIR APPLICATIONS (ICCSPA'13), 2013,
  • [2] Real-time optimal spatiotemporal sensor placement for monitoring air pollutants
    Rajib Mukherjee
    Urmila M. Diwekar
    Naresh Kumar
    [J]. Clean Technologies and Environmental Policy, 2020, 22 : 2091 - 2105
  • [3] Real-time optimal spatiotemporal sensor placement for monitoring air pollutants
    Mukherjee, Rajib
    Diwekar, Urmila M.
    Kumar, Naresh
    [J]. CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2020, 22 (10) : 2091 - 2105
  • [4] Real-Time Monitoring of Hazardous Air Pollutants
    Francis, Gregory J.
    Langford, Vaughan S.
    Milligan, Daniel B.
    McEwan, Murray J.
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (04) : 1595 - 1599
  • [5] A Real-Time Integration of Semantic Annotations into Air Quality Monitoring Sensor Data
    Sejdiu, Besmir
    Ismaili, Florije
    Ahmedi, Lule
    [J]. SOFTWARE TECHNOLOGIES (ICSOFT 2020), 2021, 1447 : 98 - 113
  • [6] Real-time Monitoring of Acetaldehyde in Air by Cataluminescence-based Gas Sensor
    Zhou, Kaowen
    Gu, Chunxiu
    Ma, Dongping
    Cao, Hui
    [J]. MATERIALS, MECHANICAL ENGINEERING AND MANUFACTURE, PTS 1-3, 2013, 268-270 : 1594 - 1597
  • [7] A Portable ppb-Level Formaldehyde Sensor for Real-Time Air Quality Monitoring
    Duan, Kun
    Wu, Junjun
    Grabe, Tobias
    Lachmayer, Roland
    Ren, Wei
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 7
  • [8] Real-time Monitoring of Hydrogen Sulfide in Air by Cataluminescence-based Gas Sensor
    Zhou, Kaowen
    Yang, Hongwei
    Li, Xufei
    Yang, Yanying
    [J]. INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 934 - 937
  • [9] Real-Time Monitoring of Air Discharge in a Switchgear by an Intelligent NO2 Sensor Module
    Wang, Qiongyuan
    Li, Haoyuan
    Chu, Jifeng
    Pan, Jianbin
    Yang, Aijun
    Xiao, Song
    Yuan, Huan
    Rong, Mingzhe
    Wang, Xiaohua
    [J]. ACS SENSORS, 2023, 8 (12) : 4646 - 4654
  • [10] Denuder based real-time air monitoring methods
    Jenkins, Amanda L.
    Buettner, Leonard C.
    Ellzy, Michael W.
    Bruni, Eric J.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245