Optimization of reverse osmosis treatment process to reuse the distillery wastewater using Taguchi design

被引:14
|
作者
Thirugnanasambandham, K. [1 ]
Sivakumar, V. [2 ]
Shine, K. [3 ]
机构
[1] Excel Coll Engn & Technol, Dept Chem, Namakkal 637303, TN, India
[2] Anna Univ, Dept Chem Engn, AC Tech Campus, Madras 60005, Tamil Nadu, India
[3] King Saud Univ, Dept Bot & Microbiol, Coll Sci, Post Box 2455, Riyadh 11451, Saudi Arabia
关键词
Distillery wastewater; Reverse osmosis; Optimization; Taguchi design; Validation; RO MEMBRANES;
D O I
10.1080/19443994.2016.1141323
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, the reverse osmosis (RO) treatment of distillery wastewater was studied using various operating conditions including pH, temperature, transmembrane pressure, and feed flow rate. Taguchi method was used to design the experiments and optimize the RO treatment process for the maximum permeate flux and removal of salinity and COD. L-9 (3(4)) orthogonal array for experimental design and the larger-the-better response category was applied to find optimum parameters. The optimum conditions were found to be as pH (6), temperature (45 degrees C), transmembrane pressure (10bar), and flow rate (300l/h). Under these conditions, 80l/hm(2) permeate flux was achieved with 91% of salinity removal and 85% of COD removal. The obtained results revealed that RO treatment technique was an effective treatment technology for the reuse of distilleries wastewater.
引用
收藏
页码:24222 / 24230
页数:9
相关论文
共 50 条