The behavior of a poly(aniline) solid contact pH selective electrode based on N,N,N′,N′-tetrabenzylethanediamine ionophore

被引:13
|
作者
Han, WS
Park, MY
Cho, DH
Hong, TK
Lee, DH
Park, JM
Chung, KC [1 ]
机构
[1] Konkuk Univ, Dept Chem, Seoul 143701, South Korea
[2] Hanseo Univ, Dept Chem, Chungnam 356820, South Korea
关键词
D O I
10.2116/analsci.17.727
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hydrogen ion-selective solid-contact electrode based on N,N,N',N'-tetrabenzylethanediamine has shown the best Nernstian slope and selectivity and the widest response range in a Tris buffered pH sample solution. Its linear dynamic range was pH 3.50 - 11.94, and the Nernstian slope showed 52.1 mV/pH (at 20 +/- 0.2 degreesC). When it was directly applied to human whole blood tin pH range 6.0 - 8.5) we could obtain the same satisfying results. This electrode continuously contacted a Tris 7.47 buffered solution, human whole blood and a hydrofluoric acid solution for one month without any loss of performance. Also, hydrofluoric acid did not influence the surface of this electrode, and thus it was maintained without showing any changes in potentials after being used in a hydrofluoric acid solution. The standard deviation in the determined e.m.f. differences was 1.5 mV (N = 5) for Tris buffer solutions of pH 6.5 and 1.1 mV at a Tris buffer solutions of pH 8.5. The 90% response time of the electrodes obtained by injecting of hydrochloric acid into the Tris buffer sample solution was less than 10 s. Especially, in the this paper, with these potential response characteristics of hydrogen ion selective poly(aniline) solid contact electrode, we have also presented the pH response mechanism of this electrode and the role of poly(aniline) and a doped anion in a poly(aniline) layer.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 50 条
  • [1] The Behavior of a Poly(aniline) Solid Contact pH Selective Electrode Based on N,N,N′,N′-Tetrabenzylethanediamine Ionophore
    Won-Sik Han
    Myon-Yong Park
    Dong-Hoe Cho
    Tae-Kee Hong
    Dong-Hoon Lee
    Jong-Man Park
    Koo-Chun Chung
    Analytical Sciences, 2001, 17 : 727 - 732
  • [2] Conventional and solid-contact lithium-selective electrodes based on tris[(N,N-dicyclohexylamide) neutral ionophore
    Grekovich, AL
    Markuzina, NN
    Mikhelson, KN
    Bochenska, M
    Lewenstam, A
    ELECTROANALYSIS, 2002, 14 (7-8) : 551 - 555
  • [3] Mercury ion selective poly(aniline) solid contact electrode based on 2-mercaptobenzimidazol ionophore
    Won-Sik Han
    Koang-Chul Wi
    Woon-Suk Park
    Tae-Kee Hong
    Russian Journal of Electrochemistry, 2012, 48 : 525 - 531
  • [4] Mercury ion selective poly(aniline) solid contact electrode based on 2-mercaptobenzimidazol ionophore
    Han, Won Sik
    Wi, Koang Chul
    Park, Woon Suk
    Hong, Tae Kee
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2012, 48 (05) : 525 - 531
  • [5] Cyanide ion selective solid contact electrode based on nickel complex of N,N′-bis-(4-phenylazosalicylidene)-o-phenylene diamine ionophore
    Won-Sik Han
    Hak-Joo Lee
    Jung-Sub Lee
    Young-Hoon Lee
    Tae-Kee Hong
    Journal of Analytical Chemistry, 2014, 69 : 187 - 193
  • [6] Cyanide ion selective solid contact electrode based on nickel complex of N,N′-bis-(4-phenylazosalicylidene)-o-phenylene diamine ionophore
    Han, Won-Sik
    Lee, Hak-Joo
    Lee, Jung-Sub
    Lee, Young-Hoon
    Hong, Tae-Kee
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (02) : 187 - 193
  • [7] Lead(II) ion selective poly(aniline) solid contact electrode based on 1,2-bis(N′-benzoylthioureido)ethane, -propane and -butane ionophores
    Young-Hoon Lee
    Won-Sik Han
    Hak-Joo Lee
    Sung-Min Ahn
    Tae-Kee Hong
    Journal of Analytical Chemistry, 2015, 70 : 621 - 626
  • [8] Lead(II) ion selective poly(aniline) solid contact electrode based on 1,2-bis(N'-benzoylthioureido)ethane, -propane and -butane ionophores
    Lee, Young-Hoon
    Han, Won-Sik
    Lee, Hak-Joo
    Ahn, Sung-Min
    Hong, Tae-Kee
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) : 621 - 626
  • [9] A Hydrogen Ion-Selective Poly(aniline) Solid Contact Electrode Based on Dibenzylpyrenemethylamine Ionophore for Highly Acidic Solutions
    Won-Sik Han
    Koo-Chun Chung
    Myung-Hoon Kim
    Hyun-Baek Ko
    Young-Hoon Lee
    Tae-Kee Hong
    Analytical Sciences, 2004, 20 : 1419 - 1422
  • [10] A hydrogen ion-selective poly(aniline) solid contact electrode based on dibenzylpyrenemethylamine ionophore for highly acidic solutions
    Han, WS
    Chung, KC
    Kim, MH
    Ko, HB
    Lee, YH
    Hong, TK
    ANALYTICAL SCIENCES, 2004, 20 (10) : 1419 - 1422