Evaluation of Muscle Synergy During Exoskeleton-Assisted Walking in Persons With Multiple Sclerosis

被引:10
|
作者
Afzal, Taimoor [1 ,2 ]
Zhu, Fangshi [1 ,3 ]
Tseng, Shih-Chiao [4 ]
Lincoln, John A. [5 ]
Francisco, Gerard E. [1 ,3 ]
Su, Hao [6 ]
Chang, Shuo-Hsiu [1 ,3 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, Dept Phys Med & Rehabil, Houston, TX 77030 USA
[2] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
[3] Neurorecovery Res Ctr TIRR Mem Hermann, Ctr Wearable Exoskeletons, Houston, TX USA
[4] Univ Texas Med Branch, Dept Phys Therapy, Galveston, TX 77555 USA
[5] Univ Texas Hlth Sci Ctr Houston, Dept Neurol, Houston, TX 77030 USA
[6] North Carolina State Univ, Dept Mech & Aerosp Engn, Lab Biomechatron & Intelligent Robot, Raleigh, NC USA
关键词
Muscles; Legged locomotion; Exoskeletons; Multiple sclerosis; Training; Turning; Knee; multiple sclerosis; gait; muscle synergy; GAIT; VARIABILITY; IMPAIRMENT; DISABILITY; COMPLEXITY;
D O I
10.1109/TBME.2022.3166705
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Gait deficit after multiple sclerosis (MS) can be characterized by altered muscle activation patterns. There is preliminary evidence of improved walking with a lower limb exoskeleton in persons with MS. However, the effects of exoskeleton-assisted walking on neuromuscular modifications are relatively unclear. The objective of this study was to investigate the muscle synergies, their activation patterns and the differences in neural strategies during walking with (EXO) and without (No-EXO) an exoskeleton. Methods: Ten subjects with MS performed walking during EXO and No-EXO conditions. Electromyography signals from seven leg muscles were recorded. Muscle synergies and the activation profiles were extracted using non-negative matrix factorization. Results: The stance phase duration was significantly shorter during EXO compared to the No-EXO condition (p<0.05). Moreover, typically 3-5 modules were extracted in each condition. The module-1 (comprising Vastus Medialis and Rectus Femoris muscles), module-2 (comprising Soleus and Medial Gastrocnemius muscles), module-3 (Tibialis Anterior muscle) and module-4 (comprising Biceps Femoris and Semitendinosus muscles) were comparable between conditions. During EXO condition, Semitendinosus and Vastus Medialis emerged in module-5 in 7/10 subjects. Compared to No-EXO, average activation amplitude was significantly reduced corresponding to module-2 during the stance phase and module-3 during the swing phase during EXO. Conclusion: Exoskeleton-assistance does not alter the existing synergy modules, but could induce a new module to emerge, and alters the control of these modules, i.e., modifies the neural commands indicated by the reduced amplitude of the activation profiles. Significance: The work provides insights on the potential underlying mechanism of improving gait functions after exoskeleton-assisted locomotor training.
引用
收藏
页码:3265 / 3274
页数:10
相关论文
共 50 条
  • [1] Cognitive Demands during Wearable Exoskeleton Assisted Walking in Persons with Multiple Sclerosis
    Afzal, Taimoor
    Kern, Marcie
    Tseng, Shih-Chiao
    Lincoln, John
    Francisco, Gerard
    Chang, Shuo-Hsiu
    2017 INTERNATIONAL SYMPOSIUM ON WEARABLE ROBOTICS AND REHABILITATION (WEROB), 2017, : 76 - 77
  • [3] Biomechanics of Exoskeleton-Assisted Treadmill Walking
    Di Tommaso, F.
    Tamburella, F.
    Lorusso, M.
    Gastaldi, L.
    Molinari, M.
    Tagliamonte, N. L.
    2023 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, ICORR, 2023,
  • [4] Exoskeleton-assisted Gait Training in Persons With Multiple Sclerosis: A Single-Group Pilot Study
    Afzal, Taimoor
    Tseng, Shih-Chiao
    Lincoln, John A.
    Kern, Marcie
    Francisco, Gerard E.
    Chang, Shuo-Hsiu
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2020, 101 (04): : 599 - 606
  • [5] Heart rate and oxygen demand of powered exoskeleton-assisted walking in persons with paraplegia
    Asselin, Pierre
    Knezevic, Steven
    Kornfeld, Stephen
    Cirnigliaro, Christopher
    Agranova-Breyter, Irina
    Bauman, William A.
    Spungen, Ann M.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2015, 52 (02): : 147 - 158
  • [6] Cardiorespiratory and Metabolic Responses During Robotic Exoskeleton-Assisted Walking Among Persons with Chronic Spinal Cord Injury
    Evans, Nicholas
    Hartigan, Clare
    Kandilakis, Casey
    Clesson, Ismari
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 632 - 632
  • [7] Safety of Exoskeleton-Assisted Walking in SCI Inpatient Rehabilitation
    Delgado, Andrew D.
    Escalon, Miguel X.
    Kozlowski, Allan J.
    Weinrauch, William
    Suarez, Stephanie J.
    Bryce, Thomas N.
    Wecht, Jill M.
    Tsai, Chung-Ying
    Spungen, Ann M.
    2017 INTERNATIONAL SYMPOSIUM ON WEARABLE ROBOTICS AND REHABILITATION (WEROB), 2017, : 26 - 27
  • [8] EXOSKELETON-ASSISTED WALKING IN PATIENTS WITH SPINAL CORD INJURY: PSYCHOLOGICAL, SOMATIC AND VISCERAL EVALUATION
    di Vico, Tommaso
    Durante, Jacopo
    Bracchitta, Damiano
    Stampacchia, Giulia
    Gerini, Adriana
    Pistolesi, Donatella
    NEUROUROLOGY AND URODYNAMICS, 2017, 36 : S34 - S35
  • [9] A pilot randomized controlled trial of robotic exoskeleton-assisted exercise rehabilitation in multiple sclerosis
    Androwis, Ghaith J.
    Sandroff, Brian M.
    Niewrzol, Peter
    Fakhoury, Farris
    Wylie, Glenn R.
    Yue, Guang
    DeLuca, John
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2021, 51
  • [10] Exoskeleton-Assisted Walking for Pulmonary and Exercise Performances of SCI Individuals
    Xiang, Xiao-Na
    Zhang, Li-Ming
    Zong, Hui-Yan
    Ou, Yi
    Yu, Xi
    Liu, Yan
    Jiang, Hong-Ying
    Cheng, Hong
    He, Hong-Chen
    He, Cheng-Qi
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 39 - 47