A NEW SYMMETRY-BASED METHOD FOR MID-SAGITTAL PLANE EXTRACTION IN NEUROIMAGES

被引:0
|
作者
Ruppert, Guilherme C. S. [1 ,2 ]
Teverovskiy, Leonid [3 ]
Yu, Chen-Ping [4 ]
Falcao, Alexandre X. [1 ]
Liu, Yanxi [3 ,4 ]
机构
[1] Univ Estadual Campinas, Inst Comp, Av Albert Einstein 1251, Campinas, SP, Brazil
[2] Ctr Informat Technol Renato Archer, Campinas, SP, Brazil
[3] Carnegie Mellon Univ, Robot Inst, Pittsburgh, PA USA
[4] Penn State Univ, Comp Sci & Engn, University Pk, PA 16802 USA
基金
巴西圣保罗研究基金会;
关键词
mid-sagittal plane extraction; symmetry quantification; neuroimage registration; medical image analysis; MIDSAGITTAL PLANE; ROBUST;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The estimation of the mid-sagittal plane (MSP) is a known problem with several applications in neuroimage analysis. As advance to the state-of-the-art, we present a considerably better approach for MSP extraction based on bilateral symmetry maximization and a more suitable error metric to compare MSP estimation methods. The proposed method was quantitatively evaluated using three other state-of-the-art approaches as baselines and a heterogeneous dataset with 164 clinical images. It outperformed the others in accuracy and precision, being well succeeded on all images. Besides, it does not present limitations with respect to the imaging protocol and initial position of the head, and it is one of the fastest methods in the literature, taking around 30 seconds on a regular workstation.
引用
收藏
页码:285 / 288
页数:4
相关论文
共 50 条
  • [1] Mid-sagittal plane and mid-sagittal surface optimization in brain MRI using a local symmetry measure
    Stegmann, MB
    Skoglund, K
    Ryberg, C
    [J]. MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 568 - 579
  • [2] Automatic extraction of the mid-sagittal plane using an ICP variant
    Fieten, Lorenz
    Eschweiler, Joerg
    de la Fuente, Matias
    Gravius, Sascha
    Radermacher, Klaus
    [J]. MEDICAL IMAGING 2008: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, PTS 1 AND 2, 2008, 6918
  • [3] Symmetry Recognition using Mid-Sagittal Plane Extraction and Tilt Correction in 3D Head Images
    Zhang, Rui
    Sato, Takako
    Arisawa, Hiroshi
    [J]. 2013 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2013, : 761 - 766
  • [4] Brain mid-sagittal surface extraction based on fractal analysis
    Seyed Hashem Davarpanah
    Alan Wee-Chung Liew
    [J]. Neural Computing and Applications, 2018, 30 : 153 - 162
  • [5] Brain mid-sagittal surface extraction based on fractal analysis
    Davarpanah, Seyed Hashem
    Liew, Alan Wee-Chung
    [J]. NEURAL COMPUTING & APPLICATIONS, 2018, 30 (01): : 153 - 162
  • [6] Reemerging stress:: Supraorbital torus morphology in the mid-sagittal plane?
    Prossinger, H
    Bookstein, F
    Schäfer, K
    Seidler, H
    [J]. ANATOMICAL RECORD, 2000, 261 (05): : 170 - 172
  • [7] Automated detection of mid-sagittal plane in MR images of the head
    Wang, DM
    Chalk, JB
    Doddrell, DM
    Semple, J
    [J]. MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1243 - 1253
  • [8] Automatic extraction of brain surface and mid-sagittal plane from PET images applying deformable models
    Mykkänen, J
    Tohka, J
    Luoma, J
    Ruotsalainen, U
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2005, 79 (01) : 1 - 17
  • [9] Computation of the mid-sagittal plane in 3-D brain images
    Prima, S
    Ourselin, S
    Ayache, N
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) : 122 - 138
  • [10] Mid-sagittal plane detection in brain magnetic resonance image based on multifractal techniques
    Ramasamy, Uthayakumar
    Arulprakash, Gowrisankar
    [J]. IET IMAGE PROCESSING, 2016, 10 (10) : 751 - 762