Advanced Photonic Sensors Based on Interband Cascade Lasers for Real-Time Mouse Breath Analysis

被引:25
|
作者
Tuetuencue, Erhan [1 ]
Nagele, Maerkus [2 ]
Becker, Steffen [3 ]
Fischer, Marc [3 ]
Koeth, Johannes [3 ]
Wolf, Christian [4 ]
Kostler, Stefan [4 ]
Ribitsch, Volker [5 ]
Teuber, Andrea [1 ]
Groeger, Michael [6 ]
Kress, Sandra [6 ]
Wepler, Martin [6 ]
Wachter, Ulrich [6 ]
Vogt, Josef [6 ]
Radermacher, Peter [6 ]
Mizaikoff, Boris [1 ]
机构
[1] Ulm Univ, Inst Analyt & Bioanalyt Chem, Albert Einstein Allee 11, D-89081 Ulm, Germany
[2] OptoPrecision GmbH, Hohe 15, D-28357 Bremen, Germany
[3] Nanoplus Nanosyst & Technol GmbH, Oberer Kirschberg 4, D-97218 Gerbrunn, Germany
[4] Joanneum Res Forsch Gesell MbH, Mat Inst Oberflachentechnol & Photon, Franz Pichler Str 30, A-8160 Weiz, Austria
[5] TecSense GmbH, Teslastr 4, A-8074 Grambach, Austria
[6] Ulm Univ, Med Ctr, Inst Anesthesiol Pathophysiol & Method Dev, Helmholtzstr 8-1, D-89081 Ulm, Germany
来源
ACS SENSORS | 2018年 / 3卷 / 09期
基金
欧盟地平线“2020”;
关键词
substrate integrated hollow waveguides; breath analysis; interband cascade laser; electrospun polymer nanofiber; isotope enrichment; SPECTROSCOPY;
D O I
10.1021/acssensors.8b00477
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A multiparameter gas sensor based on distributed feedback interband cascade lasers emitting at 4.35 mu m and ultrafast electro-spun luminescence oxygen sensors has been developed for the quantification and continuous monitoring of (CO2)-C-13/(CO2)-C-12 isotopic ratio changes and oxygen in exhaled mouse breath samples. Mid-infrared absorption spectra for quantitatively monitoring the enrichment of (CO2)-C-13 levels were recorded in a miniaturized dual-channel substrate-integrated hollow waveguide using balanced ratiometric detection, whereas luminescence quenching was used for synchronously detecting exhaled oxygen levels. Allan variance analysis verified a CO2 measurement precision of 1.6 parts per thousand during a 480 s integration time. Routine online monitoring of exhaled mouse breath was performed in 14 mechanically ventilated and instrumented mice and demonstrated the feasibility of online isotope-selective exhaled breath analysis within microliters of probed gas samples using the reported combined sensor platform.
引用
收藏
页码:1743 / 1749
页数:13
相关论文
共 50 条
  • [1] Current status of midinfrared quantum and interband cascade lasers for clinical breath analysis
    Risby, Terence H.
    Tittel, Frank K.
    OPTICAL ENGINEERING, 2010, 49 (11)
  • [2] Sensitive, Real-Time Interband Cascade Laser Based Sensor for Ethane Monitoring
    Bakhikrin, Yury A.
    Wysocki, Gerard
    Fraser, Matthew P.
    Yang, Rui Q.
    Tittel, Frank K.
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 1599 - +
  • [3] Drug Pharmacokinetics Determined by Real-Time Analysis of Mouse Breath
    Li, Xue
    Sinues, Pablo Martinez-Lozano
    Dallmann, Robert
    Bregy, Lukas
    Hollmen, Maija
    Proulx, Steven
    Brown, Steven A.
    Detmar, Michael
    Kohler, Malcolm
    Zenobi, Renato
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2015, 54 (27) : 7815 - 7818
  • [4] Compact Real-Time Terahertz Spectroscopy Based on Quantum Cascade Lasers
    Li, Hua
    Li, Ziping
    Wan, Wenjian
    Zhou, Kang
    Cao, J. C.
    2019 44TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2019,
  • [5] Photoacoustic trace-analysis of breath isoprene and acetone via interband-and Quantum Cascade Lasers
    Pangerl, Jonas
    Sukul, Pritam
    Rueck, Thomas
    Escher, Lukas
    Miekisch, Wolfram
    Bierl, Rudolf
    Matysik, Frank-Michael
    SENSORS AND ACTUATORS B-CHEMICAL, 2025, 424
  • [6] Terahertz quantum cascade lasers and real-time THz imaging
    Hu, Qing
    2007 IEEE LEOS ANNUAL MEETING CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 2007, : 858 - 859
  • [7] Real-Time Power Analysis of Smart Sensors Using Advanced Debugging Methods
    Gis, Daniel
    Buscher, Nils
    Haubelt, Christian
    MICROMACHINES, 2021, 12 (11)
  • [8] Real-time breath analysis towards a healthy human breath profile
    Sasiene, Zachary Joseph
    LeBrun, Erick Scott
    Schaller, Eric
    Mach, Phillip Michael
    Taylor, Robert
    Candelaria, Lionel
    Glaros, Trevor Griffiths
    Baca, Justin
    McBride, Ethan Matthew
    JOURNAL OF BREATH RESEARCH, 2024, 18 (02)
  • [9] Off-axis integrated cavity output spectroscopy with a mid-infrared interband cascade laser for real-time breath ethane measurements
    Parameswaran, Krishnan R.
    Rosen, David I.
    Allen, Mark G.
    Ganz, Alan M.
    Risby, Terence H.
    APPLIED OPTICS, 2009, 48 (04) : B73 - B79
  • [10] Microoptoelectromechanical systems-based external cavity quantum cascade lasers for real-time spectroscopy
    Butschek, Lorenz
    Hugger, Stefan
    Jarvis, Jan
    Haertelt, Marko
    Merten, Andre
    Schwarzenberg, Markus
    Grahmann, Jan
    Stothard, David
    Warden, Matthew
    Carson, Christopher
    Macarthur, John
    Fuchs, Frank
    Ostendorf, Ralf
    Wagner, Joachim
    OPTICAL ENGINEERING, 2018, 57 (01)