Stress and adhesion in DLC coatings on 316L stainless steel deposited by a neutral beam source

被引:31
|
作者
Morshed, MM [1 ]
McNamara, BP [1 ]
Cameron, DC [1 ]
Hashmi, MSJ [1 ]
机构
[1] Dublin City Univ, Natl Ctr Plasma Sci & Technol, Dublin 9, Ireland
关键词
DLC; adhesion; stress; neutral beam; implant;
D O I
10.1016/S0924-0136(03)00246-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Diamond-like carbon (DLC) films have been deposited on medical implant grade 316L stainless steel substrates using a saddle field source neutral beam deposition system. The deposition characteristics have been determined as a function of system parameters and it has been shown that the deposition rate is largely independent of chamber pressure. The film structure has been investigated using Raman spectroscopy and from the peak positions and intensities the sp(3) content has been estimated to be similar to20% maximum. No significant change with film pressure has been observed but higher anode currents may lead to higher sp(3) content. The adhesion strength has been found to be inversely proportional to the residual stress and to increase at lower deposition pressures. At a source anode current of 0.6 A the adhesion is a monotonic function of pressure in the range examined whereas with 1.0 A source current the behaviour is more complex. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:127 / 131
页数:5
相关论文
共 50 条
  • [1] Stress and adhesion in DLC coatings on 316L stainless steel deposited by a neutral beam source
    Morshed, MM
    McNamara, BP
    Cameron, DC
    Hashmi, MSJ
    [J]. JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2003, 143 : 922 - 926
  • [2] Effect of surface treatment on the adhesion of DLC film on 316L stainless steel
    Morshed, MM
    McNamara, BP
    Cameron, DC
    Hashmi, MSJ
    [J]. SURFACE & COATINGS TECHNOLOGY, 2003, 163 : 541 - 545
  • [3] Preparation and characterisation of electrophoretically deposited hydroxyapatite coatings on type 316L stainless steel
    Sridhar, TM
    Mudali, UK
    Subbaiyan, M
    [J]. CORROSION SCIENCE, 2003, 45 (02) : 237 - 252
  • [4] PECVD of biocompatible coatings on 316L stainless steel
    Prasad, GR
    Daniels, S
    Cameron, DC
    McNamara, BP
    Tully, E
    O'Kennedy, R
    [J]. SURFACE & COATINGS TECHNOLOGY, 2005, 200 (1-4): : 1031 - 1035
  • [5] On the adhesion of diamond-like carbon coatings deposited by low-pressure plasma on 316L stainless steel
    Morand, Gabriel
    Chevallier, Pascale
    Bonilla-Gameros, Linda
    Turgeon, Stephane
    Cloutier, Maxime
    Da Silva Pires, Mathieu
    Sarkissian, Andranik
    Tatoulian, Michael
    Houssiau, Laurent
    Mantovani, Diego
    [J]. SURFACE AND INTERFACE ANALYSIS, 2021, 53 (07) : 658 - 671
  • [6] Tribocorrosion behaviour of DLC-coated 316L stainless steel
    Azzi, M.
    Paquette, M.
    Szpunar, J. A.
    Klemberg-Sapieha, J. E.
    Martinu, L.
    [J]. WEAR, 2009, 267 (5-8) : 860 - 866
  • [7] Investigation of laser direct deposited 316L stainless steel
    Zhang Yongzhong
    Gao Shiyou
    Xi Mingzhe
    Shi Likai
    [J]. JOURNAL OF ADVANCED MATERIALS, 2007, 39 (04): : 34 - 38
  • [8] Characterization of ZrC coatings deposited on biomedical 316L stainless steel by magnetron sputtering method
    Ding Ming-hui
    Zhang Hong-sen
    Zhang Chi
    Jin Xing
    [J]. SURFACE & COATINGS TECHNOLOGY, 2013, 224 : 34 - 41
  • [9] Plasma polymerized allylamine films deposited on 316L stainless steel for cardiovascular stent coatings
    Gallino, Enrico
    Massey, Sylvain
    Tatoulian, Michael
    Mantovani, Diego
    [J]. SURFACE & COATINGS TECHNOLOGY, 2010, 205 (07): : 2461 - 2468
  • [10] On the wear of TiBx/TiSiyCz coatings deposited on 316L steel
    Twardowska, Agnieszka
    Morgiel, Jerzy
    Rajchel, Boguslaw
    [J]. INTERNATIONAL JOURNAL OF MATERIALS RESEARCH, 2015, 106 (07) : 758 - 763