Flame temperature diagnostics with water lines usingmid-infrared degenerate four-wave mixing

被引:18
|
作者
Sun, Z. W. [1 ]
Li, Z. S. [1 ]
Li, B. [1 ]
Alden, M. [1 ]
机构
[1] Lund Univ, Div Combust Phys, S-22100 Lund, Sweden
基金
欧洲研究理事会; 瑞典研究理事会;
关键词
degenerate four-wave mixing; mid-infrared spectroscopy; temperature diagnostics; water IR spectroscopy; MIDINFRARED POLARIZATION SPECTROSCOPY; LASER-INDUCED FLUORESCENCE; TUNABLE DIODE-LASER; ATOMIC FLUORESCENCE; PRESSURE FLAMES; OH; GASES; THERMOMETRY; SENSOR; CO2;
D O I
10.1002/jrs.2894
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The feasibility of using degenerate four-wave mixing (DFWM) for hot gas thermometry in the mid-infrared spectral region is, for the first time, demonstrated by probing molecular ro-vibrational transitions of water. DFWM spectra of hot water were recorded in specially designed flames, providing a series of temperatures varying from 1000 to 1900 K and, the dramatic spectral structure variations were used as temperature indicator. The intensity ratios between two hot water line groups at around 3231 cm(-1) were especially studied and composed into a calibration table for flame temperature measurement using DFWM spectra. The saturation properties of different lines were also studied by recording the line intensity ratios as a function of laser power, and the results indicated that saturated excitation was in favor of reliable temperature measurements. As validation, infrared DFWM spectra in phi = 1.52 flat premixed methane/air flame were recorded, and a good temperature value was obtained. Moreover, the recently released HITEMP2010 database as well as its previous version HITEMP2000 were adopted to simulate the hot water spectra and to analyze the line intensity ratios. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:1828 / 1835
页数:8
相关论文
共 50 条
  • [1] Broadband degenerate four-wave mixing of OH for flame thermometry
    G.M. Lloyd
    I.G. Hughes
    R. Bratfalean
    P. Ewart
    Applied Physics B, 1998, 67 : 107 - 113
  • [2] Broadband degenerate four-wave mixing of OH for flame thermometry
    Lloyd, GM
    Hughes, IG
    Bratfalean, R
    Ewart, P
    APPLIED PHYSICS B-LASERS AND OPTICS, 1998, 67 (01): : 107 - 113
  • [3] Combustion flame diagnostics using degenerate four-wave mixing: the dipole moment power law and rotational temperature for nitric oxide
    Flieser, J
    Iskra, K
    Morozov, A
    Pichler, G
    Neger, T
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (04) : 402 - 409
  • [4] Angular dependence of OH degenerate four-wave mixing signals in a flame
    Lai, MC
    Li, L
    Xie, XB
    OPTICS AND LASERS IN ENGINEERING, 1997, 28 (03) : 229 - 235
  • [5] Excited degenerate four-wave mixing
    Wuli Xuebao, 2 (210-213):
  • [6] Quality in upconversion imaging of infrared degenerate four-wave mixing spectroscopy
    Morishita, K
    Kawaguchi, N
    Okada, T
    OPTICS COMMUNICATIONS, 2000, 184 (5-6) : 443 - 450
  • [7] Room temperature degenerate four-wave mixing in CuCl thin films
    Ichimiya, Masayoshi
    Mochizuki, Keita
    Ashida, Masaaki
    Yasuda, Hideki
    Ishihara, Hajime
    Itoh, Tadashi
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2011, 248 (02): : 456 - 459
  • [8] Degenerate four-wave mixing in noncentrosymmetric materials
    Biaggio, Ivan
    Physical Review A. Atomic, Molecular, and Optical Physics, 2001, 64 (06): : 1 - 063813
  • [9] Degenerate four-wave mixing in noncentrosymmetric materials
    Biaggio, I
    PHYSICAL REVIEW A, 2001, 64 (06): : 13
  • [10] Degenerate four-wave mixing in atomic ytterbium
    Li, Tian
    Baker, Ryan P.
    Weinstein, Jonathan D.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2012, 29 (10) : 2848 - 2851