Fractionation effects in particle radiotherapy: implications for hypo-fractionation regimes

被引:37
|
作者
Carabe-Fernandez, A. [1 ]
Dale, R. G. [2 ]
Hopewell, J. W. [3 ]
Jones, B. [3 ]
Paganetti, H. [1 ]
机构
[1] Harvard Univ, Sch Med, Dept Radiat Oncol, Francis H Burr Proton Therapy Ctr,Massachusetts G, Boston, MA 02114 USA
[2] Charing Cross Hosp, Dept Radiat Phys & Radiobiol, Imperial Coll Healthcare NHS Trust, London W6 8RF, England
[3] Univ Oxford, Particle Therapy Canc Res Inst, Oxford OX1 3RH, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 19期
关键词
RELATIVE BIOLOGICAL EFFECTIVENESS; LINEAR-QUADRATIC MODEL; NEUTRONS 42 MEVD->BE; CARBON-ION RADIOTHERAPY; X-RAYS; NORMAL-TISSUES; MAMMALIAN-CELLS; HEAVY-IONS; PIG; IRRADIATION;
D O I
10.1088/0031-9155/55/19/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim is to demonstrate the potential impact of changes in the value of the beta parameter in the linear quadratic (LQ) model on the calculation of clinical relative biological effectiveness (RBE) values used for high linear energy transfer (LET) radiotherapy. The parameter RBE(min) is introduced into the LQ formulation to account for possible changes in the beta radiosensitivity coefficient with changing LET. The model is used to fit fractionated data under two conditions, where RBE(min) = 1 and RBE(min) not equal 1. Nonlinear regression and analysis of variance are used to test the hypothesis that the inclusion of a non-unity value of RBE(min) better predicts the total iso-effective dose required at low number of fractions for fast neutrons, carbon ions, pi-meson and proton fractionation data obtained for various tissues from previous publications. For neutrons the assumption of RBE(min) not equal 1 provided a better fit in 89% of the cases, whereas for carbon ions RBE(min) not equal 1 provided a better fit only for normal tissue at the spread-out Bragg peak. The results provide evidence of the impact that variations in the beta parameter may have when calculating clinically relevant RBE values, especially when using high doses per fraction (i.e. hypofractionation) of high-LET radiations.
引用
收藏
页码:5685 / 5700
页数:16
相关论文
共 50 条
  • [1] HYPO-FRACTIONATION - RESPONSE
    HUILGOL, NG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1989, 16 (06): : 1655 - 1655
  • [2] Model-Supported Radiotherapy Personalization: In silico Test of Hyper- and Hypo-Fractionation Effects
    Belfatto, Antonella
    Jereczek-Fossa, Barbara Alicja
    Baroni, Guido
    Cerveri, Pietro
    FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [3] Comparison of Linear Quadratic (L-Q) Models for Hypo-Fractionation Radiotherapy
    Yue, C.
    Zhu, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E347 - E347
  • [4] Postoperative Radiotherapy of Prostate Cancer - Conventional versus Hypo-Fractionation: Analysis of Side Effects in 691 Patients
    Goldner, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (11) : 1076 - 1077
  • [5] Fractionated grid therapy in treating cervical cancers: Hypo-Fractionation or conventional fractionation?
    Zhang, H.
    Wang, J.
    Mayr, N.
    Kong, X.
    Yuan, J.
    Gupta, N.
    Lo, S.
    Grecular, J.
    Montebello, J.
    Martin, D.
    Yuh, W.
    MEDICAL PHYSICS, 2007, 34 (06) : 2567 - 2567
  • [6] Spatiotemporal Dose Shaping to Achieve Uniform Fractionation in Healthy Tissues Along with Hypo-Fractionation in Targets
    Unkelbach, J.
    Bussiere, M.
    Shih, H.
    Chapman, P.
    Loeffler, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3741 - 3742
  • [7] Re-Irradiation with Extreme Hypo-Fractionation to the Prostate for Local Recurrence after Primary Radiotherapy
    Lewin, R.
    Laufer, M.
    Berger, R.
    Tsvang, L.
    ben-Ayun, M.
    Weiss, I.
    Symon, Z.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E882 - E883
  • [8] Change in prostate volume during extreme hypo-fractionation analysed with MRI
    Gunnlaugsson, A.
    Kjellen, E.
    Hagberg, O.
    Thellenberg-Karlsson, C.
    Widmark, A.
    Nilsson, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S33 - S33
  • [9] Change in prostate volume during extreme hypo-fractionation analysed with MRI
    Gunnlaugsson, Adalsteinn
    Kjellen, Elisabeth
    Hagberg, Oskar
    Thellenberg-Karlsson, Camilla
    Widmark, Anders
    Nilsson, Per
    RADIATION ONCOLOGY, 2014, 9
  • [10] Change in prostate volume during extreme hypo-fractionation analysed with MRI
    Adalsteinn Gunnlaugsson
    Elisabeth Kjellén
    Oskar Hagberg
    Camilla Thellenberg-Karlsson
    Anders Widmark
    Per Nilsson
    Radiation Oncology, 9