Cryogenic system design for HTS power transmission cable cooling with sub-cooled liquid nitrogen

被引:0
|
作者
Fan, YF [1 ]
Zhang, L [1 ]
Gong, LH [1 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100080, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The cryogenic system that is being built will be supplied to the Institute of Electrical Engineering (IEE), CAS, for the cooling of the 3-phase HTS transmission cable. It consists of a centrifugal cryogenic pump, a vacuum pump, a sub-cooler, and a pressurization tank. The cryogenic system can continuously run in the temperature range of 66 K to 76 K because there are two 300L liquid nitrogen (LN2) storage tanks that alternate in use to supply LN2 to the sub-cooler and will yield the continuous cooling power. The design cooling power of the cryogenic system is 3 KW while the liquid nitrogen (@ 77 K, 0.1 MPa) consumed will be less than 80 liter per hour and the working pressures can also be regularly adjusted within the range between 0.1 MPa and I MPa. The Monitor and Control Generated System (MCGS) program is used to acquire the data and control the system to the demand state. The design, construction, cooling power and control system of the cryogenic system will be reported in this paper.
引用
收藏
页码:277 / 280
页数:4
相关论文
共 50 条
  • [1] Cryogenic system with the sub-cooled liquid nitrogen for cooling HTS power cable
    Fan, YF
    Gong, LH
    Xu, XD
    Li, LF
    Zhang, L
    Xiao, LY
    [J]. CRYOGENICS, 2005, 45 (04) : 272 - 276
  • [2] Sub-cooled Liquid Nitrogen Cryogenic System with Neon Turbo-refrigerator for HTS Power Equipment
    Yoshida, S.
    Hirai, H.
    Nara, N.
    Ozaki, S.
    Hirokawa, M.
    Eguchi, T.
    Hayashi, H.
    Iwakuma, M.
    Shiohara, Y.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 1246 - 1253
  • [3] Sub-Cooled Liquid Nitrogen Test System for Cooling HTS Synchronous Motor
    Chen, Anbin
    Xu, Fengyu
    Liu, Xiaokun
    He, Yubao
    Wu, Zonglin
    Zhu, Yingshun
    Han, Zhengnan
    Li, Liyi
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (03)
  • [4] Development of a coreless HTS synchronous generator operating at sub-cooled liquid nitrogen temperatures
    Al-Mosawi, M. K.
    Bailey, W.
    Beduz, C.
    Goddard, K.
    Yang, Y.
    [J]. 8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97
  • [5] Sub-cooled nitrogen cryogenic cooling system for superconducting fault current limiter by using GM-cryocooler
    Kang, H
    Kim, HJ
    Bae, DK
    Ahn, MC
    Chang, HM
    Ko, TK
    [J]. CRYOGENICS, 2005, 45 (01) : 65 - 69
  • [6] Cooling characteristics in long channels with sub-cooled nitrogen
    Fuchino, S.
    Furuse, M.
    Higuchi, N.
    Okano, M.
    Agatsuma, K.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 804 - +
  • [7] CONSIDERATION OF SUB-COOLED LN2 CIRCULATION SYSTEM FOR HTS POWER EQUIPMENT
    Yoshida, S.
    Hirai, H.
    Nara, N.
    Nagasaka, T.
    Hirokawa, M.
    Okamoto, H.
    Hayashi, H.
    Shiohara, Y.
    [J]. ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 1649 - 1656
  • [8] Development of a HTS magnet system for long-run operation test in sub-cooled nitrogen
    Kim, Tae Jung
    Kang, Hyoungku
    Ahn, Min Cheol
    Lee, Chanjoo
    Bae, Duck Kweon
    Seok, Bok-Yeol
    Chang, Ho-Myung
    Ko, Tae Kuk
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) : 1324 - 1327
  • [9] Electrical breakdown characteristics of superconducting magnet system in sub-cooled liquid nitrogen
    Kang, Hyoungku
    Lee, Chanjoo
    Ko, Tae Kuk
    Seok, Bok-Yeol
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 1509 - 1512
  • [10] Size Effect on Breakdown Strength in Sub-cooled Liquid Nitrogen for Superconducting Power Apparatus
    Hayakawa, Naoki
    Nishimachi, Seiichiro
    Kojima, Hiroki
    Okubo, Hitoshi
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (05) : 2565 - 2571