Visual acuity testing in diabetic subjects: the decimal progression chart versus the Freiburg visual acuity test

被引:20
|
作者
Knudsen, LL [1 ]
机构
[1] Aalborg Univ Hosp, Dept Ophthalmol, DK-9000 Aalborg, Denmark
关键词
Visual Acuity; Biological Variation; Macular Oedema; Diabetic Subject; Diabetic Macular Oedema;
D O I
10.1007/s00417-003-0707-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To study reproducibility and biological variation of visual acuity in diabetic maculopathy, using two different visual acuity tests, the decimal progression chart and the Freiburg visual acuity test. Methods. Twenty-two eyes in 11 diabetic subjects were examined several times within a 12-month period using both visual acuity tests. The most commonly used visual acuity test in Denmark (the decimal progression chart) was compared to the Freiburg visual acuity test (automated testing) in a paired study. Results. Correlation analysis revealed agreement between the two methods (r(2)=0.79; slope=0.82; y-axis intercept=0.01). The mean visual acuity was found to be 15% higher (P<0.0001) with the decimal progression chart than with the Freiburg visual acuity test. The reproducibility was the same in both tests (coefficient of variation: 12% for each test); however, the variation within the 12-month examination period differed significantly. The coefficient of variation was 17% using the decimal progression chart, 35% with the Freiburg visual acuity test. Conclusion. The reproducibility of the two visual acuity tests is comparable under optimal testing conditions in diabetic subjects with macular oedema. However, it appears that the Freiburg visual acuity test is significantly better for detection of biological variation.
引用
收藏
页码:615 / 618
页数:4
相关论文
共 50 条
  • [1] Visual acuity testing in diabetic subjects: the decimal progression chart versus the Freiburg visual acuity test
    Lars Loumann Knudsen
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2003, 241 : 615 - 618
  • [2] Calculating the mean visual acuity and the change in visual acuity with a decimal acuity chart
    Touzeau, O
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2003, 26 (06): : 586 - 590
  • [3] Freiburg visual acuity test - automatic measurement of visual acuity
    Bach, Michael
    [J]. Optometry and Vision Science, 1996, 73 (01):
  • [4] The Freiburg Visual Acuity test - Automatic measurement of visual acuity
    Bach, M
    [J]. OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) : 49 - 53
  • [5] Visual acuity measured via the Freiburg Visual Acuity Test (FVT), Bailey Lovie Chart and Landolt Ring Chart
    Wesemann, W
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (09) : 660 - 667
  • [6] The Snellen Chart as a test of visual acuity
    Hetherington, Ralph
    [J]. PSYCHOLOGISCHE FORSCHUNG, 1954, 24 (04): : 349 - 357
  • [7] Visual acuity testing in preschool children: Freiburg acuity test (FrACT) vs LEA symbols test
    Farassat, Navid
    Jehle, Vanessa
    Heinrich, Sven
    Lagreze, Wolf
    Bach, Michael
    [J]. ACTA OPHTHALMOLOGICA, 2024, 102
  • [8] Estimating visual acuity without a visual acuity chart
    Wu, Yueh-Hsun
    Yu, Deyue
    Goldstein, Judith E.
    Kwon, MiYoung
    Watson, Emily Catherine
    Waked, Luc
    Gobeille, Micaela R.
    DeCarlo, Dawn K.
    Gage, Rachel
    Wang, Chun
    Legge, Gordon E.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [9] Quantifying visual acuity in lowest-vision patients using the Freiburg visual acuity test
    Schulze-Bonsel, KS
    Feltgen, N
    Burau, H
    Hansen, LL
    Bach, M
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [10] Comparison of two visual acuity tests in school enrolment examinations. Tumbling E test versus Freiburg visual acuity test
    Bach, M.
    Reuter, M.
    Lagreze, W. A.
    [J]. OPHTHALMOLOGE, 2016, 113 (08): : 684 - 689