Parathyroid Hormone Treatment Increases Fixation of Orthopedic Implants with Gap Healing: A Biomechanical and Histomorphometric Canine Study of Porous Coated Titanium Alloy Implants in Cancellous Bone

被引:28
|
作者
Daugaard, Henrik [1 ]
Elmengaard, Brian [1 ]
Andreassen, Troels [2 ]
Bechtold, Joan [3 ,4 ]
Lamberg, Anders [1 ]
Soballe, Kjeld [1 ]
机构
[1] Aarhus Univ Hosp, Dept Orthopaed, DK-8000 Aarhus, Denmark
[2] Aarhus Univ, Dept Anat, Aarhus, Denmark
[3] Excelen Ctr Bone & Joint Res, Minneapolis, MN USA
[4] Minneapolis Med Res Fdn Inc, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
Parathyroid hormone; Prostheses and implants; Canine; Biomechanics; Histomorphometry; CORTICAL BONE; OVARIECTOMIZED RATS; INTERMITTENT TREATMENT; MECHANICAL STRENGTH; CYNOMOLGUS MONKEYS; HUMAN PTH(1-34); PTH; DENSITY; PARATHYROID-HORMONE-(1-34); OSSEOINTEGRATION;
D O I
10.1007/s00223-010-9458-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Parathyroid hormone (PTH) administered intermittently is a bone-building peptide. In joint replacements, implants are unavoidably surrounded by gaps despite meticulous surgical technique and osseointegration is challenging. We examined the effect of human PTH(1-34) on implant fixation in an experimental gap model. We inserted cylindrical (10 x 6 mm) porous coated titanium alloy implants in a concentric 1-mm gap in normal cancellous bone of proximal tibia in 20 canines. Animals were randomized to treatment with PTH(1-34) 5 mu g/kg daily. After 4 weeks, fixation was evaluated by histomorphometry and push-out test. Bone volume was increased significantly in the gap. In the outer gap (500 mu m), the bone volume fraction median (interquartile range) was 27% (20-37%) for PTH and 10% (6-14%) for control. In the inner gap, the bone volume fraction was 33% (26-36%) for PTH and 13% (11-18%) for control. At the implant interface, the bone fraction improved with 16% (11-20%) for PTH and 10% (7-12%) (P = 0.07) for control. Mechanical implant fixation was improved for implants exposed to PTH. For PTH, median (interquartile range) shear stiffness was significantly higher (PTH 17.4 [12.7-39.7] MPa/mm and control 8.8 [3.3-12.4] MPa/mm) (P < 0.05). Energy absorption was significantly enhanced for PTH (PTH 781 [595-1,198.5] J/m(2) and control 470 [189-596] J/m(2)). Increased shear strength was observed but was not significant (PTH 3.0 [2.6-4.9] and control 2.0 [0.9-3.0] MPa) (P = 0.08). Results show that PTH has a positive effect on implant fixation in regions where gaps exist in the surrounding bone. With further studies, PTH may potentially be used clinically to enhance tissue integration in these challenging environments.
引用
收藏
页码:294 / 303
页数:10
相关论文
共 8 条
  • [1] Parathyroid Hormone Treatment Increases Fixation of Orthopedic Implants with Gap Healing: A Biomechanical and Histomorphometric Canine Study of Porous Coated Titanium Alloy Implants in Cancellous Bone
    Henrik Daugaard
    Brian Elmengaard
    Troels Andreassen
    Joan Bechtold
    Anders Lamberg
    Kjeld Soballe
    Calcified Tissue International, 2011, 88 : 294 - 303
  • [2] Parathyroid hormone enhances gap healing and osseointegration in orthopedic porous coated titanium implants: a correlative micro-computed tomographic, histomorphometric and biomechanical analysis
    Xinlin Gao
    Yang Meng
    Dingjun Hao
    Hao Liu
    BMC Musculoskeletal Disorders, 23
  • [3] Parathyroid hormone enhances gap healing and osseointegration in orthopedic porous coated titanium implants: a correlative micro-computed tomographic, histomorphometric and biomechanical analysis
    Gao, Xinlin
    Meng, Yang
    Hao, Dingjun
    Liu, Hao
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [4] Demineralized bone matrix and human cancellous bone enhance fixation of porous-coated titanium implants in sheep
    Babiker, Hassan
    Ding, Ming
    Overgaard, Soren
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2016, 10 (03) : 245 - 251
  • [5] Systemic intermittent parathyroid hormone treatment improves osseointegration of press-fit inserted implants in cancellous bone A canine study
    Daugaard, Henrik
    Elmengaard, Brian
    Andreassen, Troels Torp
    Lamberg, Anders
    Bechtold, Joan Elisabeth
    Soballe, Kjeld
    ACTA ORTHOPAEDICA, 2012, 83 (04) : 411 - 419
  • [6] Bone morphogenetic protein-2 coating of titanium implants increases biomechanical strength and accelerates bone remodeling in fracture treatment: A biomechanical and histological study in rats
    Schmidmaier, G
    Wildemann, B
    Cromme, F
    Kandziora, F
    Haas, NP
    Raschke, M
    BONE, 2002, 30 (06) : 816 - 822
  • [7] Bone healing, tissue effects and biomechanical fixation of 'smooth' ceramic-coated zirconia-based dental implants: An in vivo study in sheep
    Preiss, Laura
    Chopard-Lallier, Anne-Lise
    Reveron, Helen
    Bruyere-Garnier, Karine
    Adolfsson, Erik
    Kohal, Ralf-Joachim
    Chevalier, Jerome
    Courtois, Nicolas
    OPEN CERAMICS, 2024, 17
  • [8] Porous titanium-coated polyetheretherketone implants exhibit an improved bone-implant interface: an in vitro and in vivo biochemical, biomechanical, and histological study
    Cheng, Boyle C.
    Koduri, Sravanthi
    Wing, Charles A.
    Woolery, Natalie
    Cook, Daniel J.
    Spiro, Robert C.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2018, 11 : 391 - 402