Low-dose-rate iodine-125 seed air kerma strength measurement intercomparison

被引:0
|
作者
Poder, Joel [1 ,2 ]
Smith, Ryan [3 ]
Haworth, Annette [4 ]
机构
[1] St George Hosp, Canc Care Ctr, Kogarah, NSW 2217, Australia
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[3] Alfred Hosp, Alfred Hlth Radiat Oncol, Melbourne, Vic, Australia
[4] Univ Sydney, Sch Phys, Camperdown, NSW, Australia
关键词
I-125; Brachytherapy; Air kerma strength; Calibration; Intercomparison; EMITTING BRACHYTHERAPY SOURCES; RADIATION-THERAPY; RANDOMIZED-TRIAL; CALIBRATION; RECOMMENDATIONS; CHAMBER;
D O I
10.1016/j.brachy.2019.10.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: The purpose of this study was to investigate the rate of compliance of air kerma strength (AKS) measurements of iodine-125 (1-125) seeds with international recommendations by departments in Australia and determine the potential impact of noncompliance. METHODS AND MATERIALS: To achieve this aim, we present an intercomparison of AKS measurements for a single I-125 seed performed by 11 radiotherapy departments in Australia. Measurements were performed at two sites, with each participating department traveling to one of the two host sites and measuring the AKS using their own equipment and local protocols. Each of the AKS measurements was compared with each other and the manufacturer-certified AKS. RESULTS: Nine of the 11 participating departments measured AKS fell within +/- 3% of the manufacturer's calibration certificate value, whereas all participating departments measured AKS within +/- 5% of the manufacturer's calibration certificate value. The total spread of the measured AKS among the 11 departments was 7.7%. Only two of the 11 participating departments complied with international recommendations and had their well chamber calibrated within the last 2 years. In addition, 2 of the 11 departments used a well chamber calibrated that was calibrated with a different seed model used during the intercomparison, whereas 4 of the 11 departments calibrated their well chamber "in-house" using a factory-calibrated seed provided by the seed manufacturer. CONCLUSIONS: A significant variation in the methods used and frequency of calibration of well chambers were observed among the participating departments. The results of this study support the international recommendations on frequency and methodology of well chamber calibration. Failure to follow these recommendations significantly increases the uncertainty in AKS measurement of I-125 seeds. Crown Copyright (C) 2020 Published by Elsevier Inc. on behalf of American Brachytherapy Society. All rights reserved.
引用
收藏
页码:119 / 125
页数:7
相关论文
共 50 条
  • [1] Changes in the tumor microenvironment during low-dose-rate permanent seed implantation iodine-125 brachytherapy
    Cron, GO
    Beghein, N
    Crokart, N
    Chavée, E
    Bernard, S
    Vynckier, S
    Scalliet, P
    Gallez, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (04): : 1245 - 1251
  • [2] Continuous Low-dose-rate Irradiation of Iodine-125 Seeds Inhibiting Perineural Invasion in Pancreatic Cancer
    Zheng Lu
    Teng-Hui Dong
    Pei-Ren Si
    Wei Shen
    Yi-Liang Bi
    Min Min
    Xin Chen
    Yan Liu
    中华医学杂志英文版, 2016, 129 (20) : 2460 - 2468
  • [3] Continuous Low-dose-rate Irradiation of Iodine-125 Seeds Inhibiting Perineural Invasion in Pancreatic Cancer
    Lu, Zheng
    Dong, Teng-Hui
    Si, Pei-Ren
    Shen, Wei
    Bi, Yi-Liang
    Min, Min
    Chen, Xin
    Liu, Yan
    CHINESE MEDICAL JOURNAL, 2016, 129 (20) : 2460 - 2468
  • [4] Radiation proctitis after iodine-125 low-dose-rate prostate brachytherapy utilizing SpaceOAR hydrogel
    Morita, Masashi
    Hiramatsu, Aya
    Nishimura, Kota
    Yanagida, Wahei
    Nakamura, Saori
    Yamatoya, Jin
    Noguchi, Tetsuo
    Tanabe, Mayo
    Fukagai, Takashi
    Lederer, John L.
    INTERNATIONAL JOURNAL OF UROLOGY, 2024, 31 (09) : 1001 - 1008
  • [5] Iodine-125 low-dose rate prostate brachytherapy
    Minami, Takafumi
    Fujimoto, Saizo
    Fujita, Kazutoshi
    INTERNATIONAL JOURNAL OF UROLOGY, 2025, 32 (02) : 130 - 137
  • [6] Combined fractionated external beam radiotherapy and low-dose-rate iodine-125 seeds in an experimental tumor system
    Würschmidt F.
    Faßbender T.
    Beck-Bornholdt H.-P.
    Strahlentherapie und Onkologie, 2000, 176 (11) : 524 - 527
  • [7] Placement of SpaceOAR hydrogel spacer for prostate cancer patients treated with iodine-125 low-dose-rate brachytherapy
    Morita, Masashi
    Fukagai, Takashi
    Hirayama, Kidai
    Yamatoya, Jin
    Noguchi, Tetsuo
    Ogawa, Yu
    Igarashi, Atsushi
    Niiya, Akifumi
    Kato, Masako
    Morota, Madoka
    Oshinomi, Kazuhiko
    Ogawa, Yoshio
    Lederer, John L.
    INTERNATIONAL JOURNAL OF UROLOGY, 2020, 27 (01) : 60 - 66
  • [8] Dosiomic predictors of biochemical failure in patients with localized prostate cancer treated with Iodine-125 low-dose-rate brachytherapy
    Masahiro Nakano
    Shizuo Kaji
    Shogo Kawakami
    Hideyasu Tsumura
    Toshikazu Imae
    Yuichi Tanaka
    Kyohei Fujii
    Takuro Kainuma
    Ryosuke Yamazaki
    Ayaka Uchida
    Hijiri Kaneko
    Mako Fujino
    Chizu Hata
    Yu Murakami
    Masatoshi Hashimoto
    Hiromichi Ishiyama
    Radiation Oncology, 20 (1)
  • [9] Re: Placement of SpaceOAR hydrogel spacer for prostate cancer patients treated with iodine-125 low-dose-rate brachytherapy
    Ghaffari, Hamed
    INTERNATIONAL JOURNAL OF UROLOGY, 2020, 27 (05) : 473 - 473
  • [10] Measurement of the strength of iodine-125 seed moving at unknown speed during implantation in brachytherapy
    Tanaka, Kenichi
    Endo, Satoru
    Tateoka, Kunihiko
    Asanuma, Osamu
    Kamo, Ken-ichi
    Sato, Kaori
    Takeda, Hiromitsu
    Takagi, Masaru
    Hareyama, Masato
    Takada, Jun
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (01) : 162 - 167