The exposure to Th-232 from TIG welding with thoriated electrodes has been determined at five different workshops. Welding with both alternating and direct current was investigated. The exposure levels of Th-232 were generally below 10 mBq m(-3) in the breathing zone of the welders. Two samples from AC welding showed significant higher exposure levels, probably due to maladjustment of the TIG welding power source. Samples of the respirable fraction of Th-232 from grinding thoriated electrodes were also collected showing exposure levels of 5 mBq m(-3) or lower. A dose estimate has been made for two scenarios, one realistic and one with conservative assumptions, showing that the annual committed effective dose from inhalation of Th-232, Th-230, Th-228 and Ra-228, for a full-time TIG welder, in the realistic case is below 0.3 mSv and with conservative assumptions around 1 mSv or lower. The contribution from grinding electrodes was lower, 10 muSv or lower in the realistic case and 63 muSv or lower based on conservative assumptions. The study does not exclude occurrence of higher exposure levels under welding conditions different from those prevailing in this study.
引用
收藏
页码:349 / 357
页数:9
相关论文
共 50 条
  • [1] Thorium exposure during welding and grinding with thoriated tungsten electrodes
    Ludwig, T
    Seitz, G
    [J]. IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D615 - D617
  • [2] Exposures from thorium contained in thoriated tungsten welding electrodes
    Jankovic, JT
    Underwood, WS
    Goodwin, GM
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1999, 60 (03): : 384 - 389
  • [3] Radiation exposure at TIG welding with thoriated tungsten electrodes
    Reichelt, A
    [J]. IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 4, 1996, : D614 - D614
  • [4] Intakes of thorium while using thoriated tungsten electrodes for TIG welding
    Ludwig, T
    Schwass, D
    Seitz, G
    Siekmann, H
    [J]. HEALTH PHYSICS, 1999, 77 (04): : 462 - 469
  • [5] MEASUREMENTS OF AIR CONCENTRATIONS OF THORIUM DURING GRINDING AND WELDING OPERATIONS USING THORIATED TUNGSTEN ELECTRODES
    CRIM, EM
    BRADLEY, TD
    [J]. HEALTH PHYSICS, 1995, 68 (05): : 719 - 722
  • [6] A STUDY OF THORIUM EXPOSURE DURING TUNGSTEN INERT-GAS WELDING IN AN AIRLINE ENGINEERING POPULATION
    MCELEARNEY, N
    IRVINE, D
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1993, 35 (07) : 707 - 711
  • [7] Thorium-232 exposure during tungsten inert gas arc welding and electrode sharpening
    Saito, H
    Hisanaga, N
    Okada, Y
    Hirai, S
    Arito, H
    [J]. INDUSTRIAL HEALTH, 2003, 41 (03) : 273 - 278
  • [8] Radiation exposure during professional TIG-welding using thoriated tungsten electrodes
    Sternad, T
    Kratzel, U
    [J]. RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 27 - 32
  • [9] Welding with non-consumable thoriated tungsten electrodes
    Costa, Luca
    [J]. WELDING IN THE WORLD, 2015, 59 (01) : 145 - 150
  • [10] Welding with non-consumable thoriated tungsten electrodes
    Luca Costa
    [J]. Welding in the World, 2015, 59 : 145 - 150