Gases for establishing pneumoperitoneum during laparoscopic abdominal surgery

被引:21
|
作者
Yu, Tianwu [1 ]
Cheng, Yao [2 ]
Wang, Xiaomei [2 ]
Tu, Bing [2 ]
Cheng, Nansheng [3 ]
Gong, Jianping [2 ]
Bai, Lian [4 ]
机构
[1] Chongqing Med Univ, Yongchuan Hosp, Dept Hepatobiliary Surg, Chongqing, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 2, Dept Hepatobiliary Surg, Chongqing, Peoples R China
[3] Sichuan Univ, West China Hosp, Dept Bile Duct Surg, Chengdu, Sichuan, Peoples R China
[4] Chongqing Med Univ, Yongchuan Hosp, Dept Gastrointestinal Surg, 439 Quxuanhua Rd, Chongqing 402160, Peoples R China
关键词
Carbon Dioxide [adverse effects; Helium [adverse effects; Nitrous Oxide [adverse effects; Abdomen [surgery; Laparoscopy [methods; Pneumoperitoneum; Artificial [adverse effects; methods; Humans; CARBON-DIOXIDE PNEUMOPERITONEUM; CLINICALLY IMPORTANT DIFFERENCE; TRIAL SEQUENTIAL-ANALYSIS; NITROUS-OXIDE; HELIUM INSUFFLATION; INFORMATION SIZE; CHOLECYSTECTOMY; PAIN; COMPLICATIONS; CO2;
D O I
10.1002/14651858.CD009569.pub3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This is an update of the review published in 2013. Laparoscopic surgery is now widely performed to treat various abdominal diseases. Currently, carbon dioxide is the most frequently used gas for insufflation of the abdominal cavity (pneumoperitoneum). Although carbon dioxide meets most of the requirements for pneumoperitoneum, the absorption of carbon dioxide may be associated with adverse events. People with high anaesthetic risk are more likely to experience cardiopulmonary complications and adverse events, for example hypercapnia and acidosis, which has to be avoided by hyperventilation. Therefore, other gases have been introduced as alternatives to carbon dioxide for establishing pneumoperitoneum. Objectives To assess the safety, benefits, and harms of different gases (i.e. carbon dioxide, helium, argon, nitrogen, nitrous oxide, and room air) used for establishing pneumoperitoneum in participants undergoing laparoscopic general abdominal or gynaecological pelvic surgery. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2016, Issue 9), OvidMEDLINE (1950 to September 2016), Ovid Embase (1974 to September 2016), Science Citation Index Expanded (1970 to September 2016), Chinese Biomedical Literature Database (CBM) (1978 to September 2016), ClinicalTrials. gov (September 2016), and World Health Organization International Clinical Trials Registry Platform (September 2016). Selection criteria We included randomised controlled trials (RCTs) comparing different gases for establishing pneumoperitoneum in participants (irrespective of age, sex, or race) undergoing laparoscopic abdominal or gynaecological pelvic surgery under general anaesthesia. Data collection and analysis Two review authors identified the trials for inclusion, collected the data, and assessed the risk of bias independently. We performed the meta-analyses using Review Manager 5. We calculated risk ratio (RR) for dichotomous outcomes (or Peto odds ratio for very rare outcomes), and mean difference (MD) or standardised mean difference (SMD) for continuous outcomes with 95% confidence intervals (CI). We used GRADE to rate the quality of evidence, Main results We included nine RCTs, randomising 519 participants, comparing different gases for establishing pneumoperitoneum: nitrous oxide (three trials), helium (five trials), or room air (one trial) was compared to carbon dioxide. Three trials randomised participants to nitrous oxide pneumoperitoneum (100 participants) or carbon dioxide pneumoperitoneum (96 participants). None of the trials was at low risk of bias. There was insufficient evidence to determine the effects of nitrous oxide and carbon dioxide on cardiopulmonary complications (RR 2.00, 95% CI 0.38 to 10.43; two studies; 140 participants; very low quality of evidence), or surgical morbidity (RR 1.01, 95% CI 0.18 to 5.71; two studies; 143 participants; very low quality of evidence). There were no serious adverse events related to either nitrous oxide or carbon dioxide pneumoperitoneum (three studies; 196 participants; very low quality of evidence). We could not combine data from two trials (140 participants) which individually showed lower pain scores (a difference of about one visual analogue score on a scale of 1 to 10 with lower numbers indicating less pain) with nitrous oxide pneumoperitoneum at various time points on the first postoperative day, and this was rated asvery low quality. Four trials randomised participants to helium pneumoperitoneum (69 participants) or carbon dioxide pneumoperitoneum (75 participants) and one trial involving 33 participants did not state the number of participants in each group. None of the trials was at low risk of bias. There was insufficient evidence to determine the effects of helium or carbon dioxide on cardiopulmonary complications (RR 1.46, 95% CI 0.35 to 6.12; three studies; 128 participants; very low quality of evidence) or pain scores (visual analogue score on a scale of 1 to 10 with lower numbers indicating less pain; MD 0.49 cm, 95% CI - 0.28 to 1.26; two studies; 108 participants; very low quality of evidence). There were three serious adverse events (subcutaneous emphysema) related to helium pneumoperitoneum (three studies; 128 participants; very low quality of evidence). One trial randomised participants to room air pneumoperitoneum (70 participants) or carbon dioxide pneumoperitoneum (76 participants). The trial was at unclear risk of bias. There were no cardiopulmonary complications or serious adverse events observed related to either room air or carbon dioxide pneumoperitoneum (both outcomes very low quality of evidence). The evidence of lower hospital costs and reduced pain during the first postoperative day with room air pneumoperitoneum compared with carbon dioxide pneumoperitoneum (a difference of about one visual analogue score on a scale of 1 to 10 with lower numbers indicating less pain, was rated as very low quality of evidence. Authors' conclusions The quality of the current evidence is very low. The effects of nitrous oxide and helium pneumoperitoneum compared with carbon dioxide pneumoperitoneum are uncertain. Evidence from one trial of small sample size suggests that room air pneumoperitoneum may decrease hospital costs in people undergoing laparoscopic abdominal surgery. The safety of nitrous oxide, helium, and room air pneumoperitoneum has yet to be established. Further trials on this topic are needed, and should compare various gases (i.e. nitrous oxide, helium, argon, nitrogen, and roomair) with carbon dioxide under standard pressure pneumoperitoneum with cold gas insufflation for people with high anaesthetic risk. Future trials should include outcomes such as complications, serious adverse events, quality of life, and pain.
引用
收藏
页数:85
相关论文
共 50 条
  • [1] Gases for establishing pneumoperitoneum during laparoscopic abdominal surgery
    Cheng, Yao
    Lu, Jiong
    Xiong, Xianze
    Wu, Sijia
    Lin, Yixin
    Wu, Taixiang
    Cheng, Nansheng
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (01):
  • [2] Gases for establishing pneumoperitoneum during laparoscopic abdominal surgery
    Yang, Xudong
    Cheng, Yao
    Cheng, Nansheng
    Gong, Jianping
    Bai, Lian
    Zhao, Longshuan
    Deng, Yilei
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2022, (03):
  • [3] Effect of depth of neuromuscular blockade on the abdominal space during pneumoperitoneum establishment in laparoscopic surgery
    Barrio, Javier
    Errando, Carlos L.
    San Miguel, Guillermo
    Salas, Boris I.
    Raga, Juan
    Carrion, Jose L.
    Garcia-Ramon, Jaime
    Gallego, Juan
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 197 - 203
  • [4] A novel and easily reproducible method for re-establishing pneumoperitoneum during laparoscopic colorectal resectional surgery
    Mobasheri, M.
    Khatri, K.
    Gudgeon, M.
    Sains, P.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2012, 94 (04) : 276 - 276
  • [5] Bayesian hierarchical nonlinear modelling of intra-abdominal volume during pneumoperitoneum for laparoscopic surgery
    Calvo, Gabriel
    Armero, Carmen
    Gomez-Rubio, Virgilio
    Mazzinari, Guido
    SORT-STATISTICS AND OPERATIONS RESEARCH TRANSACTIONS, 2021, 45 (02) : 143 - 162
  • [6] Pulmonary function alteration in laparoscopic surgery with pneumoperitoneum and abdominal wall elevation
    dos Reis Falcao, Luiz Fernando
    Leite Battisti, Fabricio de Paula
    de Oliveira, Itamar Souza
    Ferez, David
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2018, 68 (02): : 215 - 216
  • [7] Hemodynamic effects of pneumoperitoneum during gynecologic laparoscopic surgery
    Carter, JF
    Chang, EY
    Haynes, G
    Scardo, JA
    JOURNAL OF GYNECOLOGIC SURGERY, 1997, 13 (04) : 169 - 173
  • [8] Influences of pneumoperitoneum on tissue oxygenation during laparoscopic abdominal surgery in normal weight and morbidly obese patients
    Fleischmann, E.
    Kabon, B.
    Niedermayr, M.
    Kimberger, O.
    Kurz, A.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 61 - 61
  • [9] Bayesian Growth Curve Model for Studying the Intra-abdominal Volume During Pneumoperitoneum for Laparoscopic Surgery
    Calvo, Gabriel
    Armero, Carmen
    Gomez-Rubio, Virgilio
    Mazzinari, Guido
    NEW FRONTIERS IN BAYESIAN STATISTICS, BAYSM 2021, 2022, 405 : 111 - 116
  • [10] Effects of Pneumoperitoneum on Splanchnic Oxygenation during Abdominal Laparoscopic Surgery in Paediatric Patients: A prospective, Observational Study
    Kilinc, Leyla
    Turk, Hacer Sebnem
    Sayin, Pinar
    Cinar, Surhan
    Demir, Mesut
    Islamoglu, Serkan
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2021, 49 (02) : 138 - 143