Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics

被引:78
|
作者
Jonnal, Ravi S. [1 ]
Kocaoglu, Omer P. [2 ]
Wang, Qiang [2 ]
Lee, Sangyeol [2 ]
Miller, Donald T. [1 ,2 ]
机构
[1] Indiana Univ, Program Vis Sci, Bloomington, IN 47405 USA
[2] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2012年 / 3卷 / 01期
关键词
HUMAN CONE PHOTORECEPTORS; IN-VIVO; HIGH-RESOLUTION; MICROSCOPY; RENEWAL; FLOW;
D O I
10.1364/BOE.3.000104
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The cone photoreceptor's outer segment (OS) experiences changes in optical path length, both in response to visible stimuli and as a matter of its daily course of renewal and shedding. These changes are of interest, to quantify function in healthy cells and assess dysfunction in diseased ones. While optical coherence tomography (OCT), combined with adaptive optics (AO), has permitted unprecedented three-dimensional resolution in the living retina, it has not generally been able to measure these OS dynamics, whose scale is smaller than OCT's axial resolution of a few microns. A possible solution is to take advantage of the phase information encoded in the OCT signal. Phase-sensitive implementations of spectral-domain optical coherence tomography (SD-OCT) have been demonstrated, capable of resolving sample axial displacements much smaller than the imaging wavelength, but these have been limited to ex vivo samples. In this paper we present a novel technique for retrieving phase information from OCT volumes of the outer retina. The key component of our technique is quantification of phase differences within the retina. We provide a quantitative analysis of such phase information and show that-when combined with appropriate methods for filtering and unwrapping-it can improve the sensitivity to OS length change by more than an order of magnitude, down to 45 nm, slightly thicker than a single OS disc. We further show that phase sensitivity drops off with retinal eccentricity, and that the best location for phase imaging is close to the fovea. We apply the technique to the measurement of sub-resolution changes in the OS over matters of hours. Using custom software for registration and tracking, these microscopic changes are monitored in hundreds of cones over time. In two subjects, the OS was found to have average elongation rates of 150 nm/hr, values which agree with our previous findings. (C) 2011 Optical Society of America
引用
收藏
页码:104 / 124
页数:21
相关论文
共 50 条
  • [1] Imaging retinal function with phase-sensitive adaptive optics optical coherence tomography
    Kurokawa, Kazuhiro
    Crowell, James A.
    Zhang, Furu
    Liu, Zhuolin
    Miller, Donald Thomas
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [2] Adaptive optics optical coherence tomography for retina imaging
    史国华
    戴云
    王玲
    丁志华
    饶学军
    张雨东
    [J]. Chinese Optics Letters, 2008, (06) : 424 - 425
  • [3] Adaptive optics optical coherence tomography for retina imaging
    Shi, Guohua
    Dai, Yun
    Wang, Ling
    Ding, Zhihua
    Rao, Xuejun
    Zhang, Yudong
    [J]. CHINESE OPTICS LETTERS, 2008, 6 (06) : 424 - 425
  • [4] Intrasweep phase-sensitive optical coherence tomography for noncontact optical photoacoustic imaging
    Blatter, Cedric
    Grajciar, Branislav
    Zou, Pu
    Wieser, Wolfgang
    Verhoef, Aart-Jan
    Huber, Robert
    Leitgeb, Rainer A.
    [J]. OPTICS LETTERS, 2012, 37 (21) : 4368 - 4370
  • [5] Imaging photoreceptor response in rodent eyes using phase-sensitive optical coherence tomography
    Tan, Bingyao
    Li, Huakun
    Barathi, Veluchamy A.
    Schmetterer, Leopold
    Ling, Tong
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [6] Optical coherence tomography with phase-sensitive light
    Erkmen, Baris I.
    Shapiro, Jeffrey H.
    [J]. QUANTUM COMMUNICATIONS AND QUANTUM IMAGING IV, 2006, 6305
  • [7] Volumetric imaging of inner retina with adaptive optics spectraldomain optical coherence tomography
    Zhang, Yan
    Cense, Barry
    Jonnal, Ravi S.
    Gao, Weihua
    Jones, Steve
    Olivier, Scot
    Miller, Donald T.
    [J]. OPHTHALMIC TECHNOLOGIES XVII, 2007, 6426
  • [8] Optical coherence tomography for an adaptive optics retina camera
    Miller, DT
    Qu, JL
    Jonnal, RS
    Zhao, HW
    [J]. OPTICS FOR THE QUALITY OF LIFE, PTS 1 AND 2, 2003, 4829 : 641 - 643
  • [9] Imaging the mouse retina in vivo using Adaptive Optics - Fourier Domain Optical Coherence Tomography
    Jian, Yifan
    Werner, John
    Wong, Kevin
    Pugh, Edward
    Sarunic, Marinko
    Zawadzki, Robert
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [10] Optical inspection of solar cells using phase-sensitive optical coherence tomography
    Tsai, Meng-Tsan
    Chang, Feng-Yu
    Yao, Yung-Chi
    Mei, Jie
    Lee, Ya-Ju
    [J]. SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2015, 136 : 193 - 199