Adequacy of the epinephrine autoinjector needle length in delivering epinephrine to the intramuscular tissues

被引:89
|
作者
Song, TT
Nelson, MR
Chang, JH
Engler, RJM
Chowdhury, BA
机构
[1] Walter Reed Army Med Ctr, Dept Allergy & Immunol, Washington, DC 20307 USA
[2] Walter Reed Army Med Ctr, Dept Radiol, Washington, DC 20307 USA
关键词
D O I
10.1016/S1081-1206(10)61130-1
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Epinephrine injected by an autoinjector in the anterolateral aspect of the thigh is the standard of care in the emergency self-treatment of anaphylaxis. In the United States, the autoinjector EpiPen is widely used for the self-treatment of anaphylaxis. Objective: To investigate whether EpiPen autoinjector, with a needle length of 1.43 cm, is sufficient for intramuscular delivery of epinephrine in men and women. Methods: The distance from skin to muscle in the anterolateral aspect of the thigh was measured in 50 men and 50 women who had undergone computed tomography of the thighs for other medical reasons. For each individual, body mass index (BMI; a measure of weight in kilograms divided by the square of height in meters) was also calculated, and the individuals were classified as underweight (BMI, < 18.5), normal (BMI, 18.5-24.9), overweight (BMI, 25.0-29.9), and obese (BMI, >= 30.0) using standard definition. Results: In the study participants the mean +/- SD distance from skin to muscle was 0.66 +/- 0.47 cm for men and 1.48 +/- 0.72 cm for women (P <.001). One man (obese at a BMI of 42.2) and 21 women (I I obese with a mean BMI of 35.2, 6 overweight with a mean BMI of 30.1, and 4 normal with a mean BMI of 24.5) had a greater distance from skin to muscle than the EpiPen needle length of 1.43 cm. Conclusion: The distance from skin to muscle for the anterolateral aspect of the thigh is higher in women compared with men. This difference suggests that EpiPen may not deliver epinephrine to the intramuscular tissue in many women.
引用
收藏
页码:539 / 542
页数:4
相关论文
共 50 条
  • [1] Predictors of epinephrine autoinjector needle length inadequacy
    Bhalla, Mary Colleen
    Gable, Brad D.
    Frey, Jennifer A.
    Reichenbach, Matthew R.
    Wilber, Scott T.
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (12): : 1671 - 1676
  • [2] Predictors of epinephrine autoinjector needle length inadequacy
    Song, T. Ted
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (05): : 473 - 474
  • [3] A pilot study assessing adequacy of epinephrine autoinjector needle length to deliver epinephrine intramuscularly in adult patients with food and venom allergy
    Tsai, G.
    Kim, L.
    Dominic, A.
    Nevis, I. F.
    Potts, R.
    Chiu, J.
    Kim, H.
    [J]. ALLERGY, 2013, 68 : 569 - 569
  • [4] Response to comments on "Predictors of epinephrine autoinjector needle length inadequacy"
    Bhalla, Mary Colleen
    [J]. AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2014, 32 (05): : 474 - 474
  • [5] Inadequacy of current pediatric epinephrine autoinjector needle length for use in infants and toddlers
    Kim, Harold
    Dinakar, Chitra
    McInnis, Paul
    Rudin, Dan
    Benain, Xavier
    Daley, William
    Platz, Elke
    [J]. ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2017, 118 (06) : 719 - +
  • [6] Pharmacokinetic Profile of Epinephrine Nasal Spray Versus Intramuscular Epinephrine Autoinjector in Healthy Adults
    Greenhawt, Matthew
    Bernstein, David
    Blaiss, Michael
    Dubuske, Lawrence
    Fleischer, David
    Lieberman, Jay
    Oppenheimer, John
    Dworaczyk, David
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2024, 153 (02) : AB13 - AB13
  • [7] Epinephrine Autoinjector Warning
    Hawkins, Seth C.
    Weil, Carl
    Fitzpatrick, David
    [J]. WILDERNESS & ENVIRONMENTAL MEDICINE, 2012, 23 (04) : 371 - 372
  • [8] Epinephrine autoinjector survey
    Al-Selahi, E.
    Cisneros, N.
    [J]. ALLERGY, 2010, 65 : 142 - 142
  • [9] Epinephrine autoinjectors The needle length matters
    Dreborg, Sten
    Kim, Harold
    [J]. ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 2020, 124 (05) : 449 - 450
  • [10] Updated epinephrine autoinjector labeling
    Dinakar, Chitra
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE, 2016, 4 (05): : 1020 - 1021