共 29 条
Application of infrared portable sensor technology for predicting perceived astringency of acidic whey protein beverages
被引:8
|作者:
Wang, Ting
[1
]
Tan, Siow-Ying
[2
]
Mutilangi, William
[2
]
Plans, Marcal
[1
]
Rodriguez-Saona, Luis
[1
]
机构:
[1] Ohio State Univ, Dept Food Sci & Technol, Columbus, OH 43210 USA
[2] Pepsi Cola Co, Valhalla, NY 10595 USA
关键词:
whey protein;
acidic beverages;
astringency;
infrared spectroscopy;
chemometrics;
MIDINFRARED SPECTROSCOPY;
LOW PH;
QUANTITATIVE-ANALYSIS;
SALIVARY PROTEINS;
MILK;
SPECTRA;
SPECTROMETERS;
CHEMOMETRICS;
PARAMETERS;
QUALITY;
D O I:
10.3168/jds.2016-11411
中图分类号:
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号:
0905 ;
摘要:
Formulating whey protein beverages at acidic pH provides better clarity but the beverages typically develop an unpleasant and astringent flavor. Our aim was to evaluate the application of infrared spectroscopy and chemometrics in predicting astringency of acidic whey protein beverages. Whey protein isolate (WPI), whey protein concentrate (WPC), and whey protein hydrolysate (WPH) from different manufacturers were used to formulate beverages at pH ranging from 2.2 to 3.9. Trained panelists using the spectrum. method of descriptive analysis tested the beverages providing astringency scores. A portable Fourier transform infrared spectroscopy attenuated total reflectance spectrometer was used for spectra collection that was analyzed by multivariate regression analysis (partial least squares regression) to build calibration models with the sensory astringency scores. Beverage astringency scores fluctuated from 1.9 to 5.2 units and were explained by pH, protein type (WPC, WPI, or WPH), source (manufacturer), and their interactions, revealing the complexity of astringency development in acidic whey protein beverages. The WPC and WPH beverages showed an increase in astringency as the pH of the solution was lowered, but no relationship was found for WPI beverages. The partial least squares regression analysis showed strong relationship between the reference astringency scores and the infrared predicted values (correlation coefficient >0.94), giving standard error of cross-validation ranging from 0.08 to 0.12 units., depending on whey protein type. Major absorption bands explaining astringency scores were associated with carboxylic groups and amide regions of proteins. The portable infrared technique allowed rapid prediction of astringency of acidic whey protein beverages, providing the industry a novel tool for monitoring sensory characteristics of whey-containing beverages.
引用
收藏
页码:9461 / 9470
页数:10
相关论文