CIGRE WG 13.06 studies on the reliability of single pressure SF6-gas high-voltage circuit-breakers

被引:8
|
作者
Janssen, ALJ
Brunke, JH
Heising, CR
Lanz, W
机构
[1] BONNEVILLE POWER ADM,SALT LAKE CITY,UT
[2] ABB HOCHSPANNUNGSTECH AKTIENGESELL,DEV LABS,ZURICH,SWITZERLAND
关键词
D O I
10.1109/61.484026
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The final results of the CIGRE second international enquiry on the reliability of high voltage circuit-breakers in service are presented. In the seventies the first international enquiry, that covered all technology circuit-breakers, was conducted. The second international enquiry (from 1.1.88 to 31.12.91) was limited to single pressure SF6 gas circuit-breakers, thus showing the improvements due to this technology. The main conclusion is that the reliability concerning Major Failures has increased considerably and that the maintainability of modern SF6 circuit-breakers is much better than the older technology circuit-breakers. Also the conclusions from several other studies, based on the results of the enquiries, are presented. The publication of this paper, as a result of an international effort by CIGRE SC 13, is sponsored here by the IEEE Switchgear Committee in order to support this valuable contribution to the industry and to continue the cooperation between the two organizations.
引用
收藏
页码:274 / 282
页数:9
相关论文
共 50 条
  • [1] RELIABILITY OF HIGH-VOLTAGE CIRCUIT-BREAKERS
    HOFFMANN, D
    [J]. ELEKTROTECHNISCHE ZEITSCHRIFT-ETZ, 1979, 100 (16-1): : 896 - 900
  • [2] RELIABILITY OF HIGH-VOLTAGE CIRCUIT-BREAKERS
    KOPPL, G
    ERNI, H
    [J]. BROWN BOVERI REVIEW, 1973, 60 (04): : 128 - 133
  • [3] MAINTENANCE OF GAS-INSULATED, HIGH-VOLTAGE SWITCHGEAR AND SF6 OUTDOOR CIRCUIT-BREAKERS
    KRENICKY, A
    STELZER, R
    ZELLER, N
    [J]. BROWN BOVERI REVIEW, 1980, 67 (04): : 244 - 250
  • [4] SWITCHING HIGH-VOLTAGE MOTORS WITH SF6 SELF-EXTINGUISHING CIRCUIT-BREAKERS
    GANZ, A
    JAKOB, R
    [J]. BROWN BOVERI REVIEW, 1979, 66 (11): : 710 - 714
  • [5] Performance of SF6 gas mixtures in high-voltage circuit breakers
    Knobloch, H
    Habedank, BU
    [J]. GASEOUS DIELECTRICS IX, 2001, : 455 - 460
  • [6] CIRCUIT-BREAKERS AND THE OPERATION OF HIGH-VOLTAGE NETWORKS
    HINTERTHUR, KH
    KARRENBAUER, H
    [J]. ETZ ARCHIV, 1980, 2 (08): : 219 - 225
  • [7] ACOUSTIC DIAGNOSIS OF HIGH-VOLTAGE CIRCUIT-BREAKERS
    RUNDE, M
    AURUD, T
    LUNDGAARD, LE
    OTTESEN, GE
    FAUGSTAD, K
    BOGGS, SA
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (03) : 1306 - 1315
  • [8] RECOVERY STRENGTH OF HIGH-VOLTAGE CIRCUIT-BREAKERS
    SHILIN, NV
    NIKUEV, YA
    [J]. ELECTRICAL TECHNOLOGY, 1984, (01): : 55 - 65
  • [9] OUTDOOR HIGH-VOLTAGE SF6 CIRCUIT-BREAKERS TYPE ELF FOR MEDIUM BREAKING CAPACITY
    STELZER, R
    RAPPANGE, A
    GAUPP, O
    [J]. BROWN BOVERI REVIEW, 1977, 64 (05): : 268 - 276
  • [10] EARTHQUAKE-PROOF HIGH-VOLTAGE CIRCUIT-BREAKERS
    EGGERT, H
    KUGLER, R
    [J]. SIEMENS REVIEW, 1977, 44 (09): : 383 - 390