Arthroscopic Suture Fixation of Os Acetabuli With Absorbable Suture Anchors-A Double-Pulley Technique

被引:1
|
作者
Yin, Qing-Feng [1 ]
Liu, Wen-Guang [1 ]
Fu, Ying-Qiang [1 ,2 ]
机构
[1] Shandong Univ, Hosp 2, Dept Orthoped, 247 Beiyuan St, Jinan 250033, Peoples R China
[2] Shandong Univ, Cheeloo Coll Med, Jinan, Peoples R China
来源
ARTHROSCOPY TECHNIQUES | 2022年 / 11卷 / 08期
关键词
STRESS-FRACTURE;
D O I
10.1016/j.eats.2022.03.041
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Os acetabuli is a bone fragment with unknown origin and isolated at the acetabular rim that may be associated with cam-type femoroacetabular impingement. If this bone fragment is too large and threatens the stability of the hip joint after resection, fixation would be recommended. However, conventional rigid fixation with metal screws has some disadvantages. We describe an arthroscopic suture fixation of the Os acetabulum with absorbable anchors penetrating the bone fragment and secured by tying knots in a double-pulley fashion simultaneously. This technique provides a new feasible solution for the fixation of Os acetabuli, avoiding any metal implants and potential damage to the joint.
引用
收藏
页码:E1493 / E1498
页数:6
相关论文
共 50 条
  • [1] Arthroscopic double-pulley suture-bridge technique for rotator cuff repair
    Kyung Cheon Kim
    Kwang Jin Rhee
    Hyun Dae Shin
    [J]. Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 1335 - 1338
  • [2] Arthroscopic double-pulley suture-bridge technique for rotator cuff repair
    Kim, Kyung Cheon
    Rhee, Kwang Jin
    Shin, Hyun Dae
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (11) : 1335 - 1338
  • [3] Arthroscopic Fixation of Os Acetabuli and Labral Repair: Suture-on-Screw Technique
    DeFroda, Steven F.
    Wichman, Daniel
    Browning, Robert
    Alter, Thomas D.
    Nho, Shane J.
    [J]. ARTHROSCOPY TECHNIQUES, 2021, 10 (06): : E1491 - E1496
  • [4] Arthroscopic Double-Pulley Suture-Bridge Repair of Supraspinatus Tendon Tear
    Huang, Peiguan
    Tang, Xiaojun
    [J]. ARTHROSCOPY TECHNIQUES, 2024, 13 (01):
  • [5] Modified Double-Pulley And Rip-Stop Suture Bridge Technique In Arthroscopic Rotator Cuff Repair
    Fang, Chi-Jung
    Wang, Jou-Hua
    Su, Wei-Ren
    Kuan, Fa-Chuan
    Hong, Chih-Kai
    Hsu, Kai-Lan
    [J]. ARTHROSCOPY TECHNIQUES, 2023, 12 (02): : e301 - e305
  • [6] Arthroscopic Absorbable Suture Fixation for Tibial Spine Fractures
    Verdano, Michele Arcangelo
    Pellegrini, Andrea
    Lunini, Enricomaria
    Tonino, Pietro
    Ceccarelli, Francesco
    [J]. ARTHROSCOPY TECHNIQUES, 2014, 3 (01): : E45 - E48
  • [7] Arthroscopic Coracoclavicular Fixation Technique Using Multiple All-Suture Anchors
    Jeong, Jeung Yeol
    Yoo, Yon-Sik
    Lee, Seung-Jin
    Im, Wooyoung
    [J]. ARTHROSCOPY TECHNIQUES, 2019, 8 (04): : E423 - E427
  • [8] Use of a Knotless Suture Anchor to Perform Double-Pulley Capsulotenodesis of Infraspinatus
    Ratner, Drew A.
    Rogers, Jason P.
    Tokish, John M.
    [J]. ARTHROSCOPY TECHNIQUES, 2018, 7 (05): : E485 - +
  • [9] Non-absorbable Suture-Loaded Anchors for Finger Pulley Reconstruction
    Fontan, Francisco Rodriguez
    Laynes, Renzo
    Scott, Frank
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [10] Arthroscopic Modified Double-Pulley Suture-Bridge Repair of Medium-Sized Supraspinatus Tendon Tears
    Huang, Peiguan
    Wang, Xiaoxu
    He, Chunrong
    Peng, Bin
    [J]. ARTHROSCOPY TECHNIQUES, 2024, 13 (06):