CONCEPTS OF DAMPERS FOR EARTHQUAKE PROTECTION OF EXISTING BUILDINGS AND FOR DISPLACEMENTS RESTRAINTS IN SEISMICALLY ISOLATED BUILDINGS

被引:0
|
作者
Melkumyan, Mikayel G. [1 ]
机构
[1] Armenian Assoc Earthquake Engn, 1 Charents Str, Yerevan 0025, Armenia
关键词
Tuned Mass Damper; Isolated Upper Floor; Structural Concept; Earthquake Response Analysis; Dynamic Tests; First Application;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Tuned Mass Damper (TMD) is one of the methods, known as a passive vibroprotecting device. The attempt to find the optimal parameters of TMD in the form of an additional flexible upper tenth floor (AFUF) in a 9-story frame building is presented. The efficiency of a single mass damper tuned to the first mode of building vibration is not very high. Therefore, three dampers tuned to the first three vibrations modes of the building are considered much more effective. However, solution of TMD in the form of AFUF contains some deficiencies, which are described in the paper. Therefore, the author has suggested providing flexibility to the damper using laminated rubber-steel bearings. In such case the AFUF will turn into an additional isolated upper floor (AIUF). Results of the earthquake response analyses and of dynamic testing of the existing 9-story apartment frame building before and after erection of AIUF are given. Paper also presents a new concept of dynamic damper (DD) to restrict the displacements of seismically isolated buildings. Since the maximum displacement occurs at the level of isolators the proposed damper as a mass-spring subsystem attached either above or below the isolation interface. It is suggested to use the pavement around the building to create the damper in low-story structures. Other variant of damper is suggested for the large multistory buildings. In both cases the spring of the damper is represented by laminated rubber bearings, which work in one case under the tension and in another under the compression forces. First real application of DD in construction of,a seismically isolated residential house is described in the paper.
引用
收藏
页码:144 / 155
页数:12
相关论文
共 50 条
  • [1] Simulation of the earthquake-induced pounding of seismically isolated buildings
    Komodromos, Petros
    COMPUTERS & STRUCTURES, 2008, 86 (7-8) : 618 - 626
  • [2] Effectiveness of non-linear fluid viscous dampers in seismically isolated buildings
    Guler, Elif
    Alhan, Cenk
    EARTHQUAKES AND STRUCTURES, 2019, 17 (02) : 191 - 204
  • [3] Earthquake-Resilient Design of Seismically Isolated Buildings: A Review of Technology
    Yenidogan, Cem
    VIBRATION, 2021, 4 (03): : 602 - 647
  • [4] Observed behavior of seismically isolated buildings
    Stewart, JP
    Conte, JP
    Aiken, ID
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1999, 125 (09): : 955 - 964
  • [5] DESIGN EXPERIENCE ON SEISMICALLY ISOLATED BUILDINGS
    GIULIANI, GC
    NUCLEAR ENGINEERING AND DESIGN, 1991, 127 (03) : 349 - 366
  • [6] Observed behavior of seismically isolated buildings
    Stewart, Jonathan P.
    Conte, Joel P.
    Aiken, Ian D.
    Journal of Structural Engineering, 1999, 125 (09): : 955 - 964
  • [7] Earthquake Protection of Buildings
    Schwinner, R.
    PETERMANNS MITTEILUNGEN, 1928, 74 (7-8): : 239 - 239
  • [8] Simulating seismically isolated buildings under earthquake-induced pounding incidences
    Polycarpou, P. C.
    Komodromos, P.
    STRUCTURES UNDER SHOCK AND IMPACT XI, 2010, 113 : 245 - 256
  • [9] Observed behavior of buildings seismically isolated with CSSs under a low energy earthquake
    Federico Scafati
    Chiara Ormando
    Paolo Clemente
    Giovanni Bongiovanni
    Journal of Civil Structural Health Monitoring, 2022, 12 : 225 - 243
  • [10] Observed behavior of buildings seismically isolated with CSSs under a low energy earthquake
    Scafati, Federico
    Ormando, Chiara
    Clemente, Paolo
    Bongiovanni, Giovanni
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2022, 12 (02) : 225 - 243