The Efficiency of the Ventilated Gap of the Double-Skin Facade Systems Using Fire Crosscuts

被引:2
|
作者
Barabash, Aleksandra [1 ]
Naumova, Elizaveta [1 ]
Zhuvak, Oksana [1 ]
Nemova, Darya [1 ]
Olshevskiy, Vyacheslav [1 ]
机构
[1] Peter Great St Petersburg Polytech Univ, Politech Skaya Str 29, St Petersburg 195251, Russia
关键词
D O I
10.1051/matecconf/20167302006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Double-skin facade is an excellent material for decoration of buildings. Despite the large number of advantages over other types of finishes, ventilated facades also have their drawbacks. In particular, a violation of installation conditions and fire safety regulations can lead to serious consequences. Innovative materials and structures in the field of fire safety are analyzed in this paper. The article deals with fire protection methods, special attention is given to the unit of fire crosscuts in the air gap of double-skin facade. Analysis of experimental data has revealed some drawbacks of this method and the necessity of design improvements.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Modeling and Simulation of Ventilated Double-Skin Facade Using EnergyPlus
    Le, Sha
    Chen, Youming
    Bi, Yuan
    Lu, Xiang
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 3: BUILDING SIMULATION AND INFORMATION MANAGEMENT, 2014, 263 : 241 - 252
  • [2] Thermal behaviour and efficiency of ventilated double-skin facade in Polish climatic conditions
    Heim, D.
    Janicki, M.
    [J]. RESEARCH ON BUILDING PHYSICS, 2010, : 257 - 263
  • [3] Naturally ventilated double-skin facade in modeling and experiments
    Dama, Alessandro
    Angeli, Diego
    Larsen, Olena Kalyanova
    [J]. ENERGY AND BUILDINGS, 2017, 144 : 17 - 29
  • [4] Naturally ventilated double-skin facade with adjustable louvers
    Tao, Yao
    Fang, Xiang
    Setunge, Sujeeva
    Tu, Jiyuan
    Liu, Jingcheng
    Shi, Long
    [J]. SOLAR ENERGY, 2021, 225 : 33 - 43
  • [5] Experimental and numerical analysis of a naturally ventilated double-skin facade
    Souza, L. C. O.
    Souza, H. A.
    Rodrigues, E. F.
    [J]. ENERGY AND BUILDINGS, 2018, 165 : 328 - 339
  • [6] Ventilation performance of a naturally ventilated double-skin facade in buildings
    Tao, Yao
    Zhang, Haihua
    Zhang, Lili
    Zhang, Guomin
    Tu, Jiyuan
    Shi, Long
    [J]. RENEWABLE ENERGY, 2021, 167 : 184 - 198
  • [7] Modeling ventilation in naturally ventilated double-skin facade with a venetian blind
    Zeng, Zhen
    Li, Xiaofeng
    Li, Cheng
    Zhu, Yingxin
    [J]. BUILDING AND ENVIRONMENT, 2012, 57 : 1 - 6
  • [8] Coupling TRNSYS 17 and CONTAM: simulation of a naturally ventilated double-skin facade
    Khalifa, Ines
    Ernez, Leila Gharbi
    Znouda, Essia
    Bouden, Chiheb
    [J]. ADVANCES IN BUILDING ENERGY RESEARCH, 2015, 9 (02) : 293 - 304
  • [9] Energy efficiency of double-skin facade in office buildings of Shanghai
    Sun, Lu
    Jones, Phil J.
    Alexander, Don K.
    [J]. FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1755 - 1762
  • [10] Application of compact silencers as a noise barrier to a naturally ventilated double-skin facade
    Lee, Jeehwan
    Chang, Jae D.
    Coffeen, Robert
    [J]. NOISE CONTROL ENGINEERING JOURNAL, 2021, 69 (03) : 220 - 228