Functional MR Imaging on an Open 1T MR Imaging System: Exploiting the Advantages of an Open MR Imaging System for Functional MR Imaging

被引:1
|
作者
van de Giessen, E. [1 ]
Groot, P. F. C. [2 ]
Booij, J. [1 ]
van den Brink, W. [3 ]
Veltman, D. J. [3 ]
Nederveen, A. J. [2 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Amsterdam Inst Addict Res, NL-1105 AZ Amsterdam, Netherlands
关键词
BOLD CONTRAST; MOTOR TASK; 1.0; T; FMRI; CORTEX; ECHO; EPI; VARIABILITY; DEPENDENCE; ACTIVATION;
D O I
10.3174/ajnr.A2383
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Open MR imaging scanners are designed for imaging of specific patient groups that cannot be routinely scanned with conventional MR imaging scanners (eg, patients with obesity and claustrophobia). This study aims to determine whether BOLD sensitivity on an open 1T scanner is adequate for fMRI for diagnostic and research purposes by directly comparing fMRI results with a standard 3T MR imaging scanner The optimal TE was also determined. MATERIALS AND METHODS: Twelve healthy adults were scanned by using both an open 1T scanner and a standard 3T scanner. Gradient-echo echo-planar images were acquired for all subjects while performing motor and affective paradigms, each at 5 different TEs per scanner (range, 40-80 ms at open 1T; 20-40 ms at 3T). To compare BOLD sensitivity between scanners and TEs, we determined maximum statistical t scores per TE for all relevant brain areas (motor cortex, visual cortex, amygdala, and OFC) for individual subjects and group analyses. Additionally, T2* values were determined per scanner for the relevant brain areas. RESULTS: Maximum t scores were significantly lower in the relevant brain areas on the open 1T compared with the 3T for single subjects but not for group analyses. The optimal TE for fMRI on an open 1T MR imaging system was found to be approximately 70 ms. CONCLUSIONS: Although for single-subject studies as used in diagnostics, 31 was found to be superior, fMRI on an open 1T MR imaging scanner is suitable for research designed to analyze data at a group level.
引用
收藏
页码:903 / 907
页数:5
相关论文
共 50 条
  • [1] MR functional imaging
    Parrish, T
    MEDICAL PHYSICS, 2003, 30 (06) : 1413 - 1413
  • [2] MR imaging of the heart: functional imaging
    P. Croisille
    D. Revel
    European Radiology, 2000, 10 : 7 - 11
  • [3] MR imaging of the heart: functional imaging
    Croisille, P
    Revel, D
    EUROPEAN RADIOLOGY, 2000, 10 (01) : 7 - 11
  • [4] MR imaging, MR angiography and functional MR imaging in complex diagnostic of renovascular hypertension
    Sergienko, I.
    Belichenko, O.
    Guryakov, S.
    Sharia, M.
    JOURNAL OF HYPERTENSION, 2006, 24 : S161 - S162
  • [5] MR imaging monitoring microwave-induced tissue coagulation with a clinical MR imaging open system
    Ma, X
    Hatta, S
    Nagase, T
    Hareyama, N
    Tsukamoto, T
    RADIOLOGY, 1997, 205 : 1563 - 1563
  • [6] Functional MR Imaging of the Uterus
    Nakai, Asako
    Koyama, Takashi
    Fujimoto, Koji
    Togashi, Kaori
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2008, 16 (04) : 673 - +
  • [7] Functional MR Imaging of the Abdomen
    Sandrasegaran, Kumar
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2014, 52 (04) : 883 - +
  • [8] Functional MR imaging and oligodendrogliomas
    Dutertre, G
    Levêque, C
    Delmas, JM
    Cordoliani, YS
    Nioche, C
    NEUROCHIRURGIE, 2005, 51 (3-4) : 323 - 328
  • [9] Auditory functional MR imaging
    Bernal, B
    Altman, NR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (04) : 1009 - 1015
  • [10] Functional cardiac MR imaging
    Peters, DC
    Epstein, FH
    McVeigh, ER
    MEDICAL PHYSICS, 2000, 538 : 107 - 111