Magnetic Resonance Elastography of Liver: Influence of Intravenous Gadolinium Administration on Measured Liver Stiffness

被引:13
|
作者
Hallinan, James Thomas Patrick Decourcy [1 ]
Alsaif, Hind Saif [1 ,2 ]
Wee, Aileen [3 ]
Venkatesh, Sudhakar Kundapur [4 ]
机构
[1] Natl Univ Hlth Syst, Diagnost Imaging, Singapore, Singapore
[2] Dammam Univ, Coll Med, King Fahd Hosp Univ, Radiol, Al Khobar, Saudi Arabia
[3] Natl Univ Hlth Syst, Dept Pathol, Singapore, Singapore
[4] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
来源
ABDOMINAL IMAGING | 2015年 / 40卷 / 04期
关键词
Magnetic resonance elastography; Liver fibrosis; Intravenous Gd-DTPA; Liver stiffness; CHRONIC HEPATITIS-C; CLINICAL-APPLICATIONS; MR ELASTOGRAPHY; GADOXETIC ACID; FIBROSIS; DISEASE; ELASTICITY; IMAGES;
D O I
10.1007/s00261-014-0275-x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
To evaluate the effect of intravenous gadolinium-diethylenetriamine penta-acetic acid (Gd-DTPA) on estimation of liver stiffness using magnetic resonance elastography (MRE) for detection of liver fibrosis. Liver MRI with MRE was performed in 210 subjects on a single 1.5 Tesla clinical MRI scanner. Liver MRE was performed before intravenous Gd-DTPA injection (NC-MRE) and 5 minutes post injection (PC-MRE) using a modified phase-contrast gradient-echo sequence (TR/TE=100/27ms, FOV=30-46cm, 4x10mm slices, gap 5mm) which automatically generated stiffness maps. Two readers' blinded to clinical details independently performed liver stiffness measurements (LSM) by drawing 2 or more regions of interest (ROI) on the stiffness maps on each of the four slices of NC-MRE and PC-MRE obtained for each patient. The mean LSM in kilopascals (kPa) for NC-MRE and PC-MRE was calculated. The correlation between NC-MRE and PC-MRE LSM was evaluated with a paired t test and Pearson's correlation analysis, and the inter-observer correlation was evaluated using intra class coefficient (ICC) analysis. A receiver operating curve analysis (ROC) was performed to compare accuracies for detection and staging of liver fibrosis in a subgroup of 72 subjects with histological confirmation of liver fibrosis. There was an excellent correlation between NC-MRE and PC-MRE LSM (R-2=0.98, p < 0.001) with no significant differences. The interobserver agreement was also excellent (ICC, 0.94-0.99). There were no significant differences in the cut-off LSM value/accuracy/sensitivity/specificity for detection of significant liver fibrosis with NC-MRE and PC-MRE (2.98kPa/98.5%/100%/88%, p < 0.001 and 3.1kPa/98.2%/98%/88%, p < 0.001 respectively). Intravenous Gd-DTPA had no significant influence on LSM with MRE and does not significantly affect the diagnostic performance of MRE for fibrosis detection.
引用
收藏
页码:783 / 788
页数:6
相关论文
共 50 条
  • [1] Magnetic Resonance Elastography of Liver: Influence of Intravenous Gadolinium Administration on Measured Liver Stiffness
    James Thomas Patrick Decourcy Hallinan
    Hind Saif Alsaif
    Aileen Wee
    Sudhakar Kundapur Venkatesh
    Abdominal Imaging, 2015, 40 : 783 - 788
  • [2] Influence of Intravenous Gadolinium on Estimation of Liver Stiffness with Magnetic Resonance Elastography for Evaluation of Liver Fibrosis
    Venkatesh, S.
    Teo, L.
    Ang, B.
    Lim, S.
    Wee, A.
    Ehman, R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [3] LIVER STIFFNESS ON MAGNETIC RESONANCE ELASTOGRAPHY AND LIVER-RELATED OUTCOMES
    Ajmera, Veeral H.
    Nguyen, Khang
    Tamaki, Nobuharu
    Bettencourt, Ricki
    Loomba, Rohit
    HEPATOLOGY, 2021, 74 : 51A - 51A
  • [4] The role of magnetic resonance elastography in liver stiffness evaluation
    Mannelli, Lorenzo
    Monti, Serena
    Ogurtsov, Pavel
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2019, 129 (05): : 301 - 302
  • [5] Automated liver stiffness measurements with magnetic resonance elastography
    Dzyubak, Bogdan
    Glaser, Kevin
    Yin, Meng
    Talwalkar, Jayant
    Chen, Jun
    Manduca, Armando
    Ehman, Richard L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (02) : 371 - 379
  • [6] Liver stiffness measured by transient elastography: the influence of biochemical activity
    Coco, B.
    Oliveri, F.
    Colombatto, P.
    Ciccorossi, P.
    Sacco, R.
    Bonino, F.
    Brunetto, M. R.
    JOURNAL OF CLINICAL VIROLOGY, 2006, 36 : S172 - S172
  • [7] Liver stiffness measured by transient elastography: The influence of biochemical activity
    Coco, B.
    Oliveri, E.
    Colombatto, P.
    Ciccorossi, R.
    Sacco, R.
    Bonino, F.
    Brunetto, M. R.
    JOURNAL OF HEPATOLOGY, 2006, 44 : S196 - S196
  • [8] CHANGES IN LIVER STIFFNESS MEASURED BY MAGNETIC RESONANCE ELASTOGRAPHY ARE ASSOCIATED WITH OUTCOMES IN PRIMARY SCLEROSING CHOLANGITIS
    Eaton, John E.
    Sen, Aditi
    Hoodeshenas, Safa
    Schleck, Cathy
    Harmsen, William S.
    Gores, Gregory J.
    LaRusso, Nicholas F.
    Gossard, Andrea A.
    Lazaridis, Konstantinos N.
    Venkatesh, Sudhakar K.
    HEPATOLOGY, 2019, 70 : 766A - 766A
  • [9] Stiffness of liver-mimicking phantom for Magnetic Resonance Elastography
    Rojas, Guadalupe Sagaon
    Dies, Pilar
    Tobon, Silvia Hidalgo
    XV MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2019, 2090
  • [10] Magnetic Resonance Elastography Measured Shear Stiffness as a Biomarker of Fibrosis in Pediatric Nonalcoholic Fatty Liver Disease
    Schwimmer, Jeffrey B.
    Behling, Cynthia
    Angeles, Jorge Eduardo
    Paiz, Melissa
    Durelle, Janis
    Africa, Jonathan
    Newton, Kimberly P.
    Brunt, Elizabeth M.
    Lavine, Joel E.
    Abrams, Stephanie H.
    Masand, Prakash
    Krishnamurthy, Rajesh
    Wong, Kelvin
    Ehman, Richard L.
    Yin, Meng
    Glaser, Kevin J.
    Dzyubak, Bogdan
    Wolfson, Tanya
    Gamst, Anthony C.
    Hooker, Jonathan
    Haufe, William
    Schlein, Alexandra
    Hamilton, Gavin
    Middleton, Michael S.
    Sirlin, Claude B.
    HEPATOLOGY, 2017, 66 (05) : 1474 - 1485