The Security Analysis of Transpedicular Screw Fixation in the Lower Cervical Spine and a Case Report

被引:12
|
作者
Huang, Dongsheng [2 ]
Du, Kaili [2 ]
Zeng, Shixing [3 ]
Gao, Wenjie [2 ]
Huang, Lingzhi [2 ]
Su, Peiqiang [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Orthoped, Guangzhou 510275, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Affiliated Hosp 2, Dept Orthoped, Guangzhou 510275, Guangdong, Peoples R China
[3] Guangdong Prov Peoples Hosp, Dept Orthoped, Guangzhou, Guangdong, Peoples R China
关键词
cervical transpedicular screw fixation; cervical pedicle; vertebral artery; cervical spinal cord; PLACEMENT; INSERTION; ACCURACY; FEASIBILITY;
D O I
10.1097/BRS.0b013e31821a5240
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. This study evaluated the anatomical parameters of the lower cervical spine by imaging methods and reported a case. Objective. To explain low neurovascular injury rate and provide some suggestions in cervical transpedicular screw fixation (CTSF). Summary of Background Data. Because of anatomical complexity and possible severe complications, application of CTSF was limited. However, recent studies have indicated that although cervical pedicular screw perforations may happen, severe complications seldom occur. Methods. In 20 patients, several anatomical parameters were obtained on computed tomographic angiography (CTA) images of C3-C6, including the inner diameter of vertebral artery (d), the maximal width (A) and height (B) of the transverse foramen, the shortest distance between vertebral artery and cervical pedicle (h), and the angle between the longitudinal axis of pedicle and the hypothetical screw that just touches the vertebral artery (largest safe angle, LSA). Another 35 patients were chosen to measure the shortest distance between cervical pedicle and cervical spinal cord (H) and the angle between the longitudinal axis of pedicle and the hypothetical screw that just touches the cervical spinal cord (smallest angle, SA) on magnetic resonance imaging (MRI) of C4-C7. Results. Between the left and the right sides, there was no statistically significant difference for d, A, B, h, and LSA at C3-C6 or H and SA at C4-C7. d, h, and H were, respectively, 3.97 +/- 0.65 mm, 0.89 +/- 0.44 mm, and 6.56 +/- 2.10 mm, and there was no statistically significant difference among C3-C6 for d and h or among C4-C7 for H. LSA at C6 was larger than that at C3, C4, and C5; it increased from C5 to C7. Conclusion. There was an "escaping space" for the vertebral artery and spinal cord. CTSF in the superior part of pedicle was relatively safer from accidental perforation of the vertebral artery than CTSF in the inferior part, and in C6 and C7, CTSF was safer from this injury than in C3, C4, and C5.
引用
收藏
页码:E1702 / E1708
页数:7
相关论文
共 50 条
  • [1] Complications of transpedicular screw fixation in the cervical spine
    E. Kast
    K. Mohr
    H.-P. Richter
    W. Börm
    [J]. European Spine Journal, 2006, 15 : 327 - 334
  • [2] Complications of transpedicular screw fixation in the cervical spine
    Kast, E
    Mohr, K
    Richter, HP
    Börm, W
    [J]. EUROPEAN SPINE JOURNAL, 2006, 15 (03) : 327 - 334
  • [3] Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine
    Kothe, R
    Rüther, W
    Schneider, E
    Linke, B
    [J]. SPINE, 2004, 29 (17) : 1869 - 1875
  • [4] The anatomic variability of human cervical pedicles: considerations for transpedicular screw fixation in the middle and lower cervical spine
    E. K. Shin
    M. M. Panjabi
    N. C. Chen
    J.-L. Wang
    [J]. European Spine Journal, 2000, 9 : 61 - 66
  • [5] The anatomic variability of human cervical pedicles: considerations for transpedicular screw fixation in the middle and lower cervical spine
    Shin, EK
    Panjabi, MM
    Chen, NC
    Wang, JL
    [J]. EUROPEAN SPINE JOURNAL, 2000, 9 (01) : 61 - 66
  • [6] Morphological character of cervical spine for anterior transpedicular screw fixation
    Zhou, Rong-Ping
    Jiang, Jian
    Zhan, Zi-Chun
    Zhou, Yang
    Liu, Zhi-Li
    Yin, Qing-Shui
    [J]. INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (06) : 553 - 558
  • [7] Morphological character of cervical spine for anterior transpedicular screw fixation
    Rong-Ping Zhou
    Jian Jiang
    Zi-Chun Zhan
    Yang Zhou
    Zhi-Li Liu
    Qing-Shui Yin
    [J]. Indian Journal of Orthopaedics, 2013, 47 : 553 - 558
  • [8] BIOMECHANICAL ANALYSIS OF CERVICAL STABILIZATION SYSTEMS - AN ASSESSMENT OF TRANSPEDICULAR SCREW FIXATION IN THE CERVICAL-SPINE
    KOTANI, Y
    CUNNINGHAM, BW
    ABUMI, K
    MCAFEE, PC
    [J]. SPINE, 1994, 19 (22) : 2529 - 2539
  • [9] TRANSPEDICULAR SCREW FIXATION FOR TRAUMATIC LESIONS OF THE MIDDLE AND LOWER CERVICAL-SPINE - DESCRIPTION OF THE TECHNIQUES AND PRELIMINARY-REPORT
    ABUMI, K
    ITOH, H
    TANEICHI, H
    KANEDA, K
    [J]. JOURNAL OF SPINAL DISORDERS, 1994, 7 (01): : 19 - 28
  • [10] Progress of the Anterior Transpedicular Screw in Lower Cervical Spine: A Review
    Zhang, Yuan-Wei
    Zeng, Ting
    Gao, Wen-Cheng
    Xiao, Xin
    Xiao, Yan
    Chen, Xi
    Zhang, Su-Li
    Deng, Liang
    [J]. MEDICAL SCIENCE MONITOR, 2019, 25 : 6281 - 6290