Studies on the Influence of Copper and Insulation Paper on the Accelerated Thermal Ageing of Some Insulating Fluids

被引:0
|
作者
Lingvay, Iosif [1 ]
Oprina, Gabriela [1 ]
Stanoi, Valerica [2 ]
Pica, Alexandra [3 ]
Ungureanu, Livia Carmen [2 ]
Serban, Florentina [3 ]
机构
[1] Natl Inst Res & Dev Elect Engn INCDIE ICPE CA Buc, 313 Splaiul Unirii, Bucharest 030138, Romania
[2] Natl Inst Res Dev & Testing Elect Engn, 118A Decebal Blvd, Craiova 200746, Romania
[3] Res Inst Adv Coatings, 313 Splaiul Unirii, Bucharest 030138, Romania
来源
REVISTA DE CHIMIE | 2017年 / 68卷 / 11期
关键词
transformer oil; mineral oil; ester oil; thermal ageing; insulation paper;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The behaviour of some insulating fluids in contact with copper foil and/or insulation paper under thermal stress (110 +/- 3 degrees C for 1000 hours), in a closed system (the access of atmospheric oxygen being limited), has been studied by determining the changes in viscosity and concentration of CO2 and CO. The experimental data revealed that, following the applied heat treatment, the change in viscosity of the esters-based insulating fluids (both synthetic and vegetable) is approximately 7 times lower than in the case of the investigated mineral oils. It has also been found that, following the thermal ageing, the gas content of the mineral oils is substantially higher than in the esters-based oils (8 times higher for CO2 and 4 times higher for CO, respectively). The experimental results indicate superior values for the thermal stability and compatibility with the insulation paper of ester-based insulating fluids.
引用
收藏
页码:2551 / 2555
页数:5
相关论文
共 50 条
  • [1] Thermal Ageing of Some Insulating Fluids in Contact with Insulation Paper and Copper
    Lingvay, Iosif
    Oprina, Gabriela
    Ungureanu, Livia Carmen
    Pica, Alexandra
    Stanoi, Valerica
    REVISTA DE CHIMIE, 2017, 68 (12): : 2881 - 2885
  • [2] Thermo-chemical stability and compatibility with insulation paper of some insulating fluids
    Stabilitatea termochimică și compatibilitatea cu hârtia electroizolantă a unor fluide electroizolante
    Lingvay, Iosif (coroziune@icpe-ca.ro), 1600, Editura ELECTRA (65):
  • [3] Analysis of Ageing Characteristics of Solid Insulation in Mixed Insulating Fluids
    Raymon, A.
    Sidthik, A. Sheik
    Rajan, V. Kalai
    Kumar, A. Senthil
    Lakshmanan, G.
    2014 ANNUAL INTERNATIONAL CONFERENCE ON EMERGING RESEARCH AREAS: MAGNETICS, MACHINES AND DRIVES (AICERA/ICMMD), 2014,
  • [4] Influence of thermal ageing on dielectric response of oil-paper insulation
    Gielniak, J.
    Graczkowski, A.
    Gubanski, S.
    Moranda, H.
    Moscicka-Grzesiak, H.
    Walczak, K.
    MATERIALS SCIENCE-POLAND, 2009, 27 (04): : 1199 - 1205
  • [5] Neural networks in prediction of accelerated thermal ageing effect on oil/paper insulation tensile strength
    Mokhnache, L
    Verma, P
    Boubakeur, A
    PROCEEDINGS OF THE 2004 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2004, : 575 - 577
  • [6] Influence of Proportion of Vegetable Insulating Oil and Mineral Insulating Oil on Thermal Aging of Oil-Paper Insulation
    Wang, Baimei
    Li, Jian
    Xiang, Junru
    Du, Bin
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 180 - 183
  • [7] Thermally Accelerated Aging of Insulation Paper for Transformers with Different Insulating Liquids
    Muenster, Tobias
    Werle, Peter
    Haemel, Kai
    Preusel, Joerg
    ENERGIES, 2021, 14 (11)
  • [8] The Influence of Accelerated Ageing on the Oil Impregnated Paper
    Lison, Lukas
    Kolcunova, Iraida
    Pavlik, Marek
    PROCEEDINGS OF THE 2015 16TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2015, : 743 - 747
  • [9] Some studies on the dielectric strength of insulating fluids
    Charlton, EE
    Cooper, FS
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1939, 41 : 114 - 120
  • [10] ASSESSMENT OF LONG THERMAL AGEING ON THE OIL-PAPER INSULATION
    Kolcunova, Iraida
    Pavlik, Marek
    Lison, Lukas
    ADVANCES IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2016, 14 (05) : 506 - 511