Thermo-hydraulic coupled analysis of meshed district heating networks based on improved breadth first search method

被引:18
|
作者
Wang, Yaran [1 ,2 ]
Shi, Kaiyu [1 ,2 ]
Zheng, Xuejing [1 ,2 ]
You, Shijun [1 ,2 ]
Zhang, Huan [1 ,2 ]
Zhu, Chengzhi [3 ]
Li, Liang [3 ]
Wei, Shen [4 ]
Ding, Chao [1 ]
Wang, Na [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300350, Peoples R China
[2] Tianjin Key Lab Biomass Wastes Utilizat, Tianjin 300350, Peoples R China
[3] Shijiazhuang Huadian Heating Grp Co Ltd, Shijiazhuang 050041, Hebei, Peoples R China
[4] Univ Coll London UCL, Bartlett Sch Construct & Project Management, 1-19 Torrington Pl, London WC1E 7HB, England
基金
国家重点研发计划;
关键词
Meshed district heating network; Topology sorting; Improved breadth first search method; Thermo-hydraulic coupled model; Hydraulic computation frequency; Thermal dynamics; HYDRAULIC PERFORMANCE; OPTIMAL OPERATION; THERMAL INERTIA; PIPE MODEL; SYSTEM; OPTIMIZATION; SIMULATION; POWER; INTEGRATION; DYNAMICS;
D O I
10.1016/j.energy.2020.117950
中图分类号
O414.1 [热力学];
学科分类号
摘要
Efficient numerical simulation of thermo-hydraulic coupled conditions is critical for analysis and control of DH network. However, for most of meshed DH network, the flow directions of its pipelines may change, which will lead to difficulties in effective numerical calculation of the thermo-hydraulic conditions. This paper established an efficient thermo-hydraulic coupled calculation method, which utilizes the topology sorting algorithm to obtain the calculation sequence of all pipelines during numerical thermal transient calculation, according to the flow directions and flow rates of all pipelines. The flow directions and flow rates are solved by hydraulic condition calculation at each time step. The proposed method is applied to a real meshed DH network for thermal dynamic simulation. Independence analysis of hydraulic computation frequency is conducted, and convergences of the simulated temperature variations are observed when hydraulic computation frequency gets larger. Thermal dynamics of the meshed DH network are analyzed with 10-min hydraulic computation interval. Results show that the temperature decay and time delay can be up to 2.7 degrees C and 210 min for the simulated network. Thermal dynamic characteristics of supply temperature waves are various considering the distance from heat source, fluctuations of outdoor temperature and the variations of substation flow rate. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 16 条
  • [1] Thermo-hydraulic coupled analysis of meshed district heating networks based on improved breadth first search method
    Wang, Yaran
    Shi, Kaiyu
    Zheng, Xuejing
    You, Shijun
    Zhang, Huan
    Zhu, Chengzhi
    Li, Liang
    Wei, Shen
    Ding, Chao
    Wang, Na
    Energy, 2021, 205
  • [2] Thermo-hydraulic coupled analysis of long-distance district heating systems based on a fully-dynamic model
    Wang, Yaran
    Wang, Xiaoxin
    Zheng, Lijun
    Gao, Xinyong
    Wang, Zhe
    You, Shijun
    Zhang, Huan
    Wei, Shen
    APPLIED THERMAL ENGINEERING, 2023, 222
  • [3] Thermo-hydraulic coupled simulation and analysis of a real large-scale complex district heating network in Tianjin
    Zheng, Xuejing
    Sun, Qihang
    Wang, Yaran
    Zheng, Lijun
    Gao, Xinyong
    You, Shijun
    Zhang, Huan
    Shi, Kaiyu
    ENERGY, 2021, 236
  • [4] Stability Analysis and Mitigation of Thermo-Hydraulic Oscillations in Multi-Supplier District Heating Systems
    Friedrich, Pascal
    Kuroptev, Kirill
    Huynh, Thanh
    Niessen, Stefan
    ENERGIES, 2025, 18 (05)
  • [5] Dynamic equation-based thermo-hydraulic pipe model for district heating and cooling systems
    van der Heijde, B.
    Fuchs, M.
    Tugores, C. Ribas
    Schweiger, G.
    Sartor, K.
    Basciotti, D.
    Mueller, D.
    Nytsch-Geusen, C.
    Wetter, M.
    Helsen, L.
    ENERGY CONVERSION AND MANAGEMENT, 2017, 151 : 158 - 169
  • [6] Effects of fouling on performance of retrofitted heat exchanger networks: A thermo-hydraulic based analysis
    Coletti, Francesco
    Macchietto, Sandro
    Polley, Graham T.
    COMPUTERS & CHEMICAL ENGINEERING, 2011, 35 (05) : 907 - 917
  • [7] Effects of fouling on performance of retrofitted heat exchanger networks; a thermo-hydraulic based analysis
    Coletti, Francesco
    Macchietto, Sandro
    Polley, Graham T.
    20TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2010, 28 : 19 - 24
  • [8] Thermo-hydraulic and structural analysis for finger-based concept of ITER blanket first wall
    Kim, Byoung-Yoon
    Ahn, Hee-Jae
    FUSION ENGINEERING AND DESIGN, 2011, 86 (9-11) : 1997 - 2002
  • [9] Pipe Hydraulic Resistances Identification of District Heating Networks Based on Matrix Analysis
    Liu, Yongxin
    Wang, Peng
    Luo, Peng
    ENERGIES, 2020, 13 (11)
  • [10] An Improved Breadth-First Search Method Based on Information Interaction Applied for Power Network Topology Analysis
    Bian, Haihong
    Guo, Zhengyang
    Wang, Ximeng
    Zhou, Chengang
    Bing, Shengwei
    Zhang, Zhiyuan
    Sun, Qiuye
    Mathematical Problems in Engineering, 2023, 2023