Clinical and laboratory evaluation of a new specific ELISA for intact proinsulin

被引:0
|
作者
Pfützner, A
Pfützner, AH
Kann, PH
Stute, R
Löbig, M
Yang, JW
Mistry, J
Forst, T
机构
[1] Inst Klin Forsch & Entwicklung, D-55116 Mainz, Germany
[2] Univ Appl Sci, Rheinbach, Germany
[3] Univ Hosp Marburg, Dept Endocrinol & Diabet, Marburg, Germany
[4] Labor Dr Latza, St Ingbert, Germany
[5] Linco Res, St Charles, MO USA
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Intact proinsulin is a marker for pancreatic beta-islet cell secretion status, and elevated levels indicate insulin resistance of type 2 diabetic patients with a high diagnostic specificity. Determination of intact proinsulin in fasting morning plasma samples can be used to establish and/or identify the optimal anti-diabetic treatment as well as to monitor a potential protective treatment effect on beta-islet cell dysfunction. For widespread use as a routine marker, simple and reliable assays must become available for measurement in clinical laboratories. This study was performed to evaluate a new ELISA method specific for intact proinsulin determination compared with a commercial chemiluminescence test. Intra-assay imprecision was determined to be 2.4 - 5.5% (inter-assay: 3.2 - 4.3%). A sample cohort derived from non-diabetic healthy subjects (66 female, 29 male, age (median, range): 37 (19-77) years) was used to calculate a reference range for non-diabetic individuals of 1.8 - 11.0 pmol/l. The comparison of samples obtained from 7 diabetic patients (2 female, 5 male, age: 66 (44-72) years) from oral glucose tolerance tests resulted in an excellent correlation between the ELISA and the chemiluminescence assay (r = 0.989; p < 0.001). A sample stability investigation with different sample specimens revealed that intact proinsulin is stable for two days at room temperature in EDTA whole blood and heparin whole blood tubes without centrifugation, while serum samples should be centrifuged immediately and frozen to retain intact proinsulin concentrations. As EDTA whole blood is the routine sample specimen for determination of HbA1c, a marker frequently measured in diabetic patients, this finding underlines the practicability of analyzing intact proinsulin from the same blood specimen. In conclusion our study revealed that the new ELISA shows excellent agreement with the commonly used chemiluminescence immunoassay. The ELISA can easily be introduced into routine laboratories and does not require any further specific instrumentation. Our additional finding that intact proinsulin is stable in EDTA whole blood samples, which can be obtained from the routine sample for HbA1c measurement, is increasing the probability of the acceptance of this marker for routine assessment of R-cell dysfunction and insulin resistance in type 2 diabetes.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 50 条
  • [1] Clinical and laboratory evaluation of a new specific ELISA for intact proinsulin summary
    Siebenhaar, R.
    Weise, A.
    Safinowski, M.
    Reisinger, K.
    Musholt, P. B.
    Reimer, T.
    Forst, T.
    Pfuetzner, A.
    DIABETES STOFFWECHSEL UND HERZ, 2008, 17 (04): : 275 - 281
  • [2] Clinical and laboratory evaluation of specific chemiluminescence assays for intact and total proinsulin
    Pfützner, A
    Kunt, T
    Langenfeld, M
    Löbig, M
    Knesovic, M
    Forst, T
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (09) : 1234 - 1238
  • [3] Evaluation of a New Specific Rapid Test for Intact Proinsulin
    Pfuetzner, A.
    Pfuetzner, A. H.
    Kann, R. H.
    Burgard, G.
    DIABETES STOFFWECHSEL UND HERZ, 2016, 25 (04): : 209 - 214
  • [4] FIRST ASSAY SPECIFIC FOR INTACT HUMAN PROINSULIN
    DINESEN, B
    HOUSSA, P
    DEBERG, M
    SODOYEZ, JC
    SODOYEZGOFFAUX, F
    DIABETOLOGIA, 1994, 37 : A103 - A103
  • [5] Determination of intact proinsulin in human serum using the DRG ELISA.
    Fiedler, R
    Pulzer, F
    Keller, E
    Kratzsch, J
    CLINICAL CHEMISTRY, 1996, 42 (06) : 116 - 116
  • [6] Development of a novel immunoassay specific for mouse intact proinsulin
    Imai, Sunao
    Takahashi, Tatsuya
    Naito, Shoichi
    Yamauchi, Akira
    Okada, Chihiro
    Notsu, Yoshihide
    Sakikawa, Ikue
    Hatanaka, Michiyoshi
    Iwasaki, Takanori
    Morita, Atsushi
    Fujii, Ikuo
    Yamane, Shoji
    ANALYTICAL BIOCHEMISTRY, 2015, 484 : 91 - 98
  • [7] EVALUATION OF A NEW ELISA FOR SPECIFIC IGE - THE STALLERZYM
    DUC, J
    PEITREQUIN, R
    PECOUD, A
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1987, 79 (01) : 224 - 224
  • [8] Development and laboratory evaluation of a new recombinant ELISA for the serodiagnosis of Lyme disease
    Hunfeld, KP
    Ernst, M
    Zachary, P
    Jaulhac, B
    Sonneborn, HH
    Brade, V
    WIENER KLINISCHE WOCHENSCHRIFT, 2002, 114 (13-14) : 580 - 585
  • [9] Evaluation two enzyme amplified immunoassays detecting total and intact proinsulin
    Dark, C
    Lewrey, D
    Willers, EL
    Wisdom, NM
    Ashworth, L
    Walker, N
    Humphriss, D
    Bates, DL
    DIABETOLOGIA, 1996, 39 : 811 - 811
  • [10] Hyperinsulinemia in nondiabetic Asian subjects using specific assays for insulin, intact proinsulin, and des-31,32-proinsulin
    Nagi, DK
    Ali, VM
    Walji, S
    Jain, SK
    Yudkin, JS
    DIABETES CARE, 1996, 19 (01) : 39 - 42