Ambulatory monitoring of blood pressure (AMBP) in patients with primary hyperparathyroidism

被引:37
|
作者
Letizia, C
Ferrari, P
Cotesta, D
Caliumi, C
Cianci, R
Cerci, S
Petramala, L
Celi, M
Minisola, S
D'Erasmo, E
Mazzuoli, GF
机构
[1] Univ Roma La Sapienza, Dept Clin Sci, Rome, Italy
[2] Univ Roma La Sapienza, Day Hosp Internal Med & Arterial Hypertens, Rome, Italy
关键词
blood pressure; ambulatory monitoring blood pressure; essential hypertension; primary hyperparathyroidism; dipper and non-dipper;
D O I
10.1038/sj.jhh.1001907
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The purpose of our study was to evaluate the behaviour of blood pressure (BP) by ambulatory monitoring of blood pressure (AMBP) in 53 patients with primary hyperparathyroidism (dPHPT) compared to 100 essential hypertensive (EH) and 31 healthy subjects (HS). The correlations between calcium-phosphorus metabolism and haemodynamic parameters in all groups are included in the study. AMBP was performed using the oscillometric technique (Space-Labs, 90207, Redmond, WA, USA) and the following AMBP parameters were evaluated: average day time systolic (S) and diastolic (D) blood pressure (BP) and heart rate (HR) (when awake), average night time SBP, DBP and HR (when asleep) and average 24-h-SBP, DBP and HR. The definition of 'dipper' or 'non-dipper' subjects was established if night time SBP and DBP fall was >10% and <10%, respectively. In total, 25 PHPT patients (47.2%) were hypertensive (HT-PHPT) and 28 PHPT (52.8%) were normotensive (NT-PHPT). Mean 24-h-SBP and DBP obtained by AMBP was higher in HT-PHPT (P<0.05) and EH (P<0.05) than in NT-PHPT and HS. The multiple linear regression has shown that in PHPT-HT patients ionized calcium is an independent factor for the rise of 24-h-DBP values (r: 0.497; P<0.05) and daytime DBP values (r: 0.497; P<0.05). In 56% of HT-PHPT patients there is an absence of physiological BP nocturnal fall ('non-dipper'), which is statistically significant (P<0.05) compared with 'non-dipper' EH patients (30%). In conclusion, in our study the prevalence of hypertension in PHPT was 47%. AMBP revealed that the 'non-dipping' pattern was much higher in HT-PHPT patients in respect to EH patients.
引用
收藏
页码:901 / 906
页数:6
相关论文
共 50 条
  • [1] Ambulatory monitoring of blood pressure (AMBP) in patients with primary hyperparathyroidism
    C Letizia
    P Ferrari
    D Cotesta
    C Caliumi
    R Cianci
    S Cerci
    L Petramala
    M Celi
    S Minisola
    E D'Erasmo
    G F Mazzuoli
    [J]. Journal of Human Hypertension, 2005, 19 : 901 - 906
  • [2] Ambulatory blood pressure monitoring (AMBP) in obese patients
    Lucas, J.
    Zamora, I
    Vitoria, I
    Dalmau, J.
    Bosca, J.
    [J]. PEDIATRIC NEPHROLOGY, 2011, 26 (08) : 1353 - 1354
  • [3] Ambulatory blood pressure monitoring (AMBP) in children with chronic kidney disease.
    Sanahuja, M. J.
    Lucas, J.
    Zamora, I
    Ortega, P.
    Agusti, S.
    [J]. PEDIATRIC NEPHROLOGY, 2011, 26 (08) : 1350 - 1350
  • [4] Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism
    Concistre, A.
    Grillo, A.
    La Torre, G.
    Carretta, R.
    Fabris, B.
    Petramala, L.
    Marinelli, C.
    Rebellato, A.
    Fallo, F.
    Letizia, C.
    [J]. ENDOCRINE, 2018, 60 (01) : 129 - 137
  • [5] Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism
    A. Concistrè
    A. Grillo
    G. La Torre
    R. Carretta
    B. Fabris
    L. Petramala
    C. Marinelli
    A. Rebellato
    F. Fallo
    C. Letizia
    [J]. Endocrine, 2018, 60 : 129 - 137
  • [6] AMBULATORY BLOOD PRESSURE MONITORING-DERIVED SHORT-TERM BLOOD PRESSURE VARIABILITY IN PRIMARY HYPERPARATHYROIDISM
    Concistre, A.
    Grillo, A.
    Carretta, R.
    Fabris, B.
    Petramala, L.
    Marinelli, C.
    Rebellato, A.
    Fallo, F.
    Letizia, C.
    [J]. JOURNAL OF HYPERTENSION, 2016, 34 : E269 - E269
  • [7] Blood pressure control with monitoring ambulatory blood pressure (AMBP), self-measured blood pressure at home (SMBP) and office blood pressure
    Gomez-Marcos, M. A.
    Garcia-Ortiz, L.
    Gonzalez Elena, L. J.
    Castano-Sanchez, Y.
    Rodriguez, J. I. Recio
    Parra-Sanchez, J.
    Garcia-Garcia, A.
    Cascon-Perez-Teijon, S.
    Gonzalez-Garcia, A.
    Herrero-Rodriguez, C.
    Sanchez-Salgado, B.
    Rodriguez Martin, C.
    Sanchez, C. Castano
    Jimenez, D. Munoz
    De Cabo-Laso, A.
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 : S292 - S292
  • [8] AMBULATORY BLOOD-PRESSURE (AMBP) MONITORING IN NORMOALBUMINURIC TYPE-1 (IDDME DIABETIC-PATIENTS
    RAPUANO, A
    PENNO, G
    RIZZO, L
    NANNIPIERI, M
    BANDINELLI, S
    PUCCI, L
    BERTACCA, A
    CARICATO, F
    NAVALESI, R
    [J]. DIABETOLOGIA, 1995, 38 : A212 - A212
  • [9] Ambulatory Blood Pressure Monitoring in Primary Care
    Wexler, Randy
    [J]. SOUTHERN MEDICAL JOURNAL, 2010, 103 (05) : 447 - 452
  • [10] 11.3 Ambulatory Monitoring of Blood Pressure (AMBP) in Young People with Obstructive Sleep Apnoea Syndrome (OSAS
    R. Muschera’
    M. D’avino
    G. Caruso
    E. Anastasio
    D. Caruso
    F. De Michele
    R. Muschera’
    [J]. High Blood Pressure & Cardiovascular Prevention, 2008, 15 (3) : 299 - 299