Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function

被引:18
|
作者
Daou, D
Vilain, D
Colin, P
Lebtahi, R
Fourme, T
Coaguila, C
Benada, A
Idy-Peretti, I
Slama, M
Le Guludec, D
机构
[1] Lariboisiere Univ Hosp, Dept Nucl Med, AP HP, F-75475 Paris, France
[2] Foch Hosp, Dept Nucl Med, Suresnes, France
[3] Beclere Univ Hosp, AP HP, Dept Cardiol, Clamart, France
[4] Hop Xavier Bichat, Dept Nucl Med, AP HP, Paris, France
关键词
left ventricular function; ECG-gated blood pool SPET; ECG-gated myocardial perfusion SPET; (TI)-T-201-gated SPET;
D O I
10.1007/s00259-003-1121-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Both electrocardiographically (ECG) gated blood pool SPET (GBPS) and ECG-gated myocardial perfusion SPET (GSPET) are currently used for the measurement of global systolic left ventricular (LV) function. In this study, we aimed to compare the value of GSPET and GBPS for this purpose. The population included 65 patients who underwent rest thallium-201 GSPET imaging at 15 min after Tl-201 injection followed by planar (planar(RNA)) and GBPS equilibrium radio-nuclide angiography immediately after 4-h redistribution myocardial perfusion SPET imaging. Thirty-five patients also underwent LV conventional contrast angiography (X-rays). LV ejection fraction (EF) and LV volume [end-diastolic (EDV) and end-systolic (ESV) volumes] were calculated with GBPS and GSPET and compared with the gold standard methods (planar(RNA) LVEF and X-ray based calculation of LV volume). For both LVEF and LV volume, the inter-observer variability was lower with GBPS than with GSPET. GBPS LVEF was higher than planar(RNA) (P<0.01) and GSPET LVEF (P<0.01). Planar(RNA) LVEF showed a slightly better correlation with GBPS LVEF than with GSPET LVER r=0.87 and r=0.83 respectively. GSPET LV volume was lower than that obtained using X-rays and GBPS (P<0.01 for both). LV volume calculated using X-rays showed a slightly better correlation with GBPS LV volume than with GSPET LV volume: r=0.88 and r=0.83 respectively. On stepwise regression analysis, the accuracy of GSPET for the measurement of LVEF and LV volume was correlated with a number of factors, including planar(RNA) LVEF, signal to noise ratio, LV volume calculated using X-rays, summed rest score and acquisition scan distance (i.e. the radius of rotation). The accuracy of GBPS for the measurement of LVEF and LV volume was correlated only with the signal level, the signal to noise ratio and the acquisition scan distance. Both GSPET and GBPS provide reliable estimation of global systolic LV function. The better reliability of GBPS and in particular its lower sensitivity to different variables as compared with GSPET favours its use when precise assessment of global systolic LV function is clinically indicated.
引用
收藏
页码:859 / +
页数:10
相关论文
共 50 条
  • [1] Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function
    Doumit Daou
    Didier Vilain
    Patrice Colin
    Rachida Lebtahi
    Thierry Fourme
    Carlos Coaguila
    Abdel Benada
    Ilana Idy-Peretti
    Michel Slama
    Dominique Le Guludec
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 859 - 867
  • [2] Assessment of left ventricular systolic and diastolic function based on the edge detection method with myocardial ECG-gated SPET
    Higuchi, T
    Nakajima, K
    Taki, J
    Kinuya, S
    Bunko, H
    Tonami, N
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (10): : 1512 - 1516
  • [3] Assessment of left ventricular systolic and diastolic function based on the edge detection method with myocardial ECG-gated SPET
    Takahiro Higuchi
    Kenichi Nakajima
    Junichi Taki
    Seigo Kinuya
    Hisashi Bunko
    Norihisa Tonami
    [J]. European Journal of Nuclear Medicine, 2001, 28 : 1512 - 1516
  • [4] A comparison and validation of blood-pool imaging and ECG-gated SPET myocardial perfusion imaging to assess left ventricular ejection fraction
    Xia, Wei
    Lv, Zhongwei
    Wang, Guoyu
    Cai, Haidong
    Ni, Jing
    Zhang, Yuna
    Ye, Beihong
    [J]. HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2010, 13 (03): : 241 - 245
  • [5] Left ventricular function at rest and during bicycle exercise in normal subjects:: Assessment by ECG-gated myocardial perfusion SPET with 99Tcm-tetrofosmin
    Kumita, S
    Cho, K
    Mizumura, S
    Kijima, T
    Nakajo, H
    Takahama, K
    Furukawa, K
    Kumazaki, T
    Sano, J
    Munakata, K
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (05) : 427 - 432
  • [6] Respiratory motion influence on ECG-gated SPET: a simulation study
    Bitarafan-Rajabi, Ahmad
    Rajabi, Hossein
    Rustgou, Feridoon
    Firoozabady, Hasan
    Yaghoobi, Nahid
    Malek, Hadi
    Moladoust, Hassan
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 2174 - 2177
  • [7] Assessment of ventricular function with ECG-gated multidetector CT
    Gilkeson, RC
    Malguria, N
    [J]. RADIOLOGY, 2001, 221 : 413 - 413
  • [8] Quantification of left ventricular regional functions using ECG-gated myocardial perfusion SPECT —validation of left ventricular systolic functions—
    Akira Yamamoto
    Tetsuo Hosoya
    Naoto Takahashi
    Shin-ichiro Iwahara
    Kazuo Munakata
    [J]. Annals of Nuclear Medicine, 2006, 20 : 449 - 456
  • [9] Reference values for left ventricular systolic synchrony according to phase analysis of ECG-gated myocardial perfusion SPECT
    Hamalainen, Hanna
    Hedman, Marja
    Laitinen, Tiina
    Hedman, Antti
    Kivela, Antti
    Laitinen, Tomi
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2018, 38 (01) : 38 - 45
  • [10] ESTIMATION OF LEFT-VENTRICULAR FUNCTION ON ECG-GATED TL-201 MYOCARDIAL PERFUSION IMAGES
    HURWITZ, GA
    DRIEDGER, AA
    DAIN, RP
    LAURIN, NR
    MACDONALD, AC
    JONES, DT
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 1989, 5 (07) : 343 - 351