Does monitoring of pre-/post-dialyzer pressure difference improve efficiency in intermittent hemodialysis?

被引:4
|
作者
Gabutti, L
Colucci, G
Martella, A
Schönholzer, C
Marone, C
机构
[1] Osped Carita, Dept Nephrol, CH-6600 Locarno, Switzerland
[2] Osped Reg Lugano, Dept Nephrol, Lugano, Switzerland
[3] Osped San Giovanni Bellinzona, Dept Internal Med, Bellinzona, Switzerland
关键词
pressure difference; dialyzer; intermittent hemodialysis; clotting; urea clearance; dialysis efficiency;
D O I
10.1159/000072548
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Continuous monitoring of pre-/post-dialyzer pressure difference (DeltaP) is widely used in continuous renal replacement therapies to monitor extracorporeal circuit function. The aim of this study was to verify whether DeltaP may help to identify chronic subclinical worsening of dialysis quality due to incomplete dialyzer clotting in intermittent hemodialysis. Methods: Nine chronic hemodialysis patients were enrolled in the study and dialyzed twice (high-flux polysulfone dialyzer) with DeltaP and urea-clearance monitoring: the first session with a standard anticoagulation and the second without. To verify whether a visible clotting of the dialyzer precedes or follows a significant DeltaP increase, we checked the dialyzers for the presence of red clots after a saline flush performed when a 50% increase in DeltaP was registered. Results: In the second dialysis session after a 50% increase in DeltaP (documented in 7/9 patients), all dialyzers, after saline flush, showed a visible fiber clotting but not a significant reduction (>15%) in urea clearance. In the majority of the patients (6/7), until a few minutes before complete occlusion of the extracorporeal circuit, the urea clearance did not change significantly (-8.9 +/- 12.7%). Conclusions:The usual check of the presence or absence of red clots in the dialyzer at the end of the dialysis session is enough, in the absence of red clots, to ensure that dialyzer efficiency is maintained during the whole treatment. Contrary to what is applied in CRRT, a continuous monitoring of AP during intermittent hemodialysis would not significantly help to unmask unnoticed inefficient hemodialysis sessions. Copyright (C) 2003 S. KargerAG, Basel.
引用
收藏
页码:294 / 300
页数:7
相关论文
共 15 条
  • [1] Pre- and post-pyeloplasty renal function: Does it improve?
    McAleer, I
    Kaplan, GW
    PEDIATRICS, 1998, 102 (03) : 837 - 837
  • [2] Does gender difference mitigate the cardioprotection by pre- and post-conditioning in the clinical practice?
    Lou, Baohui
    Zhou, Chenghui
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 251 : 14 - 14
  • [3] BLOOD PRESSURE MONITORING IN HEMODIALYSIS PATIENTS: ARE IMPRECISE THE MEASURING PRE- AND POSTDIALYSIS OR INTERDIALYTIC AMBULATORY BP?
    Estifan Kasabji, Jorge
    Sanchez Montero, Sylvia
    Martinez Rosero, Caterin
    Martelli Guerrero, Xhamy
    Romero Zaldumbide, Erica
    Lucas Alvarez, Cristina
    Sastre Lopez, Arancha
    Monfa Giux, Elena
    De Leon Gomez, Benjamin
    Prieto Velasco, Mario
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E102 - E103
  • [4] The association between ultrafiltration volume and difference of the pre- and post-dialysis hemoglobin levels in maintenance hemodialysis patients
    Moeddel, Michael
    SWISS MEDICAL WEEKLY, 2014, 144 : 32S - 32S
  • [5] Correlation between pre- and post-dialysis blood pressure levels in hemodialysis patients with intradialytic hypertension
    M. S. Rita de Cássia Mattos
    Helton P. Lemes
    Sebastião R. Ferreira-Filho
    International Urology and Nephrology, 2016, 48 : 2095 - 2099
  • [6] Correlation between pre- and post-dialysis blood pressure levels in hemodialysis patients with intradialytic hypertension
    Rita de Cassia Mattos, M. S.
    Lemes, Helton P.
    Ferreira-Filho, Sebastiao R.
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2016, 48 (12) : 2095 - 2099
  • [7] Intraoperative pre- and post-craniofacial reconstruction intracranial pressure (ICP) monitoring in children with craniosynostosis
    Yokote, Akiyoshi
    Aihara, Yasuo
    Eguchi, Seiichiro
    Okada, Yoshikazu
    CHILDS NERVOUS SYSTEM, 2013, 29 (08) : 1363 - 1367
  • [8] Blood Pressure Monitoring in the Biological Time Structures and in Pre-/Post-Surgery Seasonal Variations
    Lee, Mary S.
    Lee, John S.
    Halberg, Franz
    Lee, Jong Y.
    HYPERTENSION, 2013, 62 (03)
  • [9] Intraoperative pre- and post-craniofacial reconstruction intracranial pressure (ICP) monitoring in children with craniosynostosis
    Akiyoshi Yokote
    Yasuo Aihara
    Seiichiro Eguchi
    Yoshikazu Okada
    Child's Nervous System, 2013, 29 : 1363 - 1367
  • [10] MEAN OF PRE- AND POST-DIALYSIS SYSTOLIC BLOOD PRESSURE IS AN INDEPENDENT PREDICTOR OF HOME SYSTOLIC BLOOD PRESSURE IN HEMODIALYSIS PATIENTS
    Choi, Hye Min
    Na, Hyun-Jin
    Kim, Myung-Sung
    Oh, Dong-Jin
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30