Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants

被引:59
|
作者
Skjoldebrand, Charlotte [1 ]
Tipper, Joanne L. [2 ]
Hatto, Peter [3 ]
Bryant, Michael [4 ]
Hall, Richard M. [4 ]
Persson, Cecilia [1 ]
机构
[1] Uppsala Univ, Dept Mat Sci & Engn, Uppsala, Sweden
[2] Univ Technol Sydney, Sch Biomed Engn, Sydney, NSW, Australia
[3] Ionbond UK Ltd, Consett, England
[4] Univ Leeds, Dept Mech Engn, Leeds, W Yorkshire, England
关键词
Joint implants; Coatings; Surface layers; Ceramics; Biomaterials; Wear resistance; DIAMOND-LIKE-CARBON; ZIRCONIUM FEMORAL COMPONENT; 5-YEAR FOLLOW-UP; CO-CR-MO; SILICON-NITRIDE; OXIDIZED ZIRCONIUM; IN-VITRO; NANOCRYSTALLINE DIAMOND; TRIBOLOGICAL BEHAVIOR; RETRIEVAL ANALYSIS;
D O I
10.1016/j.mtbio.2022.100270
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hip and knee joint replacements are common and largely successful procedures that utilise implants to restore mobility and relieve pain for patients suffering from e.g. osteoarthritis. However, metallic ions and particles released from both the bearing surfaces and non-articulating interfaces, as in modular components, can cause hypersensitivity and local tissue necrosis, while particles originating from a polymer component have been associated with aseptic loosening and osteolysis. Implant coatings have the potential to improve properties compared to both bulk metal and ceramic alternatives. Ceramic coatings have the potential to increase scratch resistance, enhance wettability and reduce wear of the articulating surfaces compared to the metallic substrate, whilst maintaining overall toughness of the implant ensuring a lower risk of catastrophic failure of the device compared to use of a bulk ceramic. Coatings can also act as barriers to inhibit ion release from the underlying material caused by corrosion. This review aims to provide a comprehensive overview of wear-resistant coatings for joint replacements - both those that are in current clinical use as well as those under investigation for future use. While the majority of coatings belong predominantly in the latter group, a few coated implants have been successfully marketed and are available for clinical use in specific applications. Commercially available coatings for implants include titanium nitride (TiN), titanium niobium nitride (TiNbN), oxidized zirconium (OxZr) and zirconium nitride (ZrN) based coatings, whereas current research is focused not only on these, but also on diamond-like-carbon (DLC), silicon nitride (SiN), chromium nitride (CrN) and tantalum-based coatings (TaN and TaO). The coating materials referred to above that are still at the research stage have been shown to be noncytotoxic and to reduce wear in a laboratory setting. However, the adhesion of implant coatings remains a main area of concern, as poor adhesion can cause delamination and excessive wear. In clinical applications zirconium implant surfaces treated to achieve a zirconium oxide film and TiNbN coated implants have however been proven comparable to traditional cobalt chromium implants with regards to revision numbers. In addition, the chromium ion levels measured in the plasma of patients were lower and allergy symptoms were relieved. Therefore, coated implants could be considered an alternative to uncoated metal implants, in particular for patients with metal hypersensitivity. There have also been unsuccessful introductions to the market, such as DLC coated implants, and therefore this review also attempts to summarize the lessons learnt.
引用
收藏
页数:14
相关论文
共 20 条
  • [1] Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants
    Skjöldebrand, Charlotte
    Tipper, Joanne L.
    Hatto, Peter
    Bryant, Michael
    Hall, Richard M.
    Persson, Cecilia
    Materials Today Bio, 2022, 15
  • [2] WEAR-RESISTANT COATINGS: THEIR EVOLUTION AS FIBER CONTACT SURFACES.
    Leimer, Rollo M.
    Fiber Producer, 1980, 8 (05): : 32 - 42
  • [3] Highly wear-resistant and biocompatible carbon nanocomposite coatings for dental implants
    Penkov, Oleksiy V.
    Pukha, Vladimir E.
    Starikova, Svetlana L.
    Khadem, Mahdi
    Starikov, Vadym V.
    Maleev, Maxim V.
    Kim, Dae-Eun
    BIOMATERIALS, 2016, 102 : 130 - 136
  • [4] Research of Thermomechanical Processes When Processing Cylindrical Surfaces with Wear-Resistant Coatings
    Kunitsyn, Maksym
    Usov, Anatoly
    ADVANCES IN DESIGN, SIMULATION AND MANUFACTURING III: MANUFACTURING AND MATERIALS ENGINEERING, VOL 1, 2020, : 390 - 400
  • [5] The Surfaces Properties of Steel Parts with Wear-Resistant Coatings of the 1М and 90 % ВК6
    Tarelnyk, V. B.
    Gaponova, O. P.
    Tarelnyk, N., V
    Konoplianchenko, E., V
    Bondarev, S. G.
    Radionov, O., V
    Mayfat, M. M.
    Okhrimenko, A., V
    Dumanchuk, M. Yu.
    Sirovitskiy, K. G.
    METALLOPHYSICS AND ADVANCED TECHNOLOGIES, 2023, 45 (06)
  • [6] Improvement of a Stochastic Dynamic Model for Grinding of Cylindrical Surfaces with Wear-Resistant Coatings
    Kunitsyff, Maksym
    Usov, Anatoly
    ADVANCED MANUFACTURING PROCESSES II, 2021, : 534 - 544
  • [7] Cochlear implants: current status and future potential
    Cosetti, Maura K.
    Waltzman, Susan B.
    EXPERT REVIEW OF MEDICAL DEVICES, 2011, 8 (03) : 389 - 401
  • [8] Properties of Surfaces of Steel Parts with Wear-Resistant Coatings of the 1М and 90% BК6
    Tarelnyk, V. B.
    Gaponova, Oksana Petrivna
    Melnyk, V. I.
    Tarelnyk, N., V
    Zubko, V. M.
    Vlasovets, V. M.
    Konoplianchenko, Ie., V
    Bondarev, S. G.
    Radionov, O., V
    Mayfat, M. M.
    Okhrimenko, V. O.
    Tkachenko, A., V
    METALLOPHYSICS AND ADVANCED TECHNOLOGIES, 2023, 45 (05)
  • [9] On the mechanism of formation of wear-resistant coatings on the friction surfaces of technical products in the presence of these drugs Tribo
    Sharifullin, S. N.
    Dunayev, A. V.
    INTERNATIONAL SCIENTIFIC-TECHNICAL CONFERENCE ON INNOVATIVE ENGINEERING TECHNOLOGIES, EQUIPMENT AND MATERIALS 2015 (ISTC-IETEM-2015), 2016, 134
  • [10] Potential of wear resistant coatings on Ti-6Al-4V for artificial hip joint bearing surfaces
    Oesterle, W.
    Klaffke, D.
    Griepentrog, M.
    Gross, U.
    Kranz, I.
    Knabe, Ch.
    WEAR, 2008, 264 (7-8) : 505 - 517