Single lag screw and reverse distal femur locking compression plate for concurrent cervicotrochanteric and shaft fractures of the femur: biomechanical study validated with a clinical series

被引:8
|
作者
Jitprapaikulsarn, Surasak [1 ]
Chantarapanich, Nattapon [2 ]
Gromprasit, Arthit [1 ]
Mahaisavariya, Chantas [3 ]
Patamamongkonchai, Chawanan [1 ]
机构
[1] Buddhachinaraj Hosp, Dept Orthoped, Phitsanulok, Thailand
[2] Kasetsart Univ, Fac Engn Sriracha, Dept Mech Engn, Sriracha, Chonburi, Thailand
[3] Mahidol Univ, Siriraj Hosp, Fac Med, Golden Jubilee Med Ctr, Bangkok, Thailand
关键词
Concurrent cervicotrochanteric; Shaft fractures of the femur; Single lag screw and reverse LCP-DF; IPSILATERAL FEMORAL-NECK; PROXIMAL FEMUR; HIP; FIXATION;
D O I
10.1007/s00590-020-02868-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe optimal surgical management of concurrent cervicotrochanteric and shaft fractures of the femur has not been consensual. The authors investigated the reliability of combined single lag screw and reverse distal femur locking compression plate (LCP-DF) by finite element (FE) study and retrospectively described the present technique for these dual fractures.MethodIntact femurs were derived from CT data, and the implant models were created by using CAD software. The fractured femur and implant models were virtually aligned based on the surgical techniques before converting to the FE model. In the FE model, applied boundary conditions included body weight, muscle forces, and constraint of the joints. Regarding clinical series, three patients with these dual fractures of the femur and 2 with cervicotrochanteric fractures with subtrochanteric extension were operated on by the proposed technique. The collected data include operative time, postoperative complications, union times, and clinical outcomes.ResultsEquivalent von Mises stress exhibited on dynamic hip screws with an anti-rotational screw was higher than the other techniques, close to the yield stress of the material. Multiple screw fixation produced better stability for transcervical fractures whereas the proposed technique of combined single lag screw and reverse LCP-DF provided better stability for intertrochanteric fractures. No significant difference in cortical bone stress was found between multiple screw construct and the proposed technique. The proposed technique presented a lower risk of secondary fractures, as the strain energy density (SED) in cancellous bone was lower than multiple screw construct. Regarding clinical series, all fractures were united with a mean union time of-16.1 weeks (range 12-20). There were no any postoperative complications. Regarding the Harris score, 1 was determined to be excellent value, and 4 to be good.ConclusionBy the FE results, a combination of a single lag screw and reverse LCP-DF is an effective technique for fixation of cervicotrochanteric fractures. Empowered by the clinical results, this proposed technique could be an alternative for concurrent cervicotrochanteric and shaft fractures of the femur especially when either single-system or dual-system devices seem not to be suitable.
引用
收藏
页码:1179 / 1192
页数:14
相关论文
共 48 条
  • [1] Single lag screw and reverse distal femur locking compression plate for concurrent cervicotrochanteric and shaft fractures of the femur: biomechanical study validated with a clinical series
    Surasak Jitprapaikulsarn
    Nattapon Chantarapanich
    Arthit Gromprasit
    Chantas Mahaisavariya
    Chawanan Patamamongkonchai
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2021, 31 : 1179 - 1192
  • [2] A BIOMECHANICAL ANALYSIS ABOUT FIXING THE LOCKING COMPRESSION PLATE OF DISTAL FEMUR FRACTURES
    Park, I.
    Oh, C.
    Lee, J.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2019, 30 : S469 - S470
  • [3] A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures
    Singh, Ashutosh Kumar
    Narsaria, N.
    Gupta, R. K.
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (10): : 2050 - 2053
  • [4] Polyaxial locking plate fixation in distal femur fractures: A biomechanical comparison
    Wilkens, Kenneth J.
    Curtiss, Shane
    Lee, Mark A.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) : 624 - 628
  • [5] Letter to the editor concerning "A biomechanical study comparing proximal femur nail and proximal femur locking compression plate in fixation of reverse oblique proximal femur fractures"
    Imerci, Ahmet
    Aydogan, Nevres Hurriyet
    Erciyes, Oguzhan Samil
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2018, 49 (03): : 734 - 735
  • [6] The utility of reverse distal femur locking compression plate in minimally invasive osteosynthesis for type C subtrochanteric fractures of the femur: technical description and a clinical series of 50 cases
    Surasak Jitprapaikulsarn
    Arthit Gromprasit
    Kritsada Sukha
    Chawanan Patamamongkonchai
    Apipop Kritsaneephaiboon
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 1423 - 1433
  • [7] The utility of reverse distal femur locking compression plate in minimally invasive osteosynthesis for type C subtrochanteric fractures of the femur: technical description and a clinical series of 50 cases
    Jitprapaikulsarn, Surasak
    Gromprasit, Arthit
    Sukha, Kritsada
    Patamamongkonchai, Chawanan
    Kritsaneephaiboon, Apipop
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (07): : 1423 - 1433
  • [8] Nonvascularized fibular graft with locking screw fixation for metaphyseal bone loss of distal femur: biomechanical assessment validated by a clinical case series
    Surasak Jitprapaikulsarn
    Nattapon Chantarapanich
    Arthit Gromprasit
    Chantas Mahaisavariya
    Kritsada Sukha
    Ployphailin Rungsakaolert
    [J]. European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 (1) : 659 - 671
  • [9] Nonvascularized fibular graft with locking screw fixation for metaphyseal bone loss of distal femur: biomechanical assessment validated by a clinical case series
    Jitprapaikulsarn, Surasak
    Chantarapanich, Nattapon
    Gromprasit, Arthit
    Mahaisavariya, Chantas
    Sukha, Kritsada
    Rungsakaolert, Ployphailin
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01): : 659 - 671
  • [10] Osteosynthesis by locking compression plate for periprosthetic fractures of the distal femur after knee arthroplasty
    Ehlinger, Matthieu
    Adam, Philippe
    Bonnomet, Francois
    Arlettaz, Yvan
    [J]. SWISS MEDICAL WEEKLY, 2011, 141 : 20S - 20S