Residual capacity of corroded reinforcing bars

被引:540
|
作者
Du, YG [1 ]
Clark, LA
Chan, AHC
机构
[1] Edinburghs Telford Coll, Sch Bldg & Engn, Edinburgh EH4 2NZ, Midlothian, Scotland
[2] Univ Birmingham, Dept Civil Engn, Birmingham B15 2TT, W Midlands, England
关键词
D O I
10.1680/macr.57.3.135.60482
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an experimental investigation into the residual capacity of corroded reinforcing bars. By performing both accelerated and simulated corrosion tests on bare bars and on bars embedded in concrete, the mechanism of the reduction of the capacity of corroded reinforcement was investigated. The influence of type and diameter of reinforcement on its residual capacity is discussed. The experimental results show that, due to local attack penetration, the residual cross-section of a corroded bar is no longer round and varies considerably along its circumference and its length. Although the force-extension curves of corroded bars are similar to those of non-corroded bars for up to 16% corrosion, their residual yield and ultimate forces decrease more rapidly than their average cross-sectional area and, therefore, their residual strength decreases significantly. Even though the residual capacity of corroded small diameter and/or plain bars reduces more than that of large diameter or ribbed ones, differences are not significant and can be neglected. Finally, a simple equation is proposed to predict the residual capacity of corroded reinforcing bars in practice.
引用
收藏
页码:135 / 147
页数:13
相关论文
共 50 条
  • [1] EXPERIMENTAL STUDY ON THE RESIDUAL CAPACITY OF CORRODED REINFORCING BARS
    Xu, Gang
    Ai, Tian-Cheng
    Zhang, Wei-Jun
    Wang, Qing
    4TH INTERNATIONAL SYMPOSIUM ON LIFETIME ENGINEERING OF CIVIL INFRASTRUCTURE, 2009, : 424 - 429
  • [2] Model for degeneration in bearing capacity of concrete beams with corroded reinforcing bars
    School of Civil Engineering and Architecture, Anhui University of Science and Technology, Huainan 232001, China
    不详
    Zhongguo Kuangye Daxue Xuebao, 2008, 4 (509-513):
  • [3] Effect of Loading Rate on the Bond Capacity Between the Corroded Reinforcing Bars and Concrete
    Jin L.
    Zhang X.
    Guo L.
    Wu J.
    Du X.
    Cailiao Daobao/Materials Reports, 2024, 38 (08):
  • [4] Deformation capacity of FRP retrofitted reinforced concrete columns with corroded reinforcing bars
    Dai, Kuang-Yu
    Yu, Xiao-Hui
    Qian, Kai
    Wang, Dai-Yu
    ENGINEERING STRUCTURES, 2022, 254
  • [5] A new prediction model for residual deformation capacity of corroded steel bars
    Liu, Yifan
    Miao, Zhiwei
    Hogan, Lucas
    Zhu, Mingliang
    Lu, Yong
    ENGINEERING STRUCTURES, 2024, 318
  • [6] Bond capacity of severely corroded bars with corroded stirrups
    Hanjari, Kamyab Zandi
    Coronelli, Dario
    Lundgren, Karin
    MAGAZINE OF CONCRETE RESEARCH, 2011, 63 (12) : 953 - 968
  • [7] Bond behaviour of corroded reinforcing steel bars in concrete
    Fang, Congqi
    Lundgren, Karin
    Plos, Mario
    Gylltoft, Kent
    CEMENT AND CONCRETE RESEARCH, 2006, 36 (10) : 1931 - 1938
  • [8] Bond of naturally corroded, plain reinforcing bars in concrete
    Robuschi, Samanta
    Sumearll, Jakob
    Fernandez, Ignasi
    Lundgren, Karin
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2021, 17 (06) : 792 - 808
  • [9] Cyclic behaviour of uncorroded and corroded steel reinforcing bars
    Caprili, Silvia
    Salvatore, Walter
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 76 : 168 - 186
  • [10] Non-linear analysis of buckling carrying capacity for corroded reinforcing bars based on ANSYS
    Jiang, Fengchan
    Zhu, Cimian
    Xue, Jiansheng
    Zhao, Yinghao
    Tongji Daxue Xuebao/Journal of Tongji University, 2008, 36 (08): : 1045 - 1049