ASSESSMENT OF ANNUAL EFFECTIVE DOSE DUE TO THE INDOOR RADON EXPOSURE IN A SECOND-DEGREE EARTHQUAKE ZONE OF KUTAHYA (TURKEY)

被引:0
|
作者
Sahin, L. [1 ]
Cetinkaya, H. [2 ]
Gelgun, S. [2 ]
机构
[1] Istanbul Univ, Dept Phys, TR-34134 Istanbul, Turkey
[2] Dumlupinar Univ, Dept Phys, TR-43000 Kutahya, Turkey
来源
ROMANIAN JOURNAL OF PHYSICS | 2016年 / 61卷 / 3-4期
关键词
Radon; LR-115; Film; Natural radiation; Dose equivalent/effective dose; RADIOACTIVITY MEASUREMENTS; RN-222; CONCENTRATIONS; CANCER-RISK; DWELLINGS; PROVINCE; CITY; PAKISTAN; INDIA;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Indoor radon concentrations have been measured in 100 dwellings of Central Kutahya, Turkey, using LR-115 type II Solid-State Nuclear Track Detectors. The detectors were placed in living rooms during the period of March May 2010 for three times. The annual indoor radon concentrations vary from 74.1+/-2.4 to 272.3 +/- 4.2 Bq m(-3), with a mean value of 120.8 +/- 2.0 Bq m(-3). Based on these results, we find an annual effective dose varying from 1.9 to 6.9 mSv, with a mean value of 3 mSv y(-1) received by inhabitants living in Kutahya city.
引用
收藏
页码:687 / 696
页数:10
相关论文
共 14 条
  • [1] Assessment of Annual Effective Dose Due to the Indoor Radon Exposure in Districts Bagh and Kahuta of the Azad Kashmir, Pakistan
    Rafique, Muhammad
    Malik, Fariha
    Matiullah
    Manzoor, Najma
    Rajput, M. U.
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (03) : 458 - 464
  • [2] Annual effective dose of radon due to exposure in indoor air and groundwater in Bathinda district of Punjab
    Mehra, Rohit
    Kaur, Kirandeep
    Bangotra, Pargin
    INDOOR AND BUILT ENVIRONMENT, 2016, 25 (05) : 848 - 856
  • [3] ASSESSMENT OF DOSE DUE TO EXPOSURE TO INDOOR RADON AND THORON PROGENY
    Prasad, Ganesh
    Gusain, Gurupad S.
    Joshi, Veena
    Ramola, Rakesh C.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2010, 25 (03): : 198 - 204
  • [4] Assessment of annual effective dose and health risk due to radon exposure in nurseries in the city of Poznan, Poland
    Kubiak, J.
    Basinska, M.
    BUILDING AND ENVIRONMENT, 2023, 244
  • [5] Assessment of annual effective dose from the indoor radon in Bathinda District of Punjab in India
    Arora, Amit
    Mehra, Rohit
    Garg, Rajeev Kumar
    Tyagi, Anand K.
    Nature Environment and Pollution Technology, 2019, 18 (04): : 1471 - 1478
  • [6] ANNUAL EFFECTIVE DOSE ASSESSMENT DUE TO RADON AND THORON PROGENIES IN DWELLINGS OF KILIMAMBOGO, KENYA
    Nyambura, C.
    Tokonami, S.
    Hashim, N. O.
    Chege, M. W.
    Suzuki, T.
    Kudo, H.
    Hosoda, M.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (3-4) : 430 - 434
  • [7] Variation of Annual Effective Dose Due to Radon Level in Indoor Air in Marwar Region of Rajasthan, India
    Rani, Asha
    Mittal, Sudhir
    Mehra, Rohit
    ADVANCED MATERIALS AND RADIATION PHYSICS (AMRP-2015), 2015, 1675
  • [8] Investigation of indoor radon concentration in dwellings of Aleshtar (western part of Iran) and estimation of the annual effective dose from exposure to radon
    Hassanvand, H.
    Birjandi, M.
    Amiri, A.
    Hassanvand, M. S.
    Kamarehie, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (04): : 659 - 666
  • [9] MEASUREMENTS IN AFGHANISTAN USING AN ACTIVE RADON EXPOSURE METER AND ASSESSMENT OF RELATED ANNUAL EFFECTIVE DOSE
    Tanha, Mohammad R.
    Vahlbruch, Jan-Willem
    Riebe, Beate
    Irlinger, Josef
    Ruehm, Werner
    Khalid, Fazal R.
    Storai, Abobaker
    Walther, Clemens
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 122 - 130
  • [10] Estimation of annual effective dose due to Radon level in indoor air and soil gas in Hamirpur district of Himachal Pradesh
    Mehra, Rohit
    Bala, Pankaj
    JOURNAL OF GEOCHEMICAL EXPLORATION, 2014, 142 : 16 - 20