Automated fluorescence gating and size determination reduce variation in measured concentration of extracellular vesicles by flow cytometry

被引:5
|
作者
Gankema, Angela Adriana Francisca [1 ,2 ]
Li, Bo [1 ,2 ,3 ]
Nieuwland, Rienk [1 ,2 ]
van der Pol, Edwin [1 ,2 ,4 ]
机构
[1] Amsterdam UMC, Lab Expt Clin Chem, Amsterdam, Netherlands
[2] Univ Amsterdam, Vesicle Observat Ctr, Amsterdam UMC, Amsterdam, Netherlands
[3] Southern Med Univ, Nanfang Hosp, Dept Lab Med, Guangzhou, Peoples R China
[4] Amsterdam UMC, Dept Biomed Engn & Phys, Amsterdam, Netherlands
基金
欧盟地平线“2020”;
关键词
automation; detection limit; extracellular vesicles; flow cytometry; fluorophores; immunostaining; inter-operator variability; light scattering; sensitivity; standardization;
D O I
10.1002/cyto.a.24665
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Extracellular vesicles (EVs) are an upcoming biomarker for disease. However, the measured concentrations of EVs by flow cytometry are incomparable due to analytical variables. This study aimed to investigate how the choice of fluorophore, and thereby brightness, affects the measured concentration of EVs. Four commonly used fluorophores allophycocyanin, Brilliant Violet-421, fluorescein isothiocyanate, and phycoerythrin, all conjugated to CD61 antibodies, were used to label platelet-derived extracellular vesicles (PEVs) in human plasma. PEVs were measured by flow cytometry. The concentration of EVs was obtained by manually set fluorescence gates, automatically determined fluorescence gates, and automatically determined fluorescence gates combined with specific size gates. Manually set fluorescence gates by five independent experts resulted in a variation coefficient (CV) of 41% between the measured PEV concentrations labeled with the four different fluorophores. A new algorithm for automatic determination of fluorescence gates was applied to reduce inter-operator variability. Applying this algorithm resulted in a CV of 58%. However, when the algorithm was combined with a size gate to correct for differences in brightness between fluorophores, the CV reduced to 25%. In this study, we showed that different fluorophores can detect similar concentrations of EVs by (1) determining fluorescence gates automatically, and (2) by adding a size gate to correct for differences in brightness between fluorophores. Therefore, our research contributes to further standardization of EV concentration measurements by flow cytometry.
引用
收藏
页码:1049 / 1056
页数:8
相关论文
共 24 条
  • [1] Size Determination and Phenotypic Analysis of Urinary Extracellular Vesicles using Flow Cytometry
    Cecilia Navarro-Hernandez, Itze
    Acevedo-Ochoa, Ernesto
    Juarez-Vega, Guillermo
    Eduardo Meza-Sanchez, David
    Manuel Hernandez-Hernandez, Jose
    Luis Maravillas-Montero, Jose
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (170):
  • [2] Diurnal Variations of Circulating Extracellular Vesicles Measured by Nano Flow Cytometry
    Danielson, Kirsty M.
    Estanislau, Jessica
    Tigges, John
    Toxavidis, Vasilis
    Camacho, Virginia
    Felton, Edward J.
    Khoory, Joseph
    Kreimer, Simion
    Ivanov, Alexander R.
    Mantel, Pierre-Yves
    Jones, Jennifer
    Akuthota, Praveen
    Das, Saumya
    Ghiran, Ionita
    PLOS ONE, 2016, 11 (01):
  • [3] Measurement of Extracellular Vesicles and Other Submicron Size Particles by Flow Cytometry
    Lannigan, Joanne
    Nolan, John P.
    Zucker, Robert
    CYTOMETRY PART A, 2016, 89A (02) : 109 - 110
  • [4] Physical interpretation of the size and concentration of extracellular vesicles measured by advanced techniques
    Van der Pol, E.
    Gardiner, C.
    Harrison, P.
    Sturk, A.
    Van Leeuwen, T. G.
    Nieuwland, R.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 22 - 22
  • [5] Fluorescence Triggering: A General Strategy for Enumerating and Phenotyping Extracellular Vesicles by Flow Cytometry
    Arraud, Nicolas
    Gounou, Celine
    Turpin, Delphine
    Brisson, Alain R.
    CYTOMETRY PART A, 2016, 89A (02) : 184 - 195
  • [6] PARTICLE SIZE DETERMINATION IN IMPEDANCE FLOW CYTOMETRY USING MEASURED OPACITY
    de Bruijn, Douwe S.
    Jorissen, Koen F. A.
    Olthuis, Wouter
    van den Berg, Albert
    2021 21ST INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2021, : 1036 - 1039
  • [7] Size and concentration analyses of extracellular vesicles by nanoparticle tracking analysis: a variation study
    Vestad, Beate
    Llorente, Alicia
    Neurauter, Axl
    Phuyal, Santosh
    Kierulf, Bente
    Kierulf, Peter
    Skotland, Tore
    Sandvig, Kirsten
    Haug, Kari Bente F.
    Ovstebo, Reidun
    JOURNAL OF EXTRACELLULAR VESICLES, 2017, 6 (01): : 1 - 11
  • [8] Extracellular vesicles from blood plasma: determination of their morphology, size, phenotype and concentration
    Arraud, N.
    Linares, R.
    Tan, S.
    Gounou, C.
    Pasquet, J. -M.
    Mornet, S.
    Brisson, A. R.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2014, 12 (05) : 614 - 627
  • [9] Optimisation of imaging flow cytometry for the analysis of single extracellular vesicles by using fluorescence-tagged vesicles as biological reference material
    Goergens, Andre
    Bremer, Michel
    Ferrer-Tur, Rita
    Murke, Florian
    Tertel, Tobias
    Horn, Peter A.
    Thalman, Sebastian
    Welsh, Joshua A.
    Probst, Christine
    Guerin, Coralie
    Boulanger, Chantal M.
    Jones, Jennifer C.
    Hanenber, Helmut
    Erdbrugger, Uta
    Lannigan, Joanne
    Ricklefs, Franz L.
    El-Andaloussi, Samir
    Giebel, Bernd
    JOURNAL OF EXTRACELLULAR VESICLES, 2019, 8 (01)
  • [10] Intrinsic variability of fluorescence calibrators impacts the assignment of MESF or ERF values to nanoparticles and extracellular vesicles by flow cytometry
    Lozano-Andres, Estefania
    Van den Broeck, Tina
    Wang, Lili
    Mehrpouyan, Majid
    Tian, Ye
    Yan, Xiaomei
    Arkesteijn, Ger J. A.
    Wauben, Marca H. M.
    NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE, 2024, 56