Enabling quantification of protein concentration in human serum biopsies using attenuated total reflectance - Fourier transform infrared (ATR-FTIR) spectroscopy

被引:35
|
作者
Spalding, Katie [1 ]
Bonnier, Franck [2 ]
Bruno, Clement [2 ]
Blasco, Helene [3 ,4 ]
Board, Ruth [5 ]
Benz-de Bretagne, Isabelle [3 ,4 ]
Byrne, Hugh J. [6 ]
Butler, Holly J. [1 ]
Chourpa, Igor [2 ]
Radhakrishnan, Pretheepan [1 ,7 ]
Baker, Matthew J. [1 ]
机构
[1] Univ Strathclyde, Technol & Innovat Ctr, Dept Pure & Appl Chem, WestCHEM, Glasgow G1 1RD, Lanark, Scotland
[2] Univ Francois Rabelais Tours, Fac Pharm, EA Nanomedicaments & Nanosondes 6295, 31 Ave Monge, F-37200 Tours, France
[3] CHRU Tours, Lab Biochim & Biol Mol, Tours, France
[4] Univ Tours, INSERM, U930, Tours, France
[5] Lancashire Teaching Hosp NHS Trust, Rosemere Canc Ctr, Royal Preston Hosp, Sharoe Green Lane, Preston PR2 9HT, Lancs, England
[6] Dublin Inst Technol, FOCAS Res Inst, Kevin St, Dublin 8, Ireland
[7] Univ Strathclyde, Technol & Innovat Ctr, Dept Biomed Engn, CDT Med Devices & Hlth Technol, Glasgow G1 1RD, Lanark, Scotland
关键词
Protein; Infrared; Attenuated total reflection; Serum; Clinical; Quantification; DIAGNOSIS; DISCRIMINATION; BIOMARKERS; CANCER;
D O I
10.1016/j.vibspec.2018.08.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Changes in protein concentrations within human blood are used as an indicator for nutritional state, hydration and underlying illnesses. They are often measured at regular clinical appointments and the current analytical process can result in long waiting times for results and the need for return patient visits. Attenuated total reflectance- Fourier transform infrared (ATR-FTIR) spectroscopy has the ability to detect minor molecular differences, qualitatively and quantitatively, in biofluid samples, without extensive sample preparation. ATR-FTIR can return an analytical measurement almost instantaneously and therefore could be deemed as an ideal technique for monitoring molecular alterations in blood within the clinic. To determine the suitability of using ATR-FTIR spectroscopy to enable protein quantification in a clinical setting, pooled human serum samples spiked with varying concentrations of human serum albumin (HSA) and immunoglobulin G (IgG) were analysed, before analysing patient clinical samples. Using a validated partial least squares method, the spiked samples (IgG) produced a linearity as high as 0.998 and a RMSEV of 0.49 +/- 0.05 mg mL(-1), with the patient samples producing R-2 values of 0.992 and a corresponding RMSEV of 0.66 +/- 0.05 mg mL(-1). This claim was validated using two blind testing models, leave one patient out cross validation and k-fold cross validation, achieving optimum linearity and RMSEV values of 0.934 and 1.99 +/- 0.79 mg mL(-1), respectively. This demonstrates that ATR-FTIR is able to quantify protein within clinically relevant complex matrices and concentrations, such as serum samples, rapidly and with simple sample preparation. The ability to provide a quantification step, along with rapid disease classification, from a spectroscopic signature will aid clinical translation of vibrational spectroscopy to assist with problems currently faced with patient diagnostic pathways.
引用
收藏
页码:50 / 58
页数:9
相关论文
共 50 条
  • [1] Rapid Quantification of Methamphetamine: Using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR) and Chemometrics
    Hughes, Juanita
    Ayoko, Godwin
    Collett, Simon
    Golding, Gary
    [J]. PLOS ONE, 2013, 8 (07):
  • [2] Rapid quantification of isoflurane in anesthetic nanoemulsions using Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR)
    Tootoonchi, Mohammad Hossein
    Bardsley, Ryan
    Panagiotou, Thomai
    Fisher, Robert J.
    Pretto, Ernesto A., Jr.
    Fraker, Christopher A.
    [J]. VIBRATIONAL SPECTROSCOPY, 2020, 109
  • [3] Forensic classification of lipsticks using attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy
    Kaur, Kiranpreet
    Yadav, Praveen Kumar
    Bumbrah, Gurvinder Singh
    Sharma, Rakesh Mohan
    [J]. VIBRATIONAL SPECTROSCOPY, 2020, 110
  • [4] Detection and quantification of soymilk in cow-buffalo milk using Attenuated Total Reflectance Fourier Transform Infrared spectroscopy (ATR-FTIR)
    Jaiswal, Pranita
    Jha, Shyam Narayan
    Borah, Anjan
    Gautam, Anuj
    Grewal, Manpreet Kaur
    Jindal, Gaurav
    [J]. FOOD CHEMISTRY, 2015, 168 : 41 - 47
  • [5] Historical perspective and modern applications of Attenuated Total Reflectance - Fourier Transform Infrared Spectroscopy (ATR-FTIR)
    Blum, Marc-Michael
    John, Harald
    [J]. DRUG TESTING AND ANALYSIS, 2012, 4 (3-4) : 298 - 302
  • [6] Trends of Forensic Analysis of Pen Ink Using Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) Spectroscopy
    Khofar, Putri Nabihah Abdul
    Karim, Umi Kalsum Abdul
    Elias, Ezlan
    Safian, Muhd Fauzi
    Halim, Mohamed Izzharif Abdul
    [J]. INDONESIAN JOURNAL OF CHEMISTRY, 2022, 22 (04) : 1144 - 1154
  • [7] Quantification of Lactobacillus reuteri ProTectis in MRS Broth Using Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) Spectroscopy and Chemometrics
    Bautista, Norwell Brian C.
    Dumancas, Gerard G.
    Ubas, Johnziel G.
    Bandeling, Eleo Jean D.
    Seduco, Rhett Adrian C.
    Martizano, Jay O.
    Janagap, Steve P.
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2023, 71 (48) : 19101 - 19110
  • [8] Attenuated Total Reflectance - Fourier Transform Infrared (ATR-FTIR) Spectroscopy: A Tool to Determine Groundnut Seed Quality
    Eevera, T.
    Chinnasamy, G. P.
    Venkatesan, S.
    Navamaniraj, K. Nelson
    Albert, V. Alex
    Anandhan, J.
    [J]. LEGUME RESEARCH, 2024, 47 (07) : 1165 - 1171
  • [9] Measuring Dermal Exposure to Pesticide Residues with Attenuated Total Reflectance Fourier Transform Infrared (ATR-FTIR) Spectroscopy
    E. M. Doran
    M. G. Yost
    R. A. Fenske
    [J]. Bulletin of Environmental Contamination and Toxicology, 2000, 64 : 666 - 672
  • [10] Measuring dermal exposure to pesticide residues with attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy
    Doran, EM
    Yost, MG
    Fenske, RA
    [J]. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2000, 64 (05) : 666 - 672