Sagittal Stability and Implant Design Affect Patient Reported Outcomes After Total Knee Arthroplasty

被引:27
|
作者
Jones, Christopher W. [1 ,2 ,3 ]
Jacobs, Hans [4 ]
Shumborski, Sarah [5 ]
Talbot, Simon [6 ]
Redgment, Andrew [7 ]
Brighton, Roger [8 ]
Walter, William L. [3 ,9 ]
机构
[1] Fiona Stanley Hosp Grp & Orthopaed WA, Perth, WA, Australia
[2] Curtin Univ, Perth, WA, Australia
[3] Univ Sydney, Sydney, NSW, Australia
[4] Univ Pretoria, Steve Biko Acad Hosp, Pretoria, South Africa
[5] Mater Hosp, Sydney, NSW, Australia
[6] Western Hlth, Dept Orthopaed, Melbourne, Vic, Australia
[7] Wagga Private Hosp, Wagga, Australia
[8] Westmead Private Hosp, Sydney, NSW, Australia
[9] Royal North Shore Hosp, Northern Local Area Hlth Dist, Sydney, NSW, Australia
来源
JOURNAL OF ARTHROPLASTY | 2020年 / 35卷 / 03期
关键词
total knee arthroplasty; sagittal stability; KT-1000; medially stabilized; medial pivot; patient reported outcome measures; MEDIAL PIVOT; IN-VIVO; REPLACEMENT; LAXITY; JOINT;
D O I
10.1016/j.arth.2019.10.020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Joint stability is one of the goals of any joint replacement. The contribution of prosthesis design to sagittal stability in total knee arthroplasty (TKA) has emerged as an area of interest. The purpose of this study was to evaluate the sagittal stability of four prosthesis types and determine the effect on patient reported outcome measures (PROMs). Methods: A matched-cohort cross-sectional study was performed on 60 patients after TKA at 1-year follow-up. Three surgeons performed 10 medially stabilized (MS) TKA and 10 non-MS TKA. Sagittal stability was assessed by a blinded observer using a KT-1000 arthrometer, Lachman's test, and the anterior drawer test. PROMs (Oxford, Knee Injury and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Osteoarthritis Index, Forgotten joint score) and visual analog scale assessed function and satisfaction. Results: MS TKA had significantly decreased translation on KT-1000 and improved stability compared with non-MS TKA (P < .05). Increased PROMs were demonstrated in the MS TKA group compared with the non-MS TKA group (P < .05). When divided based on objective stability, regardless of the prosthesis type, patients with a stable knee had superior PROMs (P < .05), particularly in sport-related questions. Conclusion: The MS TKA had significantly greater sagittal stability, improved PROMs, and satisfaction compared with non-MS TKA. Independent of prosthesis design, patients with greater sagittal stability demonstrated improved PROMs. (c) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:747 / 751
页数:5
相关论文
共 50 条
  • [1] Does design change in total knee arthroplasty implants affect patient-reported outcomes?
    Toossi, Nader
    Bucklen, Brandon
    Meding, Lindsey K.
    Meding, John B.
    [J]. BMC SURGERY, 2023, 23 (01)
  • [2] Does design change in total knee arthroplasty implants affect patient-reported outcomes?
    Nader Toossi
    Brandon Bucklen
    Lindsey K. Meding
    John B. Meding
    [J]. BMC Surgery, 23
  • [3] Patellar tilt does not affect patient reported outcomes after modern total knee arthroplasty
    Naveen, Neal B.
    Deckard, Evan R.
    Ziemba-Davis, Mary
    Hanson, Logan F.
    Warth, Lucian C.
    Meneghini, R. Michael
    [J]. KNEE, 2022, 34 : 167 - 177
  • [4] Patient reported outcomes and implant survivorship after Total knee arthroplasty with the persona knee implant system: two year follow up
    Mathijssen, N. M. C.
    Verburg, H.
    London, N. J.
    Landsiedl, M.
    Dominkus, M.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (1)
  • [5] Patient reported outcomes and implant survivorship after Total knee arthroplasty with the persona knee implant system: two year follow up
    N. M. C. Mathijssen
    H. Verburg
    N. J. London
    M. Landsiedl
    M. Dominkus
    [J]. BMC Musculoskeletal Disorders, 20
  • [6] Variations In Good Patient Reported Outcomes After Total Knee Arthroplasty
    Kiran, Amit
    Bottomley, Nicholas
    Biant, Leela C.
    Javaid, M. Kassim
    Carr, Andrew J.
    Cooper, Cyrus
    Field, Richard E.
    Murray, David W.
    Price, Andrew
    Beard, David J.
    Arden, Nigel K.
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (08): : 1364 - 1371
  • [7] Implant design influences patient outcome after total knee arthroplasty
    Hamilton, D. F.
    Burnett, R.
    Patton, J. T.
    Howie, C. R.
    Moran, M.
    Simpson, A. H. R. W.
    Gaston, P.
    [J]. BONE & JOINT JOURNAL, 2015, 97B (01): : 64 - 70
  • [8] Tramadol in Knee Osteoarthritis: Does Preoperative Use Affect Patient-Reported Outcomes After Total Knee Arthroplasty?
    Driesman, Adam
    Kaplan, Daniel
    Feng, James E.
    Waren, Daniel P.
    Vigdorchik, Jonathan
    Meere, Patrick
    Fernandez-Madrid, Ivan
    Slover, James
    Macaulay, William
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (08): : 1662 - 1666
  • [9] Does obesity affect patient-reported outcomes following total knee arthroplasty?
    Baghbani-Naghadehi, Fatemeh
    Armijo-Olivo, Susan
    Prado, Carla M.
    Gramlich, Leah
    Woodhouse, Linda J.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [10] Does obesity affect patient-reported outcomes following total knee arthroplasty?
    Fatemeh Baghbani-Naghadehi
    Susan Armijo-Olivo
    Carla M. Prado
    Leah Gramlich
    Linda J. Woodhouse
    [J]. BMC Musculoskeletal Disorders, 23