Constellation-X Spectroscopy X-ray telescope optical assembly pathfinder image error budget and performance prediction

被引:7
|
作者
Podgorski, WA
Bookbinder, J
Content, D
Davis, W
Freeman, M
Hair, J
Owens, S
Petre, R
Reid, P
Saha, T
Stewart, J
Zhang, W
机构
关键词
X-ray optics; optical alignment; Constellation-X; Spectroscopy X-ray telescope; centroid detector assembly;
D O I
10.1117/12.509487
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Constellation-X mission is a follow-on to the current Chandra and XMM missions. It will place in orbit an array of four X-ray telescopes that Will work in unison, having a substantial increase in effective area, energy resolution, and energy bandpass over current missions. To accomplish these ambitious increases new optics technologies must be exploited. The primary instrument for the mission is the Spectroscopy X-Ray Telescope (SXT), which covers the 0.21 to 10 keV band with a combination of two x-ray detectors: a reflection grating spectrometer with CCD readout and a microcalorimeter. Mission requirements are an effective area of 15,000 cm(2) near 1 keV and a 15 arc-sec (BPD) image resolution with a goal of 5 arc-sec. The Constellation-X SXT uses a segmented design with lightweight replicated optics. A technology development program is being pursued with the intent of demonstrating technical readiness prior to the program new start. Key elements of the program include the replication of the optical elements, assembly and alignment of the optics into a complete mirror assembly and demonstration of production techniques needed for fabrication of multiple units. These elements will be demonstrated in a series of engineering development and prototype optical assemblies which are increasingly flight-like. In this paper we present image angular resolution error budgets for the SXT and for the Optical Assembly Pathfinder #2 (OAP2), the first of engineering development units intended to be tested in x-rays. We describe OAP2 image error sources and performance analyses made to assess error sensitivities. Finally we present an overall prediction of as-tested imaging performance in the x-ray test facility.
引用
收藏
页码:318 / 333
页数:16
相关论文
共 50 条
  • [1] Constellation-X Spectroscopy X-Ray Telescope assembly and alignment
    Podgorski, WA
    Content, D
    Glenn, P
    Hair, J
    Petre, R
    Saha, T
    Schattenburg, M
    Stewart, J
    Zhang, W
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 491 - 502
  • [2] The Constellation-X Spectroscopy X-ray Telescope
    Petre, R
    Content, D
    Lehan, J
    O'Dell, S
    Owens, S
    Podgorsky, W
    Stewart, J
    Zhang, W
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 505 - 514
  • [3] Constellation-X spectroscopy X-ray telescope (SXT)
    Petre, R
    Zhang, WW
    Content, DA
    Saha, TT
    Stewart, J
    Hair, JH
    Nguyen, D
    Podgorski, WA
    Davis, WR
    Freeman, MD
    Cohen, LBM
    Schattenburg, ML
    Heilmann, RK
    Sun, YX
    Forest, C
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 433 - 440
  • [4] Optical metrology for the segmented optics on the Constellation-X Spectroscopy X-ray telescope
    Content, D
    Colella, D
    Hadjimichael, T
    Lehan, JP
    McMann, J
    Reid, P
    Saha, T
    Zhang, W
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 272 - 282
  • [5] Technology Development for the Constellation-X Spectroscopy X-Ray Telescope
    Petre, Robert
    Lehan, John
    O'Dell, Stephen
    Owens, Scott
    Reid, Paul B.
    Saha, Timo
    Stewart, Jeff
    Jones, William D.
    Zhang, William
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY II, 2005, 5900
  • [6] Constellation-X spectroscopy x-ray telescope segmented optic assembly and alignment implementation
    Hair, JH
    Stewart, JW
    Petre, R
    Zhang, WW
    Content, DA
    Saha, TT
    Podgorski, WA
    Glenn, P
    Schattenberg, ML
    Heilmann, RK
    Sun, YX
    Nanan, G
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 696 - 707
  • [7] Recent progress on the Constellation-X spectroscopy X-ray telescope (SXT)
    Petre, R
    Content, D
    O'Dell, S
    Owens, S
    Podgorsky, W
    Stewart, J
    Saha, T
    Zhang, W
    OPTICS FOR EUV, X-RAY AND GAMMA-RAY ASTRONOMY, 2004, 5168 : 196 - 206
  • [8] Testing of the mirrors for the Constellation-X spectroscopy x-ray telescope with a refractive null
    Lehan, J. P.
    Hadjimichael, T.
    Skocik, C.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY III, 2007, 6688
  • [9] Optical metrology for the segmented optics on the Constellation-X Soft X-ray telescope
    Content, D
    Colella, D
    Fleetwood, C
    Hadjimichael, T
    Saha, T
    Wright, G
    Zhang, W
    OPTICS FOR EUV, X-RAY AND GAMMA-RAY ASTRONOMY, 2004, 5168 : 207 - 218
  • [10] Technology development for the Constellation-X hard X-ray telescope
    Harrison, FA
    Cook, WR
    Christensen, FE
    Citterio, O
    Craig, WW
    Gehrels, N
    Gorenstein, P
    Grindlay, JE
    Hailey, CJ
    Kroeger, RA
    Kuneida, H
    Pareschi, G
    Parsons, AM
    Petre, R
    Romaine, SE
    Ramsey, BD
    Tueller, J
    Ulmer, M
    Weisskopf, MC
    Windt, DW
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 104 - 111