Endovascular treatment of aortic aneurysm using the Chuter device

被引:1
|
作者
Chuter, TAM [1 ]
Reilly, LM [1 ]
Canto, C [1 ]
Gordon, R [1 ]
Jean-Claude, J [1 ]
Wall, S [1 ]
Messina, LM [1 ]
机构
[1] Univ Calif San Francisco, Dept Surg, San Francisco, CA 94143 USA
关键词
endovascular; aortic aneurysm; graft; stent;
D O I
10.1055/s-2008-1057058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article assesses a system of endovascular aneurysm repair and determines its potential role in the management of abdominal aortic aneurysm (AAA). The prosthesis was a combination of woven polyester fabric and stainless steel Gianturco Z-stents. Straight (aorto-aortic), tapered (aorto-uniiliac), and bifurcated (aorto-biiliac) stent grafts have all evolved, together with the delivery systems, the patient selection criteria, and the method of insertion, since these devices were first introduced in 1991. Currently, 70% of patients are considered to have the anatomic substrate for endovascular aneurysm repair. All stent-graft implantations were performed in the operating room. Preoperative assessment and postoperative follow-up were based mainly on contrast- enhanced CT, which was performed at 3 days, 3 months, 6 months, and 12 months following repair, if the initial CT showed endoleak, CT was repeated at 2 weeks. Persistent leak at 2 weeks was investigated angiographically as the basis for endovascular intervention, following which CT was repeated again. The results of the most recent (US) experience are as follows. Between June 1996 and September 1997, 46 high-risk patients underwent elective endovascular repair of AAA under an FDA protocol. Aorto-uniiliac stent grafts were used in 38 and aorto-aortic stent grafts in the remainder. The operating time was 190 +/- 71 min (mean + standard deviation), estimated blood loss was 303 +/- 402 ml, and contrast volume was 153 +/- 70 ml. The time from operation to resumption of a normal diet was 0.58 +/- 0.58 days, to ambulation was 1.17 +/- 0.8 days, and to discharge was 3.42 +/- 1.51 days. Six patients had an endoleak on the initial CT, but only 1 of these had leakage 1 month after operation. There were no deaths and no conversions to open repair. Endovascular aneurysm re pair with this system is safe and effective in the short to medium term.
引用
收藏
页码:55 / 61
页数:7
相关论文
共 50 条
  • [1] Endovascular abdominal aortic aneurysm treatment: device-specific outcomes
    Nevelsteen, A
    Maleux, G
    JOURNAL OF CARDIOVASCULAR SURGERY, 2004, 45 (04): : 307 - 319
  • [2] Endovascular exclusion of a saccular aortic aneurysm using a septal occluder device
    Bornak, Arash
    Milner, Ross
    JOURNAL OF VASCULAR SURGERY, 2011, 53 (04) : 1097 - 1099
  • [3] Endovascular treatment of abdominal aortic aneurysm
    Valdés, F
    Seitz, J
    Fava, M
    Kramer, A
    Mertens, R
    Espíndola, M
    Canessa, R
    Sacco, C
    Vergara, J
    Loyola, S
    Ríos, G
    Soffia, P
    REVISTA MEDICA DE CHILE, 1998, 126 (10) : 1206 - 1215
  • [4] Endovascular treatment of the abdominal aortic aneurysm
    Alvarez Garcia, B.
    Gutierrez Alonso, V.
    Del Rio Sola, L.
    Riera de Cubas, L.
    Fernandez Valenzuela, V.
    Ros Die, E.
    Martin Pedrosa, M.
    ANGIOLOGIA, 2011, 63 (04): : 164 - 177
  • [5] Endovascular treatment of abdominal aortic aneurysm
    Gorham, TJ
    Taylor, J
    Raptis, S
    BRITISH JOURNAL OF SURGERY, 2004, 91 (07) : 815 - 827
  • [6] Rescue of failed endovascular aortic aneurysm repair using the fenestrated Anaconda device
    Falkensammer, Juergen
    Taher, Fadi
    Uhlmann, Miriam
    Hirsch, Kornelia
    Strassegger, Johannes
    Assadian, Afshin
    JOURNAL OF VASCULAR SURGERY, 2017, 66 (05) : 1334 - 1339
  • [7] Endovascular Treatment of an Abdominal Aortic FALSE Aneurysm with a Very Narrow Distal Aorta and Aortic Lumen Using an Iliac Branch Device
    Gemayel, Gino
    ANNALS OF VASCULAR SURGERY, 2020, 69 : 452.e1 - 452.e4
  • [8] Endovascular Treatment for Inflammatory Abdominal Aortic Aneurysm
    Lee, Han Cheol
    Han, In Sub
    Lee, Hye Won
    Oh, Jun-Hyok
    Cha, Kwang Soo
    Hong, Taeg Jong
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (17) : S364 - S365
  • [9] Endovascular treatment for ruptured abdominal aortic aneurysm
    Badger, Stephen
    Bedenis, Rachel
    Blair, Paul H.
    Ellis, Peter
    Kee, Frank
    Harkin, Denis W.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2014, (07):
  • [10] Endovascular treatment for ruptured abdominal aortic aneurysm
    Badger, Stephen
    Forster, Rachel
    Blair, Paul H.
    Ellis, Peter
    Kee, Frank
    Harkin, Denis W.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (05):