Assessment of coregistration of PET H215O images in the abdomen using digital phantoms

被引:0
|
作者
Livieratos, L [1 ]
Meikle, SR [1 ]
Matthews, JC [1 ]
Bailey, DL [1 ]
Jones, T [1 ]
Price, P [1 ]
机构
[1] Hammersmith Hosp, MRC, Cyclotron Unit, London W12 0HS, England
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The aim of this study was to investigate the performance of PET-to-PET coregistration of abdominal (H2O)-O-15 blood flow images from different sessions (before and after anti-cdancer treatment) on the same subject. Due to the application-specific nature of image registration methodology, the use of preexisting techniques for new applications requires validation. A quantitative approach was developed based on the Zubal segmented human anatomical phantom [4] in conjunction with blood flow biodistribution data to simulate the activity distribution of a typical PET flow study. Known rotations and translations were applied to the resulting flow software phantom. Poisson noise and spatial resolution of the PET scanner were included in the sinograms created by forward-projection and the reconstructed images were coregistered against a non-transformed reference image using three existing methods: minimisation of standard deviation in the pixel ratio (SPR) [1], multi-resolution maximisation of mutual information (MMI) [2] and K-means variance minimisation (CVM) [3]. Assessment based on the transformation matrices shows comparable performance in the range of the transformations assessed (0-15 degrees rotations, 0-15 pixels translations). Assessment based on correlation, residual image and ROI-based results suggest an advantage of MMI for the specific application considered.
引用
收藏
页码:1175 / 1178
页数:4
相关论文
共 50 条
  • [1] ICA Based Automatic Segmentation of Dynamic H215O Cardiac PET Images
    Margadan-Mendez, Margarita
    Juslin, Anu
    Nesterov, Sergey V.
    Kalliokoski, Kari
    Knuuti, Juhani
    Ruotsalainen, Ulla
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (03): : 795 - 802
  • [2] Measurement of perfusion in NSCLC using H215O and PET.
    Hoekstra, CJ
    Stroobants, SG
    Hoekstra, OS
    Smit, EF
    Vansteenkiste, JF
    Lammertsma, AA
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 30P - 31P
  • [3] Investigating the Premonitory Phase of Migraine with H215O PET
    Maniyar, F. H.
    Sprenger, T.
    Schankin, C.
    Monteith, T.
    Goadsby, P. J.
    [J]. CEPHALALGIA, 2013, 33 (S8) : 12 - 12
  • [4] H215O PET responses to deep brain stimulation
    Montgomery, Erwin B., Jr.
    [J]. BRAIN STIMULATION, 2012, 5 (04) : 657 - 659
  • [5] Noise reduction of parametric images of myocardial blood flow by filtering H215O dynamic PET images using wavelet transform
    Chung, SH
    Lee, JS
    Lee, DS
    Park, KS
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1341 - 1343
  • [6] Mapping of local renal blood flow with PET and H215O
    Alpert, NM
    Rabito, CA
    Correia, DJA
    Babich, JW
    Littman, BH
    Tompkins, RG
    Rubin, NT
    Rubin, RH
    Fischman, AJ
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (04) : 470 - 475
  • [7] Unconscious perception and retrieval of faces imaged with H215O PET
    Nagy, E. Turi
    Henke, K.
    Weber, B.
    Berthold, T.
    Buck, A.
    [J]. PERCEPTION, 1999, 28 : 54 - 54
  • [8] Measurement of cerebral blood flow with H215O PET/MRI
    Okazawa, H.
    Tsujikawa, T.
    Higashino, Y.
    Arishima, H.
    Mori, T.
    Kikuta, K. -I.
    Kiyono, Y.
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 : 211 - 211
  • [9] Hippocampal function in memory studied with H215O PET.
    Buck, A
    Henke, K
    Weber, B
    Kneifel, S
    Berthold, T
    Wieser, HG
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 111P - 111P
  • [10] Automatic generation of absolute myocardial blood flow images using H215O and a clinical PET-CT scanner
    Harms, Hendrik
    Knaapen, Paul
    de Haan, Stefan
    Lammertsma, Adriaan
    Lubberink, Mark
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51