Reduction of aberrant aortic haemodynamics following aortic root replacement with a mechanical valved conduit

被引:20
|
作者
Keller, Eric J. [1 ]
Malaisrie, S. Chris [2 ]
Kruse, Jane [2 ]
McCarthy, Patrick M. [2 ]
Carr, James C. [1 ]
Markl, Michael [1 ,3 ]
Barker, Alex J. [1 ,3 ]
Collins, Jeremy D. [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Div Surg Cardiac Surg, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
关键词
Aortic valve replacement; Mechanical heart valve prosthesis; Magnetic resonance imaging; HEALTHY-VOLUNTEERS; FLOW PATTERNS; PROSTHESES; IMPACT;
D O I
10.1093/icvts/ivw173
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: Previous work suggests that aortic root and valve prostheses alter blood flow patterns in the ascending aorta, creating aberrant haemodynamics compared with those of healthy volunteers. Various valve designs have been proposed to better restore physiological haemodynamics. In this study, magnetic resonance imaging (MRI) was used to non-invasively assess three-dimensional (3D) ascending aortic haemodynamics after aortic root replacement (ARR) with a mechanical valved conduit postulated to create less turbulent blood flow. METHODS: Ten patients (40 +/- 9 years) underwent transthoracic echocardiography and contrast-enhanced multidimensional four-dimensional (4D) flow MRI at 1.5 T after ARR with an On-X mechanical valved conduit. Preoperative 4D flow MRI was available in 7 patients. Ten age- and gender-matched healthy volunteers (42 +/- 13 years) were also analysed to characterize physiological flow. The presence of vortex/helix formation was graded by two blinded observers. Peak transvalvular pressure gradients were computed using the simplified Bernoulli equation. Patients' postoperative pressure gradients and helicity/vorticity grades were compared with preoperative gradients and those from healthy volunteers. RESULTS: Intra- and interobserver ratings showed good agreement (kappa = 0.93, P < 0.01 and kappa = 0.84, P < 0.01, respectively). Highly helical and/or vortical flow was observed in all patients preoperatively, which was significantly reduced postoperatively (P < 0.01 and < 0.01, respectively), restoring similar flow patterns similar to those seen in volunteers (P = 0.56 and 0.56). Peak transvalvular pressure gradients (Delta P) were also significantly reduced [43 +/- 21 vs 12 +/- 7 mmHg, P < 0.05 (Echo); 48 +/- 22 vs 16 +/- 9 mmHg, P < 0.05 (MRI)], but remained significantly higher than those of volunteers (6 +/- 1 mmHg, P < 0.01). CONCLUSIONS: Preliminary evidence suggests that ARR with an On-X mechanical valve significantly reduces aberrant aortic haemodynamics, producing flow patterns that resemble those in healthy volunteers.
引用
收藏
页码:416 / 423
页数:8
相关论文
共 50 条
  • [1] Aortic Valve Reimplantation or Aortic Root Replacement With a Valved Conduit?
    David, Tirone E.
    ANNALS OF THORACIC SURGERY, 2024, 117 (01): : 76 - 77
  • [2] Aortic Root Replacement With Autologous Pericardium Valved Conduit
    Seese, Laura
    Yoon, Pyongsoo
    Morell, Victor O.
    Chu, Danny
    ANNALS OF THORACIC SURGERY, 2022, 113 (03): : E227 - E229
  • [3] Aortic root replacement with a valved conduit containing a stented xenograft
    Gatti, Giuseppe
    Benussi, Bernardo
    Pappalardo, Aniello
    Zingone, Bartoto
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (04) : 740 - 741
  • [4] In Situ Composition of Valved Conduit for Complex Reoperative Aortic Root Replacement
    Vandenberge, John
    Kurlansky, Paul
    Takeda, Koji
    Yamabe, Tsuyoshi
    Sanchez, Joseph
    Naka, Yoshifumi
    Takayama, Hiroo
    ANNALS OF THORACIC SURGERY, 2020, 110 (06): : E549 - E550
  • [5] In-Human Implantation of a Novel Biologic Valved Conduit for Aortic Root Replacement
    DeRoo, Scott C.
    Desai, Nimesh
    Grimm, Joshua C.
    Cannon, Brittany
    Bavaria, Joseph E.
    ANNALS OF THORACIC SURGERY, 2022, 113 (01): : E21 - E24
  • [6] Replacement of the ascending aorta, aortic root, and valve with a novel stentless valved conduit
    Lau, Kelvin K. W.
    Bochenek-Klimczyk, Krystyna
    Galinanes, Manuel
    Sosnowski, Andrzej W.
    ANNALS OF THORACIC SURGERY, 2008, 86 (01): : 278 - 281
  • [7] Early Hemodynamic Performance of the BioValsalva Valved Conduit after Aortic Root Replacement
    Badiu, Catalin Constantin
    Deutsch, Marcus-Andre
    Bleiziffer, Sabine
    Krane, Markus
    Hettich, Ina
    Voss, Bernhard
    Mazzitelli, Domenico
    Lange, Ruediger
    JOURNAL OF HEART VALVE DISEASE, 2014, 23 (01): : 97 - 104
  • [8] Totally biological composite aortic stentless valved conduit for aortic root replacement: 10-year experience
    Galinanes, Manuel
    Meduoye, Ayo
    Ferreira, Ignacio
    Sosnowski, Andrzej
    JOURNAL OF CARDIOTHORACIC SURGERY, 2011, 6
  • [9] Aortic Root Replacement with a Stented Bioprosthetic Valved Conduit: Mid-Term Results
    Gatti, Giuseppe
    Dell'Angela, Luca
    Pinamonti, Bruno
    Moncada, Alessandro
    Minati, Alessandro
    Benussi, Bernardo
    Sinagra, Gianfranco
    Pappalardo, Aniello
    JOURNAL OF HEART VALVE DISEASE, 2013, 22 (04): : 500 - 508
  • [10] Totally biological composite aortic stentless valved conduit for aortic root replacement: 10-year experience
    Manuel Galiñanes
    Ayo Meduoye
    Ignacio Ferreira
    Andrzej Sosnowski
    Journal of Cardiothoracic Surgery, 6