Cardiac implantable electronic device infections: Presentation, management, and patient outcomes

被引:194
|
作者
Tarakji, Khaldoun G. [1 ]
Chan, Eric J. [4 ]
Cantillon, Daniel J. [1 ]
Doonan, Aaron L. [5 ]
Hu, Tingfei [3 ]
Schmitt, Steven
Fraser, Thomas G. [2 ]
Kim, Alice [2 ]
Gordon, Steven M. [2 ]
Wilkoff, Bruce L. [1 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Infect Dis, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Quantitat Hlth Sci, Cleveland, OH 44195 USA
[4] Univ Missouri, Dept Cardiovasc Med, Columbia, MO USA
[5] Univ Minnesota, Dept Cardiovasc Med, Minneapolis, MN USA
关键词
Complication; Defibrillator; Electronic device; Extraction; Infection; Pacemaker; CARDIOVERTER-DEFIBRILLATORS; PERMANENT PACEMAKER; ANTIBIOTIC-PROPHYLAXIS; SYSTEMIC INFECTION; ENDOCARDITIS; RATES;
D O I
10.1016/j.hrthm.2010.05.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Indications for cardiac implantable electronic devices (CIEDs) are increasing. Although CIED infections occur infrequently, the impact of this outcome is expected to be substantial. OBJECTIVE The purpose of this study was to the evaluate the outcome of patients undergoing removal of infected CIEDs. METHODS A retrospective study was conducted of all patients with proven or suspected infected CIEDs who were referred to the Cleveland Clinic for system removal from January 2002 through March 2007. RESULTS A total of 412 patients (age 68 +/- 15 years) were included in the study. The majority of patients (241 [59%]) presented with localized infection involving the device pocket. The remaining 171 patients (41%) presented with endovascular infection but no evidence of inflammation of the device pocket. Of the total 414 pathogens isolated, 366 (88%) were aerobic gram-positive organisms, of which 90% were Staphylococcus species, and almost half of these were methicillin resistant. In-hospital mortality was 4.6% (19 patients). Only 2 deaths were extraction related. One-year mortality was 17%. Among the total cohort, 8 (1.9%) patients had relapsing infection within the first year. Among patients who had device replacement during the same hospitalization, 6 (2.6%) had relapsing infections within 1 year of reimplantation; 5 of these patients had systemic symptoms and were bacteremic upon initial presentation. CONCLUSION CIED infections are most often caused by Staphylococcus species, half of which are methicillin resistant. Percutaneous lead and device removal along with antibiotic therapy are effective as primary interventions. The overall relapse rate is 1.9%, and the relapse rate among patients who had reimplantation during the same hospitalization is 2.6%.
引用
收藏
页码:1043 / 1047
页数:5
相关论文
共 50 条
  • [1] Surgical management of cardiac implantable electronic device infections
    Koutentakis, Michael
    Siminelakis, Stavros
    Korantzopoulos, Panagiotis
    Petrou, Alexandra
    Priavali, Eleftheria
    Mpakas, Andreas
    Gesouli, Eleftheria
    Apostolakis, Eleftheria
    Tsakiridis, Kosmas
    Zarogoulidis, Paul
    Katsikogiannis, Nikolaos
    Kougioumtzi, Ioanna
    Machairiotis, Nikolaos
    Tsiouda, Theodora
    Zarogoulidis, Konstantinos
    [J]. JOURNAL OF THORACIC DISEASE, 2014, 6 : S173 - S179
  • [2] Cardiac implantable electronic devices and bloodstream infections: management and outcomes
    Ozkartal, Tardu
    Demarchi, Andrea
    Conte, Giulio
    Pongan, Damiano
    Klersy, Catherine
    Caputo, Maria Luce
    Bergonti, Marco
    Bernasconi, Enos
    Gaia, Valeria
    Granger, Christopher B.
    Auricchio, Angelo
    [J]. EUROPEAN HEART JOURNAL, 2024, 45 (14) : 1269 - 1277
  • [3] Cost and Outcomes of Implantable Cardiac Electronic Device Infections in Victoria, Australia
    Roder, Christine
    Gunjaca, Vanika
    Otome, Ohide
    Gwini, Stella May
    Athan, Eugene
    [J]. HEART LUNG AND CIRCULATION, 2020, 29 (07): : E140 - E146
  • [4] Anaesthetic management of a pregnant patient with cardiac implantable electronic device
    Nair, U.
    Aggarwal, V.
    Jain, A.
    [J]. ANAESTHESIA, 2018, 73 : 84 - 84
  • [5] Clinical Presentation and Outcomes of Cardiovascular Implantable Electronic Device Infections in Hemodialysis Patients
    Hickson, LaTonya J.
    Gooden, Janelle Y.
    Le, Katherine Y.
    Baddour, Larry M.
    Friedman, Paul A.
    Hayes, David L.
    Wilson, Walter R.
    Steckelberg, James M.
    Sohail, M. Rizwan
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 2014, 64 (01) : 104 - 110
  • [6] Management of Cardiac Electronic Device Infections: Challenges and Outcomes
    Kirkfeldt, Rikke Esberg
    Johansen, Jens Brock
    Nielsen, Jens Cosedis
    [J]. ARRHYTHMIA & ELECTROPHYSIOLOGY REVIEW, 2016, 5 (03) : 183 - 187
  • [7] Current trends in the management of cardiac implantable electronic device (CIED) infections
    Durante-Mangoni, Emanuele
    Mattucci, Irene
    Agrusta, Federica
    Tripodi, Marie-Francoise
    Utili, Riccardo
    [J]. INTERNAL AND EMERGENCY MEDICINE, 2013, 8 (06) : 465 - 476
  • [8] Current trends in the management of cardiac implantable electronic device (CIED) infections
    Emanuele Durante-Mangoni
    Irene Mattucci
    Federica Agrusta
    Marie-Françoise Tripodi
    Riccardo Utili
    [J]. Internal and Emergency Medicine, 2013, 8 : 465 - 476
  • [9] Microbiology of cardiac implantable electronic device infections
    Bongiorni, Maria Grazia
    Tascini, Carlo
    Tagliaferri, Enrico
    Di Cori, Andrea
    Soldati, Ezio
    Leonildi, Alessandro
    Zucchelli, Giulio
    Ciullo, Ilaria
    Menichetti, Francesco
    [J]. EUROPACE, 2012, 14 (09): : 1334 - 1339
  • [10] Preventing cardiac implantable electronic device infections
    Padfield, Gareth J.
    Steinberg, Christian
    Bennett, Matthew T.
    Chakrabarti, Santabhanu
    Deyell, Marc W.
    Bashir, Jamil
    Krahn, Andrew D.
    [J]. HEART RHYTHM, 2015, 12 (11) : 2344 - 2356