Transcutaneous Electrical Nerve Stimulation in Rodent Models of Neuropathic Pain: A Meta-Analysis

被引:6
|
作者
Huang, Jiapeng [1 ,2 ,3 ]
Yang, Chunlan [1 ,2 ,3 ]
Zhao, Kehong [1 ,2 ,3 ]
Zhao, Ziqi [1 ,2 ,3 ]
Chen, Yin [1 ,2 ,3 ]
Wang, Tingting [1 ,2 ,3 ]
Qu, Yun [1 ,2 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, Dept Rehabil Med, Chengdu, Peoples R China
[2] Sichuan Univ, West China Hosp, Key Lab Rehabil Med Sichuan Prov, Chengdu, Peoples R China
[3] Sichuan Univ, West China Hosp, Res Inst Rehabil Med, Res Lab Neurorehabil, Chengdu, Peoples R China
关键词
transcutaneous electrical nerve stimulation; neuropathic pain; animal studies; pain models; meta-analysis; HORN NEUROTRANSMITTER CONTENT; MECHANICAL ALLODYNIA; ENDOGENOUS OPIOIDS; RAT MODEL; FREQUENCY; TENS; HYPERALGESIA; NOCICEPTION; ACTIVATION; MANAGEMENT;
D O I
10.3389/fnins.2022.831413
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Transcutaneous electrical nerve stimulation (TENS) is a non-invasive therapeutic intervention that is typically used for many years to treat chronic pain in patients who are refractory to pain medications. However, evidence of the efficacy of TENS treatment for neuropathic pain is lacking in humans. To further understand the efficacy of TENS under various intervention conditions and illuminate the current circumstance and future research directions, we systematically reviewed animal studies investigating the efficacy of TENS in relieving pain in neuropathic pain rodent models. We searched the Cochrane Library, EMBASE, MEDLINE (via PubMed), and Web of Science and identified 11 studies. Two meta-analyses were performed. The first meta-analysis showed that a single TENS treatment was capable of temporarily ameliorating neuropathic pain when compared to control groups with a significant effect (standardized mean difference: 1.54; 95% CI: 0.65, 2.42; p = 0.0007; I-2 = 58%). Significant temporary alleviation in neuropathic pain intensity was also observed in the meta-analysis of repetitive TENS (standardized mean difference: 0.85; 95% CI: 0.31, 1.40; p = 0.002; I-2 = 75%). Subgroup analysis showed no effect of the timing of the application of TENS (test for subgroup difference, p = 0.47). Leave-one-out sensitivity analyses suggested that no single study had an outsized effect on the pooled estimates, which may partly prove the robustness of these findings. Other stratified analyses were prevented by the insufficient number of included studies. Overall, current data suggest that TENS might be a promising therapy to ameliorate neuropathic pain. However, the high risk of bias in the included studies suggests that cautions must be considered when interpreting these findings and it is not reasonable to directly generalize the results obtained from animal studies to clinical practice. Future studies should pay more attention to improving the quality of study design and reporting, thereby facilitating the understanding of mechanisms underlying TENS treatment, reducing more potentially unsuccessful clinical trials, and optimizing the efficacy of TENS for people with neuropathic pain.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Transcutaneous electrical nerve stimulation for neuropathic pain
    Cheing, GLY
    Luk, MLM
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2005, 30B (01): : 50 - 55
  • [2] Meta-analysis of transcutaneous electrical nerve stimulation for relief of spinal pain
    Resende, L.
    Merriwether, E.
    Rampazo, E. P.
    Dailey, D.
    Embree, J.
    Deberg, J.
    Liebano, R. E.
    Sluka, K. A.
    [J]. EUROPEAN JOURNAL OF PAIN, 2018, 22 (04) : 663 - 678
  • [3] Differential Effects of Subcutaneous Electrical Stimulation (SQS) and Transcutaneous Electrical Nerve Stimulation (TENS) in Rodent Models of Chronic Neuropathic or Inflammatory Pain
    Vera-Portocarrero, Louis P.
    Cordero, Toni
    Billstrom, Tina
    Swearingen, Kim
    Wacnik, Paul W.
    Johanek, Lisa M.
    [J]. NEUROMODULATION, 2013, 16 (04): : 328 - 335
  • [4] Transcutaneous electrical nerve stimulation (TENS) in neuropathic pain
    Disselhoff, B
    [J]. PAIN CLINIC, 2000, 12 (02): : 145 - 146
  • [5] Transcutaneous electrical nerve stimulation (TENS) for neuropathic pain in adults
    Gibson, William
    Wand, Benedict M.
    O'Connell, Neil E.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2017, (09):
  • [6] Efficacy of the transcutaneous electrical nerve stimulation for the treatment of chronic low back pain - A meta-analysis
    Brosseau, L
    Milne, S
    Robinson, V
    Marchand, S
    Shea, B
    Wells, G
    Tugwell, P
    [J]. SPINE, 2002, 27 (06) : 596 - 603
  • [7] Literature Review and Meta-Analysis of Transcutaneous Electrical Nerve Stimulation in Treating Chronic Back Pain
    Wu, Lien-Chen
    Weng, Pei-Wei
    Chen, Chia-Hsien
    Huang, Yi-You
    Tsuang, Yang-Hwei
    Chiang, Chang-Jung
    [J]. REGIONAL ANESTHESIA AND PAIN MEDICINE, 2018, 43 (04) : 425 - 433
  • [8] Transcutaneous electrical stimulation in neck pain: A systematic review and meta-analysis
    Rampazo, Erika Patricia
    Santi Martignago, Cintia Cristina
    de Noronha, Marcos
    Liebano, Richard Eloin
    [J]. EUROPEAN JOURNAL OF PAIN, 2022, 26 (01) : 18 - 42
  • [9] Effects of Transcutaneous Electrical Nerve Stimulation on Chronic Pelvic Pain in Women: A Systematic Review and Meta-Analysis
    Babazadeh-Zavieh, Seyedeh Saeideh
    Tajali, Siamak Bashardoust
    Haeri, Seyed Mohammad Jafar
    Shamsi, Amirhossein
    [J]. COMPLEMENTARY MEDICINE RESEARCH, 2023, 30 (02) : 161 - 173
  • [10] Efficacy of transcutaneous electrical nerve stimulation in people with pain after spinal cord injury: a meta-analysis
    Ye Yang
    Yun Tang
    Huiqing Qin
    Jianwen Xu
    [J]. Spinal Cord, 2022, 60 : 375 - 381